SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Henriksson Kerstin)
 

Sökning: WFRF:(Henriksson Kerstin) > (1998-1999) > Metabolite levels i...

Metabolite levels in human skeletal muscle and adipose tissue studied with microdialysis at low perfusion flow.

Rosdahl, Hans (författare)
Gymnastik- och idrottshögskolan,Institutionen för idrotts- och hälsovetenskap
Hamrin, Kerstin (författare)
Karolinska Institutet,Gymnastik- och idrottshögskolan,Institutionen för idrotts- och hälsovetenskap
Ungerstedt, Urban (författare)
Karolinska Institutet
visa fler...
Henriksson, Jan (författare)
Karolinska Institutet,Gymnastik- och idrottshögskolan,Institutionen för idrotts- och hälsovetenskap
visa färre...
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: The American journal of physiology. - 0002-9513. ; 274:5 Pt 1, s. E936-45
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To identify a perfusion flow at which the interstitial fluid completely equilibrates with the microdialysis perfusion fluid, a protocol with successively lower perfusion flows was used. A colloid was included in the perfusion fluid to make sampling possible at the lowest perfusion flows. At 0.16 microliter/min, the measured metabolites had reached a complete equilibration in both tissues, and the measured concentrations of glucose, glycerol, and urea were in good agreement with expected tissue-specific levels. The glucose concentration in adipose tissue (4.98 +/- 0.14 mM) was equal to that of plasma (5.07 +/- 0.07 mM), whereas the concentration in muscle (4.41 +/- 0.11 mM) was lower than in plasma and adipose tissue (P < 0.001). The concentration of lactate was higher (P < 0.001) in muscle (2.39 +/- 0.22 mM) than in adipose tissue (1.30 +/- 0.12 mM), whereas the glycerol concentration in adipose tissue (233 +/- 19.7 microM) was higher (P < 0.001) than in muscle (40.8 +/- 3.0 microM) and in plasma (68.7 +/- 3.97 microM). The concentration of urea was equal in the two tissues. Overall, the study indicates that microdialysis at a low perfusion flow may be a tool to continuously monitor tissue interstitial concentrations.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy