SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hagman Mattias) srt2:(2000-2004)"

Sökning: WFRF:(Hagman Mattias) > (2000-2004)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Hagman, Mattias, et al. (författare)
  • Correlated evolution of conspicuous colouration and body size in the poison frog family Dendrobatidae
  • 2003
  • Ingår i: Evolution. - : Wiley. - 0014-3820 .- 1558-5646. ; 57:12, s. 2904-2910
  • Tidskriftsartikel (refereegranskat)abstract
    • Conspicuous coloration is often used in combination with chemical defenses to deter predators from attacking. Experimental studies have shown that the avoidance inducing effect of conspicuous prey coloration increases with increasing size of pattern elements and with increasing body size. Here we use a comparative approach to test the prediction from these findings, namely that conspicuous coloration will evolve in tandem with body size. In our analysis, we use a previously published mitochondrial DNA-based phylogeny and comparative analysis of independent contrasts to examine if evolutionary shifts in color pattern have been associated with evolutionary changes in body size in aposematic poison frogs (Anura: Dendrobatidae). Information on body size (snout to vent length) and coloration were obtained from the literature. Two different measures of conspicuousness were used, one based on rankings by human observers and the other based on computer analysis of digitized photographs. The results from comparative analyses using either measure of coloration indicated that avoidance inducing coloration and body size have evolved in concert in poison frogs. Results from reconstruction of character change further indicate that the correlated evolution of size and coloration has involved changes in both directions within each of the different clades of the phylogenetic tree. This finding is consistent with the hypothesis that selection imposed by visually guided predators has promoted the evolution of larger body size in species with conspicuous coloration, or enhanced evolution of conspicuous coloration in larger species.
  •  
4.
  • Hagman, Mattias (författare)
  • Costa Rica - den rika kusten
  • 2000
  • Ingår i: Terrariet. ; 7:4, s. 3-12
  • Tidskriftsartikel (populärvet., debatt m.m.)
  •  
5.
  •  
6.
  • Hagman, Mattias (författare)
  • Terrarieteknik och växter
  • 2001
  • Ingår i: Terrariet. ; 8:10, s. 3-12
  • Tidskriftsartikel (populärvet., debatt m.m.)
  •  
7.
  • Wiberg, Kent, et al. (författare)
  • Peak purity determination with principal component analysis of high-performance liquid chromatography-diode array detection data
  • 2004
  • Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1029:1-2, s. 13-20
  • Tidskriftsartikel (refereegranskat)abstract
    • A method is proposed for the determination of chromatographic peak purity by means of principal component analysis (PCA) of high-performance liquid chromatography with diode array detection (HPLC–DAD) data. The method is exemplified with analysis of binary mixtures of lidocaine and prilocaine with different levels of separation. Lidocaine and prilocaine have very similar spectra and the chromatograms used had substantial peak overlap. The samples analysed contained a constant amount of lidocaine and a minor amount of prilocaine (0.02–2 conc.%) and hence the focus was on determining the purity of the lidocaine peak in the presence of much smaller levels of prilocaine. The peak purity determination was made by examination of relative observation residuals, scores and loadings from the PCA decomposition of DAD data over a chromatographic peak. As a reference method, the functions for peak purity analysis in the chromatographic data system used (Chromeleon) were applied. The PCA method showed good results at the same level as the detection limit of baseline-separated prilocaine, outperforming the methods in Chromeleon by a factor of ten. There is a discussion of the interpretation of the result, with some comparisons with evolving factor analysis (EFA). The main advantage of the PCA method for determination of peak purity over methods like EFA lies in its simplicity, short time of calculation and ease of use.
  •  
8.
  • Wiberg, Kent, et al. (författare)
  • Use of control sample for estimation of prediction error in multivariate determination of lidocaine solutions with non-column chromatographic diode array UV spectroscopy
  • 2003
  • Ingår i: Journal of Pharmaceutical and Biomedical Analysis. - 0731-7085 .- 1873-264X. ; 33:5, s. 859-869
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate the ability of a control sample, of known content and identity, to diagnose and correct errors in the predictions when the same multivariate calibration model was used for analysis of new samples over time. A calibration set consisting of 16 samples with a known content of lidocaine was analysed and two external test sets, A and B, were used for the validation. Test set A contained 15 samples with different concentrations of lidocaine and test set B contained three samples with different lidocaine content, which were analysed six times in order to obtain a measure of repeatability. The multivariate calibration was done with PLS regression on UV spectra collected between 245 and 290 nm. A representative UV spectrum was exported from the collected DAD files by two methods, average spectrum over the whole file and average spectrum over the sample plug. Test set A was analysed further on another three occasions together with a control sample. The results showed that the control sample could be used to give a diagnosis and estimate of the prediction error. Moreover, the measured prediction error of the control sample could also be used to correct the predictions, thereby reducing the prediction error. Finally, some practical considerations regarding use of the proposed DAD method with a control sample are presented. The procedure suggested could lead to an efficient analytical approach where the same calibration model could be used over time without recalibration, which may be attractive in industrial quality control or screening analysis in pharmaceutical research.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8
Typ av publikation
tidskriftsartikel (8)
Typ av innehåll
populärvet., debatt m.m. (4)
refereegranskat (4)
Författare/redaktör
Hagman, Mattias (6)
Forsman, Anders (2)
Andersson, Mattias (2)
Hagman, Anders (2)
Jacobsson, Sven P (2)
Wiberg, Kent (2)
Lärosäte
Stockholms universitet (7)
Linnéuniversitetet (1)
Språk
Svenska (4)
Engelska (4)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy