SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Harris W.) srt2:(2000-2004)"

Sökning: WFRF:(Harris W.) > (2000-2004)

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abreu, P., et al. (författare)
  • Measurement of the gluon fragmentation function and a comparison of the scaling violation in gluon and quark jets
  • 2000
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 13:4, s. 573-589
  • Tidskriftsartikel (refereegranskat)abstract
    • The fragmentation functions of quarks and gluons are measured in various three-jet topologies in Z decays from the full data set collected with the DELPHI detector at the Z resonance between 1992 and 995. The results at different values of transverse momentum-like scales are compared. A parameterization of the quark and gluon fragmentation functions at a fixed reference scale is given. The quark and gluon fragmentation functions show the predicted pattern of scaling violations. The scaling violation for quark jets as a function of a transverse momentum-like scale is in a good agreement with that observed in lower energy e+e- annihilation experiments. For gluon jets it appears to be significantly stronger. The scale dependences of the gluon and quark fragmentation functions agree with the prediction of the DGLAP evolution equations from which the colour factor ratio CA/CF is measured to be: CA/CF = 2.26 ± 0.09stat. ± 0.06sys. ± 0.12clus.,scale..
  •  
2.
  • Abreu, P., et al. (författare)
  • Study of dimuon production in photon-photon collisions and measurement of QED photon structure functions at LEP
  • 2001
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 19:1, s. 15-28
  • Tidskriftsartikel (refereegranskat)abstract
    • Muon pair production in the process e+e- → e+e- μ+μ- is studied using the data taken at LEP1 (√s ≃ mz) with the DELPHI detector during the years 1992-1995. The corresponding integrated luminosity is 138.5 pb-1. The QED predictions have been tested over the whole Q2 range accessible at LEP1 (from several GeV2/c4 to several hundred GeV2/c4) by comparing experimental distributions with distributions resulting from Monte Carlo simulations using various generators. Selected events are used to extract the leptonic photon structure function Fγ 2. Azimuthal correlations are used to obtain information on additional structure functions, Fγ A and Fγ B, which originate from interference terms of the scattering amplitudes. The measured ratios Fγ A/Fγ 2 and FγB/Fγ 2 are significantly different from zero and consistent with QED predictions.
  •  
3.
  • Abreu, P., et al. (författare)
  • Search for sleptons in e+e- collisions at √s = 183 to 189 GeV
  • 2001
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 19:1, s. 29-42
  • Tidskriftsartikel (refereegranskat)abstract
    • Data taken by the DELPHI experiment at centre-of-mass energies of 183 GeV and 189 GeV with a total integrated luminosity of 212 pb-1 have been used to search for the supersymmetric partners of the electrons, muons, and taus in the context of the Minimal Supersymmetric Standard Model (MSSM). The decay topologies searched for were the direct decay (ℓ̃ → ℓx̃), producing acoplanar lepton pairs plus missing energy, and the cascade decay (ℓ → ℓx̃0 2 → ℓγx̃0 1), producing acoplanar lepton and photon pairs plus missing energy. The observed number of events is in agreement with Standard Model predictions. The 95% CL excluded mass limits for selectrons, smuons and staus are mẽ ≤ 87 GeV/c2, mμ̃ ≤ 80 GeV/c2 and mτ̃ 75 GeV/c2, respectively, for values of μ=-200 GeV/c2 and tanβ=1.5.
  •  
4.
  •  
5.
  • Hillier, Ladeana W, et al. (författare)
  • Sequence and comparative analysis of the chicken genome provide unique perspectives on vertebrate evolution
  • 2004
  • Ingår i: Nature. - 0028-0836 .- 1476-4687. ; 432:7018, s. 695-716
  • Tidskriftsartikel (refereegranskat)abstract
    • We present here a draft genome sequence of the red jungle fowl, Gallus gallus. Because the chicken is a modern descendant of the dinosaurs and the first non-mammalian amniote to have its genome sequenced, the draft sequence of its genome--composed of approximately one billion base pairs of sequence and an estimated 20,000-23,000 genes--provides a new perspective on vertebrate genome evolution, while also improving the annotation of mammalian genomes. For example, the evolutionary distance between chicken and human provides high specificity in detecting functional elements, both non-coding and coding. Notably, many conserved non-coding sequences are far from genes and cannot be assigned to defined functional classes. In coding regions the evolutionary dynamics of protein domains and orthologous groups illustrate processes that distinguish the lineages leading to birds and mammals. The distinctive properties of avian microchromosomes, together with the inferred patterns of conserved synteny, provide additional insights into vertebrate chromosome architecture.
  •  
6.
  •  
7.
  • Bragdon, Charles R, 1959, et al. (författare)
  • Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom
  • 2004
  • Ingår i: J Orthop Res. - : Wiley. - 0736-0266. ; 22:3, s. 659-64
  • Tidskriftsartikel (refereegranskat)abstract
    • Radiostereometric analysis (RSA) has been used extensively to evaluate the magnitude and direction of penetration of the femoral head into the acetabular component of a total hip replacement as a result of polyethylene wear and creep. The accuracy and precision of an RSA study depends on several factors, including the radiographic technique, the analytical software, and the positioning of the tantalum markers. This study had three sequential purposes. First, an in vitro phantom model was used to quantify the accuracy and precision of digital images versus conventional radiography in RSA measurements of penetration of the femoral head into the acetabular shell in a total hip replacement. The Umea RSA software package was used for analysis of both the conventional films, which were digitized at a resolution of 300 DPI, and digital radiographs, which were converted from a DICOM format at a resolution of 218 DPI. Digital radiography was found to be superior. Next, two methods of RSA analysis currently in use for determining femoral head penetration into polyethylene of total joint replacements were compared. Using the phantom model, we compared the Umea RSA system (Biomedical Innovations AB) to the RSA-CMS (RSA Clinical Measurement Solution) and in both cases used the digital radiographs. The Umea RSA system was found to be superior. Finally, two methods of marking the position of the acetabular component with tantalum beads were compared: one in which beads were inserted into previously described towers protruding from the back of the acetabular shell and another in which beads were placed into the peripheral flange of the polyethylene liner using the Umea RSA analysis system of the digital radiographs. The results using the two marker configurations were similar.
  •  
8.
  •  
9.
  • Bragdon, C. R., et al. (författare)
  • Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model
  • 2002
  • Ingår i: Journal of Orthopaedic Research. ; 20:4, s. 688-695
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to develop and testa phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral h cad resulting fro in polyethylene car, This Model was used to Study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which Could simulate progressive. three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using it coordinate Measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 mum The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 mum for the medial direction, 22 mum for the superior direction, 86 mum for the posterior direction and 55 mum for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times. measured 8.4 mum for the medial direction, 5.5 mum for the superior direction. 16.0 mum for the posterior direction. and 13 5 mum for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd, All rights reserved.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy