SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Heise T.) srt2:(2015-2019)"

Search: WFRF:(Heise T.) > (2015-2019)

  • Result 1-7 of 7
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Lind, Marcus, 1976, et al. (author)
  • Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections The GOLD Randomized Clinical Trial
  • 2017
  • In: Jama-Journal of the American Medical Association. - : American Medical Association (AMA). - 0098-7484 .- 1538-3598. ; 317:4, s. 379-387
  • Journal article (peer-reviewed)abstract
    • IMPORTANCE The majority of individuals with type 1 diabetes do not meet recommended glycemic targets. OBJECTIVE To evaluate the effects of continuous glucose monitoring in adults with type 1 diabetes treated with multiple daily insulin injections. DESIGN, SETTING, AND PARTICIPANTS Open-label crossover randomized clinical trial conducted in 15 diabetes outpatient clinics in Sweden between February 24, 2014, and June 1, 2016 that included 161 individuals with type 1 diabetes and hemoglobin A(1c) (HbA(1c)) of at least 7.5%(58 mmol/mol) treated with multiple daily insulin injections. INTERVENTIONS Participants were randomized to receive treatment using a continuous glucose monitoring system or conventional treatment for 26 weeks, separated by a washout period of 17 weeks. MAIN OUTCOMES AND MEASURES Difference in HbA(1c) between weeks 26 and 69 for the 2 treatments. Adverse events including severe hypoglycemia were also studied. RESULTS Among 161 randomized participants, mean age was 43.7 years, 45.3% were women, and mean HbA(1c) was 8.6%(70 mmol/mol). A total of 142 participants had follow-up data in both treatment periods. Mean HbA(1c) was 7.92%(63 mmol/mol) during continuous glucose monitoring use and 8.35%(68 mmol/mol) during conventional treatment (mean difference, -0.43% [95% CI, -0.57% to -0.29%] or -4.7 [-6.3 to -3.1 mmol/mol]; P < .001). Of 19 secondary end points comprising psychosocial and various glycemic measures, 6 met the hierarchical testing criteria of statistical significance, favoring continuous glucose monitoring compared with conventional treatment. Five patients in the conventional treatment group and 1 patient in the continuous glucose monitoring group had severe hypoglycemia. During washout when patients used conventional therapy, 7 patients had severe hypoglycemia. CONCLUSIONS AND RELEVANCE Among patients with inadequately controlled type 1 diabetes treated with multiple daily insulin injections, the use of continuous glucose monitoring compared with conventional treatment for 26 weeks resulted in lower HbA(1c). Further research is needed to assess clinical outcomes and longer-term adverse effects.
  •  
3.
  •  
4.
  • Olafsdottir, Arndis, 1978, et al. (author)
  • A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3)
  • 2018
  • In: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 20:4, s. 274-284
  • Journal article (peer-reviewed)abstract
    • Background: To evaluate the effects of continuous glucose monitoring (CGM) on nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with multiple daily insulin injections (MDI); we also evaluated factors related to differences in hypoglycemia confidence in this population. Methods: Evaluations were performed from the GOLD randomized trial, an open-label multicenter crossover randomized clinical trial (n=161) over 69 weeks comparing CGM to self-measurement of blood glucose (SMBG) in persons with type 1 diabetes treated with MDI. Masked CGM and the hypoglycemia confidence questionnaire were used for evaluations. Results: Time with nocturnal hypoglycemia, glucose levels <70mg/dL was reduced by 48% (10.2 vs. 19.6min each night, P<0.001) and glucose levels <54mg/dL by 65%. (3.1 vs. 8.9min, P<0.001). For the corresponding glucose cutoffs, daytime hypoglycemia was reduced by 40% (29 vs. 49min, P<0.001) and 54% (8 vs. 18min., P<0.001), respectively. Compared with SMBG, CGM use improved hypoglycemia-related confidence in social situations (P=0.016) and confidence in more broadly avoiding serious problems due to hypoglycemia (P=0.0020). Persons also reported greater confidence in detecting and responding to decreasing blood glucose levels (thereby avoiding hypoglycemia) during CGM use (P=0.0033) and indicated greater conviction that they could more freely live their lives despite the risk of hypoglycemia (P=0.022). Conclusion: CGM reduced time in both nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with MDI and improved hypoglycemia-related confidence, especially in social situations, thus contributing to greater well-being and quality of life. Trial registration: ClinicalTrials.gov, number NCT02092051.
  •  
5.
  •  
6.
  • Hagger, Martin S., et al. (author)
  • A Multilab Preregistered Replication of the Ego-Depletion Effect
  • 2016
  • In: Perspectives on Psychological Science. - : Sage Publications. - 1745-6916 .- 1745-6924. ; 11:4, s. 546-573
  • Journal article (peer-reviewed)abstract
    • Good self-control has been linked to adaptive outcomes such as better health, cohesive personal relationships, success in the workplace and at school, and less susceptibility to crime and addictions. In contrast, self-control failure is linked to maladaptive outcomes. Understanding the mechanisms by which self-control predicts behavior may assist in promoting better regulation and outcomes. A popular approach to understanding self-control is the strength or resource depletion model. Self-control is conceptualized as a limited resource that becomes depleted after a period of exertion resulting in self-control failure. The model has typically been tested using a sequential-task experimental paradigm, in which people completing an initial self-control task have reduced self-control capacity and poorer performance on a subsequent task, a state known as ego depletion. Although a meta-analysis of ego-depletion experiments found a medium-sized effect, subsequent meta-analyses have questioned the size and existence of the effect and identified instances of possible bias. The analyses served as a catalyst for the current Registered Replication Report of the ego-depletion effect. Multiple laboratories (k = 23, total N = 2,141) conducted replications of a standardized ego-depletion protocol based on a sequential-task paradigm by Sripada et al. Meta-analysis of the studies revealed that the size of the ego-depletion effect was small with 95% confidence intervals (CIs) that encompassed zero (d = 0.04, 95% CI [-0.07, 0.15]. We discuss implications of the findings for the ego-depletion effect and the resource depletion model of self-control.
  •  
7.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-7 of 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view