Sökning: WFRF:(Heidemann Franziska)
> (2018) >
Fenestrated TEVAR U...
Fenestrated TEVAR Using a Guidewire Fixator for Anchoring in Aortic Arch Target Vessels
-
- Koelbel, Tilo (författare)
- Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
-
- Bosaeus, Linus (författare)
- Endovasc Dev AB, Uppsala, Sweden.
-
- Tsilimparis, Nikolaos (författare)
- Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
-
visa fler...
-
- Heidemann, Franziska (författare)
- Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
-
- Rohlffs, Fiona (författare)
- Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany.
-
- Liungman, Krister (författare)
- Uppsala universitet,Institutionen för kirurgiska vetenskaper
-
visa färre...
-
Univ Heart Ctr, German Aort Ctr, Dept Vasc Med, Hamburg, Germany Endovasc Dev AB, Uppsala, Sweden. (creator_code:org_t)
- 2017-11-29
- 2018
- Engelska.
-
Ingår i: Journal of Endovascular Therapy. - : SAGE Publications. - 1526-6028 .- 1545-1550. ; 25:1, s. 40-46
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose:To report a new facilitated method for securing target vessel access during single fenestrated and branched thoracic endovascular repair using a guidewire fixator.Technique: The Liungman Guidewire Fixator (LGF) includes a 0.035-inch guidewire that is fitted with a stopper close to the distal end and a self-expanding anchoring element that is freely movable over the guidewire to the point of the stopper. The technique of using a LGF for anchoring in a target vessel is described in a 75-year-old woman with a 53-mm saccular arch aneurysm. She was treated with a fenestrated Zenith stent-graft that had a catheter-preloaded fenestration for the left subclavian artery (LSA) and a scallop for the left common carotid artery. To avoid through-and-through wire and brachial access, the LGF was used to secure the guidewire in the LSA during stent-graft deployment.Conclusion: The use of an LGF for anchoring in the target LSA during fenestrated arch endografting was feasible and safe.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- aortic aneurysm
- aortic arch
- fenestrated stent-graft
- guidewire fixator
- left subclavian artery
- thoracic aorta
- thoracic endovascular aortic repair
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas