Sökning: WFRF:(Johansen Jens Brock)
> (2020) >
Development of the ...
Development of the Implantable Cardioverter Defibrillator Body Image Concerns Questionnaire
-
- Frydensberg, Vivi Skibdal (författare)
- Univ Southern Denmark, Denmark; Odense Univ Hosp, Denmark; Odense Patient Data Explorat Network OPEN, Denmark
-
- Strömberg, Anna, 1967- (författare)
- Linköpings universitet,Avdelningen för omvårdnad och reproduktiv hälsa,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken US
-
- Johansen, Jens Brock (författare)
- Odense Univ Hosp, Denmark
-
visa fler...
-
- Pedersen, Susanne S. (författare)
- Univ Southern Denmark, Denmark; Odense Univ Hosp, Denmark; Univ Southern Denmark, Denmark
-
visa färre...
-
(creator_code:org_t)
- LIPPINCOTT WILLIAMS & WILKINS, 2020
- 2020
- Engelska.
-
Ingår i: Journal of Cardiovascular Nursing. - : LIPPINCOTT WILLIAMS & WILKINS. - 0889-4655 .- 1550-5049. ; 35:2, s. 165-183
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background The implantable cardioverter defibrillator (ICD) is the first-line treatment for the prevention of sudden cardiac death. Although most ICD recipients adapt well to living with the device, some struggle with ICD-related body image concerns (BICs). Because of lack of standardized questionnaires to assess BICs, we do not know the prevalence. Objective The aim of this study was to develop a questionnaire that assesses self-reported ICD-related BICs. Methods Using a sequential, qualitative multimethod approach, we developed the ICD-BIC questionnaire (ICD-BICQ) based on (1) themes from a scoping review on BICs in ICD recipients, (2) cognitive interviews with ICD recipients to evaluate the validity of items and to ascertain whether items were missing, and (3) input from healthcare professionals. A conceptual framework was created containing 4 general dimensions: (1) assessment, (2) behavior, (3) body perception, and (4) emotions. Results Implantable cardioverter defibrillator recipients (n = 8, 2 women and 6 men; age, 40-78 years), 2 specialists in questionnaire development, and healthcare professionals specialized in ICD treatment evaluated the questionnaire. After no new items or new dimensions emerged from the cognitive interviews, the final version 7 of the ICD-BICQ consisted of 39 items tapping into (1) assessment (n = 2), (2) behavior (n = 13), (3) body perception (n = 16), and emotions (n = 8). Items were assessed on a 5-point Likert-type scale. Conclusion Using patient and healthcare professionals involvement, we developed the 39-item ICD-BICQ to measure the prevalence of BICs in ICD recipients. The factor structure, construct validity, psychometric properties, and a clinically relevant cutoff for the ICD-BICQ will be evaluated in a quantitative study of ICD recipients.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Omvårdnad (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Nursing (hsv//eng)
Nyckelord
- body image; defibrillators; implantable; patient-reported outcomes; questionnaire design
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas