SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ivanova Darya) srt2:(2013)"

Sökning: WFRF:(Ivanova Darya) > (2013)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abel, I, et al. (författare)
  • Overview of the JET results with the ITER-like wall
  • 2013
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 53:10, s. 104002-
  • Tidskriftsartikel (refereegranskat)abstract
    • Following the completion in May 2011 of the shutdown for the installation of the beryllium wall and the tungsten divertor, the first set of JET campaigns have addressed the investigation of the retention properties and the development of operational scenarios with the new plasma-facing materials. The large reduction in the carbon content (more than a factor ten) led to a much lower Z(eff) (1.2-1.4) during L- and H-mode plasmas, and radiation during the burn-through phase of the plasma initiation with the consequence that breakdown failures are almost absent. Gas balance experiments have shown that the fuel retention rate with the new wall is substantially reduced with respect to the C wall. The re-establishment of the baseline H-mode and hybrid scenarios compatible with the new wall has required an optimization of the control of metallic impurity sources and heat loads. Stable type-I ELMy H-mode regimes with H-98,H-y2 close to 1 and beta(N) similar to 1.6 have been achieved using gas injection. ELM frequency is a key factor for the control of the metallic impurity accumulation. Pedestal temperatures tend to be lower with the new wall, leading to reduced confinement, but nitrogen seeding restores high pedestal temperatures and confinement. Compared with the carbon wall, major disruptions with the new wall show a lower radiated power and a slower current quench. The higher heat loads on Be wall plasma-facing components due to lower radiation made the routine use of massive gas injection for disruption mitigation essential.
  •  
2.
  • Brezinsek, S., et al. (författare)
  • Residual carbon content in the initial ITER-Like Wall experiments at JET
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 438:Suppl., s. S303-S308
  • Tidskriftsartikel (refereegranskat)abstract
    • The residual carbon content and carbon edge flux in JET have been assessed by three independent diagnostic techniques after start of plasma operation with the ITER-Like Wall (ILW) with beryllium first wall and tungsten divertor: (i) in-situ measurements with optical spectroscopy on low ionisation stages of carbon, (ii) charge-exchange recombination spectroscopy, and (iii) residual gas composition analysis in dedicated global gas balance experiments. Direct comparison experiments in L-mode discharges were carried out between references from the previously installed material configuration with plasma-facing components made of carbon-fibre composite (JET-CFC) and the JET-ILW. The temporal evolution of the C divertor flux since installation of the ILW has been studied in the ohmic phase of dedicated monitoring discharges which have been executed regularly throughout the experimental exploitation so far (60000 plasma seconds). The C flux behaviour in the divertor can be divided in three phases: initial fast drop, moderate reduction phase, and a long lasting phase with almost constant C flux. The Be flux in both divertor legs mirrors the behaviour of C. All experiments and diagnostic techniques demonstrate a strong reduction in C fluxes and C content of more than one order of magnitude with respect to JET-CFC which is in line with the reduction in long-term fuel retention due to co-deposition. There is no evidence of an increase in residual carbon in time, thus no indication that a damage of the thin tungsten coatings on CFC substrate in the divertor occurred.
  •  
3.
  • Coenen, J. W., et al. (författare)
  • Long-term evolution of the impurity composition and impurity events with the ITER-like wall at JET
  • 2013
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 53:7, s. 073043-
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper covers aspects of long-term evolution of intrinsic impurities in the JET tokamak with respect to the newly installed ITER-like wall (ILW). At first the changes related to the change over from the JET-C to the JET-ILW with beryllium (Be) as the main wall material and tungsten (W) in the divertor are discussed. The evolution of impurity fluxes in the newly installed W divertor with respect to studying material migration is described. In addition, a statistical analysis of transient impurity events causing significant plasma contamination and radiation losses is shown. The main findings comprise a drop in carbon content (x20) (see also Brezinsek et al (2013 J. Nucl. Mater. 438 S303)), low oxygen content (x10) due to the Be first wall (Douai et al 2013 J. Nucl. Mater. 438 S1172-6) as well as the evolution of the material mix in the divertor. Initially, a short period of repetitive ohmic plasmas was carried out to study material migration (Krieger et al 2013 J. Nucl. Mater. 438 S262). After the initial 1600 plasma seconds the material surface composition is, however, still evolving. With operational time, the levels of recycled C are increasing slightly by 20% while the Be levels in the deposition-dominated inner divertor are dropping, hinting at changes in the surface layer material mix made of Be, C and W. A steady number of transient impurity events, consisting of W and constituents of inconel, is observed despite the increase in variation in machine operation and changes in magnetic configuration as well as the auxiliary power increase.
  •  
4.
  • Ivanova, Darya, et al. (författare)
  • Assessment of Cleaning Methods for First Mirrors Tested in JET for ITER
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier. - 0022-3115 .- 1873-4820. ; 438:Suppl., s. S1241-S1244
  • Tidskriftsartikel (refereegranskat)abstract
    • Two cleaning techniques were used for removal of co-deposits from the tested first mirrors exposed in JET: (a) ultrasonic bath; (b) a broad range of polishing conditions from manual buffing to machine polishing with the diamond grain size of up to 3 lm. Reflectivity measurements were performed after each step in the cleaning procedure. Surfaces were also examined with electron microscopy and ion beam analysis methods. Ultrasonic cleaning leads to partial recovery of reflectivity due to enhanced detachment of deposits. Typically 30-50% of the original reflectivity was recovered in the visible light and 50-90% in the infrared region. One mirror was cleaned completely. Polishing with diamond paste may lead to successful removal of deposits but the damage to the surface in case of the large diamond grains was observed. Recovery of up to 100% of the initial reflectivity was achieved for some mirrors.
  •  
5.
  • Krieger, K., et al. (författare)
  • Beryllium migration and evolution of first wall surface composition in the JET ILW configuration
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 438:Suppl., s. S262-S266
  • Tidskriftsartikel (refereegranskat)abstract
    • Material migration and the resulting evolution of plasma facing surfaces were studied at the beginning of the JET ILW campaign using the singular opportunity of well-defined initial conditions with virgin Be and W wall components. In a sequence of identical Ohmically heated discharges the evolution of wall material sources as well as that of residual impurity sources were studied by spectroscopic detection of suitable emission lines of corresponding neutral atom and singly charged ion species in the visible spectral range. The evolution of divertor surface composition resulting from wall material migration occurred at a similar time scale as previously observed in Be migration experiments in the JET carbon wall configuration. In contrast to these experiments with initial Be evaporation on the carbon main chamber wall, the JET ILW migration experiment is characterised by a continuous Be wall source because the main chamber wall now consists of bulk Be components. The experiment further reveals unexpectedly high Be deposition at W divertor surfaces already during preceding limiter discharges for system commissioning, which has implications for predictive modelling of the expected fuel retention in ITER.
  •  
6.
  • Rubel, Marek, et al. (författare)
  • Tungsten migration studies by controlled injection of volatile compounds
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 438, s. S170-S174
  • Tidskriftsartikel (refereegranskat)abstract
    • Volatile tungsten hexa-fluoride was locally injected into the TEXTOR tokamak as a marker for material migration studies. The injection was accompanied by puffing N-15 rare isotope as a nitrogen tracer in discharges with edge cooling by impurity seeding. The objective was to assess material balance by qualitative and quantitative determination of a global and local deposition pattern, material mixing effects and fluorine residence in plasma-facing components. Spectroscopy and ex situ ion beam analysis techniques were used. Tungsten was detected on all types of limiter tiles and short-term probes retrieved from the vessel. Over 80% of the injected W was identified. The largest tungsten concentration, 1 x 10(18) cm(-2), was in the vicinity of the gas inlet. Co-deposits contained tungsten and a mix of light isotopes: H, D, He-4, B-10, B-11, C-12, C-13, N-14, N-15, O-16 and small quantities of F-19 thus showing that both He and nitrogen are trapped following wall conditioning (He glow) and edge cooling.
  •  
7.
  • Wauters, T., et al. (författare)
  • Self-consistent application of ion cyclotron wall conditioning for co-deposited layer removal and recovery of tokamak operation on TEXTOR
  • 2013
  • Ingår i: Nuclear Fusion. - : Institute of Physics (IOP). - 0029-5515 .- 1741-4326. ; 53:12, s. 123001-
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a demonstration experiment of ion cyclotron wall conditioning (ICWC) on TEXTOR covering all ITER wall conditioning aims and discusses the implications for ITER. O-2/He-ICWC applied to erode carbon co-deposits removed 6.6x10(21) C-atoms (39 pulses, 158 s cumulated discharge time). Large oxygen retention (71% of injected oxygen) prevented subsequent ohmic discharge initiation. Plasma operation was recovered by a 1h47 multi-pulse D-2-ICWC procedure including pumping time between pulses with duty cycle of 2 s/20 s, cleaning the vessel from oxygen impurities, followed by a 23 min He-ICWC procedure (2 s/20 s), applied to desaturate the deuterium-loaded walls. A stable ohmic discharge was established on the first attempt right after the recovery procedure. The discharges showed improved density control and only slightly increased oxygen characteristic radiation levels (1-1.5 times). After the recovery procedure 36% of the injected O-atoms remained retained in the vessel, derived from mass spectrometry measurements. This amount is in the estimated range for storage in remote areas obtained from surface analysis of locally exposed samples. The removed amount of oxygen by D-2 and He-ICWC obtained from mass spectrometry corresponds to the retention in plasma-wetted areas estimated by surface analysis. It is concluded that most of the removed oxygen stems from plasma-wetted areas while shadowed areas, e. g. behind poloidal limiters, may feature net retention of the discharge gas. On ITER, designed with a shaped first wall, the ICWC plasma-wetted area will approach the total surface area, reducing consequently the retention in remote areas. A tentative extrapolation of the carbon removal on TEXTOR to tritium removal from co-deposits on ITER in the 39 x 4 s O-2/He-ICWC discharges, including pumping time between the RF pulses, corresponds on ITER to a tritium removal in the order of the estimated retention per 400 s DT-burn (140-500 mgT (Shimada and Pitts 2011 J. Nucl. Mater. 415 S1013-6)).
  •  
8.
  • Widdowson, A., et al. (författare)
  • Comparison of JET main chamber erosion with dust collected in the divertor
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 436:Suppl., s. 827-832
  • Tidskriftsartikel (refereegranskat)abstract
    • A complete global balance for carbon in JET requires knowledge of the net erosion in the main chamber, net deposition in the divertor and the amount of dust and flakes collecting in the divertor region. This paper describes a number of measurements on aspects of this global picture. Profiler measurements and cross section microscopy on tiles that were removed in the 2009 JET intervention are used to evaluate the net erosion in the main chamber and net deposition in the divertor. In addition the mass of dust and flakes collected from the JET divertor during the same intervention is also reported and included as part of the balance. Spectroscopic measurements of carbon erosion from the main chamber are presented and compared with the erosion measurements for the main chamber.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy