SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Jasir Aftab)
 

Search: WFRF:(Jasir Aftab) > (2002) > Are current rapid d...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Are current rapid detection tests for Group A Streptococci sensitive enough? Evaluation of 2 commercial kits

Nerbrand, Christina (author)
Lund University,Lunds universitet,Allmänmedicin och samhällsmedicin,Forskargrupper vid Lunds universitet,Family Medicine and Community Medicine,Lund University Research Groups
Jasir, Aftab (author)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
Schalén, Claës (author)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
 (creator_code:org_t)
2009-07-08
2002
English.
In: Scandinavian Journal of Infectious Diseases. - : Informa UK Limited. - 1651-1980 .- 0036-5548. ; 34:11, s. 797-799
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A new, 1-step, enzyme-linked immunoassay kit for detection of Group A Streptococci (GAS) in throat samples (QuickVue In-Line One-Step Strep A Test; Quidel Corporation, San Diego, CA) was evaluated for use in a study comprising 536 patients in 8 primary healthcare centres. Compared to conventional culture at the clinical microbiology laboratory, the sensitivity achieved was 73.9% and the specificity 86.8%; these figures were not affected to any major extent by broth enrichment of samples before culturing or following PCR testing of the cysteine proteinase gene for independent diagnosis of GAS. It was also found that most samples containing low numbers of GAS were missed by the rapid test. We therefore evaluated the kit in use in our area (TestPack Plus Strep A Test; Abbott Laboratories, Chicago, IL) in a separate study of 615 patients. Somewhat increased sensitivity (82.8%) and specificity (96.1%) were obtained. As current antigen tests depend on subjective judgement of test outcome, improvements in test design or provision of more detailed instructions may be desirable in order to achieve optimal results.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Infektionsmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Infectious Medicine (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Nerbrand, Christ ...
Jasir, Aftab
Schalén, Claës
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Infectious Medic ...
Articles in the publication
Scandinavian Jou ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view