  • Andelin, M., et al. (författare)
  • Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.
  • 2016
  • Ingår i: Journal of Diabetes Science and Technology. - : Diabetes Technology Society. - 1932-2968. ; 10:4, s. 876-884
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Using the standard venous reference for the evaluation of continuous glucose monitoring (CGM) systems could possibly negatively affect measured CGM accuracy since CGM are generally calibrated with capillary glucose and venous and capillary glucose concentrations differ. We therefore aimed to quantify the effect of using capillary versus venous glucose reference samples on estimated accuracy in capillary calibrated CGM.less thanbr /greater thanMethods: We evaluated 41 individuals with type 1 diabetes mellitus (T1DM) using the Dexcom G4 CGM system over 6 days. Patients calibrated their CGM devices with capillary glucose by means of the HemoCue system. During 2 visits, capillary and venous samples were simultaneously measured by HemoCue and compared to concomitantly obtained CGM readings. The mean absolute relative difference (MARD) was calculated using capillary and venous reference samples.less thanbr /greater thanResults: Venous glucose values were 0.83 mmol/L (15.0 mg/dl) lower than capillary values over all glycemic ranges, P less than .0001. Below 4 mmol/l (72 mg/dl), the difference was 1.25 mmol/l (22.5 mg/dl), P = .0001, at 4-10 mmol/l (72-180 mg/dl), 0.67 mmol/l (12.0 mg/dl), P less than .0001 and above 10 mmol/l (180 mg/dl), 0.95 mmol/l (17.1 mg/dl), P less than .0001. MARD was 11.7% using capillary values as reference compared to 13.7% using venous samples, P = .037. Below 4 mmol/l (72 mg/dl) MARD was 16.6% and 31.8%, P = .048, at 4-10 mmol/l (72-180 mg/dl) 12.1% and 12.6%, P = .32, above 10 mmol/l (180 mg/dl) 8.7% and 9.2%, P = .82.less thanbr /greater thanConclusion: Using capillary glucose concentrations as reference to evaluate the accuracy of CGM calibrated with capillary samples is associated with a lower MARD than using venous glucose as the reference. Capillary glucose concentrations were significantly higher than venous in all glycemic ranges.less thanbr /greater than (© 2016 Diabetes Technology Society.)
  •  
7.
  • Lutman, A. A., et al. (författare)
  • Polarization control in an X-ray free-electron laser
  • 2016
  • Ingår i: Nature Photonics. - : Springer Science and Business Media LLC. - 1749-4885 .- 1749-4893. ; 10:7, s. 468-472
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray free-electron lasers are unique sources of high-brightness coherent radiation. However, existing devices supply only linearly polarized light, precluding studies of chiral dynamics. A device called the Delta undulator has been installed at the Linac Coherent Light Source (LCLS) to provide tunable polarization. With a reverse tapered planar undulator line to pre-microbunch the beam and the novel technique of beam diverting, hundreds of microjoules of circularly polarized X-ray pulses are produced at 500-1,200 eV. These X-ray pulses are tens of femtoseconds long, have a degree of circular polarization of 0.98(+0.02)(-0.04) at 707 eV and may be scanned in energy. We also present a new two-colour X-ray pump-X-ray probe operating mode for the LCLS. Energy differences of Delta E/E = 2.4% are supported, and the second pulse can be adjusted to any elliptical polarization. In this mode, the pointing, timing, intensity and wavelength of the two pulses can be modified.
  •  
8.
  •  
9.
  • Pierot, L, et al. (författare)
  • Standards of Practice in Acute Ischemic Stroke Intervention International Recommendations
  • 2019
  • Ingår i: The Canadian journal of neurological sciences. Le journal canadien des sciences neurologiques. - : Cambridge University Press (CUP). - 0317-1671 .- 2057-0155. ; 46:3, s. 269-274
  • Tidskriftsartikel (refereegranskat)abstract
    • After five positive randomized controlled trials showed benefit of mechanical thrombectomy in the management of acute ischemic stroke with emergent large-vessel occlusion, a multi-society meeting was organized during the 17th Congress of the World Federation of Interventional and Therapeutic Neuroradiology in October 2017 in Budapest, Hungary. This multi-society meeting was dedicated to establish standards of practice in acute ischemic stroke intervention aiming for a consensus on the minimum requirements for centers providing such treatment. In an ideal situation, all patients would be treated at a center offering a full spectrum of neuroendovascular care (a level 1 center). However, for geographical reasons, some patients are unable to reach such a center in a reasonable period of time. With this in mind, the group paid special attention to define recommendations on the prerequisites of organizing stroke centers providing medical thrombectomy for acute ischemic stroke, but not for other neurovascular diseases (level 2 centers). Finally, some centers will have a stroke unit and offer intravenous thrombolysis, but not any endovascular stroke therapy (level 3 centers). Together, these level 1, 2, and 3 centers form a complete stroke system of care. The multi-society group provides recommendations and a framework for the development of medical thrombectomy services worldwide.
  •  