1.
  • Jakobsson, P, et al. (författare)
  • Wash-in and wash-out of sevoflurane in a test-lung model: A comparison between Aisys and FLOW-i
  • 2017
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 6, s. 389-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background:Modern anaesthesia workstations are reassuringly tight and are equipped with effective gas monitoring, thus providing good opportunities for low/minimal flow anaesthesia. A prerequisite for effective low flow anaesthesia is the possibility to rapidly increase and decrease gas concentrations in the circle system, thereby controlling the depth of anaesthesia. Methods:We studied the wash-in and wash-out of sevoflurane in the circle system with fixed fresh gas flow and vaporizer setting. We compared two modern anaesthesia work stations, the Aisys (GE, Madison, WI, USA) and FLOW-i (Maquet, Solna, Sweden) in a test lung model. Results: We found fresh-gas flow to have, as expected, a major influence on wash-in, as well as wash-out of sevoflurane. The wash-in time to reach a stable circle 1 MAC (2.1%) decreased from an average of 547 ± 83 seconds with a constant fresh gas flow of 300 ml/min and vaporizer setting of 8%, to a mean of 38 ± 6 seconds at a fresh gas flow of 4 L/min. There were only minor differences between the two works-stations tested; the Aisys was slightly faster at both 300 and 4 L/min flow. Time to further increase circle end-tidal concentration from 1-1.5 MAC showed likewise significant associations to fresh gas and decreased from 330 ± 24 seconds at 300 ml/min. to less than a minute at constant 4 L/min (17 ± 11 seconds), without anaesthetic machine difference. Wash-out was also fresh gas flow dependent and plateaued at 7.5 L/min. Conclusions: Circle system wash-in and wash-out show clear fresh gas dependency and varies somewhat between the Aisys and Flow-i. The circle saturation, reaching 1 MAC end-tidal or increasing from 1-1.5 MAC can be achieved with both work-stations within 1.5 minutes at a constant fresh gas flow of 2 and 4 L/min. Wash-out plateaued at 7.5 L/min.
  •  
2.
  •  
3.
  • Galmén, K, et al. (författare)
  • High Frequency Jet Ventilation during stereotactic ablation of liver tumours: an observational study on blood gas analysis as a measure of lung function during general anaesthesia
  • 2019
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 8, s. 386-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Stereotactic ablation of tumours in solid organs is a promising curative procedure in clinical oncology. The technique demands minimal target organ movements to optimise tumour destruction and prevent injury to surrounding tissues. High frequency jet ventilation (HFJV) is a novel option during these procedures, reducing the respiratory-associated movements of the liver. The effects of HFJV via endotracheal catheter on gas exchange during liver tumour ablation is not well studied. Methods: The aim of this explorative study was to assess lung function and the effects on blood gas and lactate during HFJV in patients undergoing stereotactic liver ablation. Blood gases were analysed in 25 patients scheduled for stereotactic liver ablation under general anaesthesia pre-induction, every 15 minutes during HFJV and following extubation in the recovery room. The HFJV was set at fixed settings. Results: None of the patients developed hypoxia or signs of increased lactate production but a great variation in PaO2/FiO2 ratio was found; from 13.1 to 71.3. An increase in mean PaCO2 was observed, from a baseline of 5.0 to a peak of 7.1 at 30 minutes (p <0.001) and a decrease was found in median pH, from a baseline of 7.44 to 7.31 at 15 minutes (p=0.03). We could not see any clear association between a decrease in PaO2/FiO2 ratio and PaCO2 elevation. Conclusions: HFJV during general anaesthesia in patients undergoing stereotactic liver ablation is feasible and it did not cause hypoxemia or signs of increased lactate production. A reversible mild to moderate impairment of gas exchange was found during HFJV.
  •  
4.
  •  
5.
  • Galmén, K, et al. (författare)
  • The use of high-frequency ventilation during general anaesthesia: an update
  • 2017
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 6, s. 756-
  • Tidskriftsartikel (refereegranskat)abstract
    • Various forms of high-frequency ventilation (HFV) have been described. HFV is broadly defined as artificial ventilation of the lungs with sub-deadspace tidal volumes delivered using supra-physiological frequencies. HFV has been used in anaesthesia and intensive care for special procedures and conditions since the 1960s. Clinical interest in the use and the technical evolution of HFV has developed over time. There is a renewed interest in HFV for avoiding parenchymal movement during stereotactic tumour ablation. The present paper aims to give an overview of the fundamental physiology, technical aspects, and clinical challenges of HFV in ablation procedures during general anaesthesia, where HFV is used to minimise the movements of the ablation target.
  •  
6.
  •  
7.
  • Gremillet, C, et al. (författare)
  • Acute hip fracture surgery anaesthetic technique and 30-day mortality in Sweden 2016 and 2017: A retrospective register study
  • 2018
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 7, s. 1009-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Hip fractures affect 1.6 million patients yearly worldwide, often elderly with complex comorbidity. Mortality following surgery for acute hip fracture is high and multifactorial; high age, comorbidities and complication/deterioration in health following surgery. Whether the anaesthesia technique affects the 30-day mortality rate has been studied widely without reaching a consensus. The primary aim of this study was to determine anaesthetic techniques used in Sweden and their impact on the 30-day mortality rate in elderly undergoing acute hip fracture surgery. Other aims were to study the impact of age, gender, ASA class, fracture type and delay in surgery on the 30-day mortality rate. Methods: Data from 13,649 patients ≥50 years old who had undergone acute hip fracture surgery and been reported to Swedish perioperative register (SPOR) between 2016 and 2017 were analysed.     Results: The most commonly used anaesthetic technique was neuraxial anaesthesia (NA; 11,257, 82%), followed by general anaesthesia (GA; 2,190, 16%) and combined general and neuraxial anaesthesia (CA; 202, 1.5%) out of the 13,649 studied. The 30-day mortality rate was 7.7% for the entire cohort; GA 7.8%, NA 7.7% and CA 7.4%. Mortality was higher in elderly patients, those with a high ASA class, pertrochanteric fracture and males.     Conclusions: The present study showed that NA is by far the most common anaesthetic technique for acute hip fracture surgery in Sweden. However, the anaesthetic technique used during this type of surgery had no impact on the 30-day mortality rate in patients. Increasing age, ASA class and male gender increased the 30-day mortality.
  •  
8.
  • Hein, A, et al. (författare)
  • Neuraxial opioids as analgesia in labour, caesarean section and hysterectomy: A questionnaire survey in Sweden
  • 2017
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 6, s. 133-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Neuraxial opioids improve labour analgesia and analgesia after caesarean section (CS) and hysterectomy. Undesirable side effects and difficulties in arranging postoperative monitoring might influence the use of these opioids. The aim of the present survey was to assess the use of intrathecal and epidural morphine in gynaecology and obstetrics in Sweden. Methods: A questionnaire was sent to all anaesthetic obstetric units in Sweden concerning the use and postoperative monitoring of morphine, sufentanil and fentanyl in spinal/epidural anaesthesia. Results: A total of 32 of 47 (68%) units responded representing 83% of annual CS in Sweden. In CS spinal anaesthesia, 20/32 units use intrathecal morphine, the most common dose of which was 100 μg (17/21). Intrathecal fentanyl (10-20 μg) was used by 21 units and sufentanil (2.5 -10 μg) by 9/32 of the responding units. In CS epidural anaesthesia, epidural fentanyl (50-100 μg) or sufentanil (5-25 μg) were commonly used (25/32), and 12/32 clinics used epidural morphine, the majority of units used a 2 mg dose. Intrathecal morphine for hysterectomy was used by 20/30 units, with 200 μg as the most common dose (9/32). Postoperative monitoring was organized in adherence to the National Guidelines; the patient is monitored postoperative care or an obstetrical ward over 2-6 hours and up-to 12 hours in an ordinary surgical ward. Risk of respiratory depression/difficult to monitor was a reason for not using intrathecal opioids. Conclusions: Neuraxial morphine is used widely in Sweden in CS and hysterectomy, but is still restricted in some units because of the concern for respiratory depression and difficulties in monitoring.
  •  
9.
  • Hein, A, et al. (författare)
  • Portable respiratory polygraphy monitoring of obese mothers the first night after caesarean section with bupivacaine/morphine/fentanyl spinal anaesthesia
  • 2017
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 6, s. 2062-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background:Obesity, abdominal surgery, and intrathecal opioids are all factors associated with a risk for respiratory compromise. The aim of this explorative trial was to study the apnoea/hypopnea index 1st postoperative night in obese mothers having had caesarean section (CS) in spinal anaesthesia with a combination of bupivacaine/morphine and fentanyl.Methods:Consecutive obese (BMI >30 kg/m 2) mothers, ≥18 years, scheduled for CS with bupivacaine/morphine/fentanyl spinal anaesthesia were monitored with a portable polygraphy device Embletta /NOX on 1stpostoperative night. The apnoea/hypopnea index (AHI) was identified by clinical algorithm and assessed in accordance to general guidelines; number of apnoea/hypopnea episodes per hour: <5 “normal”, ≥5 and <15mild sleep apnoea, ≥15 and <30moderate sleep apnoea,≥ 30severe sleep apnoea. Oxygen desaturation events were in similar manner calculated per hour as oxygen desaturation index (ODI).Results:Forty mothers were invited to participate: 27 consented, 23 were included, but polysomnography registration failed in 3. Among the 20 mothers studied: 11 had an AHI <5 (normal), 7 mothers had AHI ≥5 but <15 (mild OSAS) and 2 mothers had AHI ≥15 (moderate OSA), none had an AHI ≥ 30. The ODI was on average 4.4, and eight patients had an ODI >5. Mothers with a high AHI (15.3 and 18.2) did not show high ODI. Mean saturation was 94% (91-96%), and four mothers had mean SpO290-94%, none had a mean SpO2 <90%.Conclusion:Respiratory polygraphy 1stnight after caesarean section in spinal anaesthesia with morphine in moderately obese mothers showed AHIs that in sleep medicine terms are considered normal, mild and moderate. Obstructive events and episodes of desaturation were commonly not synchronised. Further studies looking at preoperative screening for sleep apnoea in obese mothers are warranted but early postop respiratory polygraphy recording is cumbersome and provided sparse important information.
  •  
10.
  • Hein, A, et al. (författare)
  • The decision to delivery interval in emergency caesarean sections: Impact of anaesthetic technique and work shift
  • 2017
  • Ingår i: F1000Research. - : F1000 Research Ltd. - 2046-1402. ; 6, s. 1977-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: One important task of the emergency anaesthesia service is to provide rapid, safe and effective anaesthesia for emergency caesarean sections (ECS). A Decision to Delivery Interval (DDI) <30 minutes for ECS is a quality indicator for this service. The aim of this study was to assess the DDI and the impact of chosen anaesthetic technique (general anaesthesia (GA), spinal anaesthesia (SPA) with opioid supplementation, or “top-up” of labour epidural analgesia (tEDA) with local anaesthesia and fentanyl mixture) and work shift for ECS at Danderyds Hospital, Sweden. Methods: A retrospective chart review of ECS at Danderyds Hospital was performed between January and October 2016. Time between decision for CS, start of anaesthesia, time for incision and delivery, type of anaesthetic technique, and time of day, working hours or on call and day of week, Monday – Friday, and weekend was compiled and analysed. Time events are presented as mean ± standard deviation. Non-parametric tests were used. Results: In total, 135 ECS were analysed: 92% of the cases were delivered within 30 minutes and mean DDI for all cases was 17.3±8.1 minutes. GA shortened the DDI by 10 and 13 minutes compared to SPA and tEDA (p<0.0005). DDI for SPA and tEDA did not differ. There was no difference in DDI regarding time of day or weekday. Apgar <7 at 5’ was more commonly seen in ECS having GA (11 out of 64) compared to SPA (2/30) and tEDA (1/41) (p<0.05). Conclusion: GA shortens the DDI for ECS, but the use of SPA as well as tEDA with opioid supplementation maintains a short DDI and should be considered when time allows. Top-up epidural did not prolong the DDI compared to SPA. The day of week or time of ECS had no influence on the anaesthesia service as measured by the DDI.
  •  