SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Jacobsson Lars 1947) srt2:(1990-1994)"

Sökning: WFRF:(Jacobsson Lars 1947) > (1990-1994)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Naredi, Peter, 1955, et al. (författare)
  • The influence of hepatic artery ligation and of vasopressin on liver tumour blood flow in rats.
  • 1992
  • Ingår i: Journal of surgical oncology. - : Wiley. - 0022-4790 .- 1096-9098. ; 50:2, s. 70-6
  • Tidskriftsartikel (refereegranskat)abstract
    • The blood flow in an experimental adenocarcinoma in the rat liver was determined with the 133Xe-washout technique before and after hepatic artery ligation (HAL). There was an initial reduction of the washout of 50%. This was further reduced after 1 day by 50%, which was maintained for 7 days. Seven days after HAL or sham procedures the 133Xe-washout was of similar magnitude in the liver tumours, although after the sham procedure the tumours were larger (3.4 g vs. 1.5 g). The estimated tumour blood flow was then approximately 0.04 ml x min-1 x g-1. The influence on normal liver parenchyma of HAL was a reduction at 30 minutes, which was maintained for 7 days. Postacton--a synthetic vasopressin--did not influence the 133Xe-washout in normal liver parenchyma in non-tumour, as well as in tumour-bearing animals. There was no influence of Postacton on the 133Xe-washout in the liver tumours. Thirty minutes after HAL Postacton gave a reduction of blood flow in normal liver parenchyma of tumour-bearing animals, which is thus only from the portal vein. In tumours Postacton did not significantly reduce the tumour blood flow immediately after HAL.
  •  
2.
  • Naredi, Peter, 1955, et al. (författare)
  • Evaluation of blood flow measurements with microspheres and rubidium--an experimental study in rats.
  • 1990
  • Ingår i: International journal of microcirculation, clinical and experimental / sponsored by the European Society for Microcirculation. - 0167-6865. ; 9:4, s. 423-37
  • Tidskriftsartikel (refereegranskat)abstract
    • The microsphere method has been widely used for blood flow measurements in normal and tumour tissues. The microsphere method was evaluated for repeated measurements of cardiac output and regional blood flow in anesthetised rats and in anesthetised rats given noradrenalin and thereby having altered haemodynamics with special emphasis on liver blood flow. Comparing the microsphere method with the soluble indicator method (86Rubidium) gave equal cardiac output values. The liver blood flow was lower and the spleen blood flow was higher with the microsphere method. Two microsphere injections at 10 min intervals were performed on anesthetised rats. In one group 817 +/- 10(3) microspheres were injected each time, in a second group 436 +/- 10(3) and in a third noradrenalin was added and then 430 +/- 10(3) microspheres injected twice. There was good reproducibility for cardiac output and for most organ and tissue blood flows between first and second microsphere injection. No influence on arterial liver blood flow was seen. A blood pressure fall and a decreased heart rate was registered after the first injection in the group given 817 x 10(3) spheres. There was also a blood pressure fall in the group given noradrenalin after the first microsphere injection. The microsphere method with two injections of 436 x 10(3) microspheres seems adequate to use in arterial blood flow studies of the liver and simultaneous cardiac output measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy