SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Johansson U.) srt2:(1980-1989)"

Sökning: WFRF:(Johansson U.) > (1980-1989)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Malmqvist, K. G., et al. (författare)
  • PIXE and proton microprobe advances at the Lund Institute of Technology
  • 1989
  • Ingår i: Nuclear Inst. and Methods in Physics Research, B. - 0168-583X. ; 40-41:PART 1, s. 685-689
  • Tidskriftsartikel (refereegranskat)abstract
    • A review of recent advances in high-energy ion beam analysis at the Lund Institute of Technology is presented. A nonvacuum specimen chamber allows chemical speciation using a combination of ion beam analysis and controlled heating. The development of a new versatile scanning proton microbeam based on a new dedicated accelerator, an achromatic triplet lens and an advanced specimen chamber is outlined together with the performance of a microVAX-II/VMEbus-based data acquisition system.
  •  
2.
  • Andersson-Engels, Stefan, et al. (författare)
  • Laser-induced fluorescence used in localizing atherosclerotic lesions
  • 1989
  • Ingår i: Lasers in Medical Science. - 0268-8921. ; 4:3, s. 171-181
  • Tidskriftsartikel (refereegranskat)abstract
    • We have investigated laser-induced fluorescence frompost mortem human arteries in order to find spectroscopic properties allowing discrimination between normal and atherosclerotic vessel wall. A pulsed nitrogen laser emitting light at a wavelength of 337.1 nm was used as an excitation source. The fluorescence spectrum from 370 to 700 nm was captured and analysed by an optical multichannel analyser. Dimensionless contrast functions were formed by using characteristic spectral features at 390, 415, 480, 580 and 600 nm. All samples were investigated in scans across a region where normal as well as diseased vessel wall appeared. The types of plaque were histopathologically divided into four groups, of which three could be singled out using one or more of our spectroscopic criteria. We also investigated the different layers of the normal and diseased vessel wall in order to determine the various contributions to the fluorescence signal. Furthermore, plasma emission spectra were recorded while ablating the normal as well as the diseased vessel wall with an excimer laser, emitting radiation at 308 nm, thus detecting the change in spectral characteristics during the ablation process down into deeper layers.
  •  
3.
  • Andersson-Engels, S., et al. (författare)
  • Tissue diagnostics using laser-induced fluorescence
  • 1989
  • Ingår i: Berichte der Bunsengesellschaft für Physikalische Chemie. - : Wiley. - 0005-9021. ; 93:3, s. 335-342
  • Tidskriftsartikel (refereegranskat)abstract
    • We have performed extensive investigations of laser-induced fluorescence in animal and human tissue aimed at instant tissue characterization. Autofluorescence, as well as specific fluorescence from HPD/DHE and other photosensitizers, has been utilized. The studies have been focused on the demarcation of malignant tumours and atheroscleortic plaques. A nitrogen laser or an excimer-pumped dye laser was used to induce fluorescence, which was analysed with an intensified optical multichannel system. A fibre-optic sensor system was developed for the clinical work. Multi-colour fluorescence imaging has also been demonstrated along a line and equipment for two-dimensional imaging is being constructed. Dimensionless spectroscopic functions, which are not affected by factors that are clinically uncontrollable have been employed for optimum tissue discrimination. The investigations have so far been performed in a time-integrated mode, but time-resolved studies are now being initiated to fully exploit the diagnostic power of tissue laser-induced fluorescence. In addition to a presentation of our own work a brief review of tissue fluorescence studies performed by other groups is also given.
  •  
4.
  • Ekberg, JO, et al. (författare)
  • Accurate experimental lifetimes of excited levels in sodiumlike sulfur, S VI
  • 1983
  • Ingår i: Physica Scripta. - : IOP Publishing. - 0031-8949 .- 1402-4896. ; 27:6, s. 425-425
  • Tidskriftsartikel (refereegranskat)abstract
    • The lifetimes of the terms 3p2P, 3d2D, 4s2S, 4p2P, 4d2D, 4f2F, 5g2G, 6g2G, 6h2H, 7h2H, 7i2I and 8k2K in sodiumlike sulfur, S VI, have been determined using the beam-foil excitation technique. Most of the decay curves were analyzed by means of the ANDC method which corrects for cascading in a very detailed way. Accurate results were thereby obtained which show that an excellent agreement exists between experimental and theoretical values. Some previously noted disagreements between the results of beam-foil experiments and theoretical investigations are explained as being due to less accurate analyses of the experimental data.
  •  
5.
  • Gillberg, Christopher, 1950, et al. (författare)
  • Auditory brainstem responses in childhood psychosis.
  • 1983
  • Ingår i: Journal of Autism and Developmental Disorders. - 0162-3257. ; 13:2, s. 181-195
  • Tidskriftsartikel (refereegranskat)abstract
    • Auditory brainstem responses were compared in 24 autistic children, 7 children with other childhood psychoses, and 31 normal children. One-third of the autistic children showed abnormal ABR indicative of brainstem dysfunction and correlating with muscular hypotonia and severe language impairment. The children with other psychoses and the normal children showed normal results.
  •  
6.
  •  
7.
  •  
8.
  • Roepstorff, P., et al. (författare)
  • Application of Plasma Desorption Mass Spectrometry to Molecular Weight Determination of Structural Protein from Insect Cuticle
  • 1986
  • Ingår i: Journal of Mass Spectrometry. - : Wiley. - 1076-5174 .- 1096-9888. ; 13:12, s. 689-691
  • Tidskriftsartikel (refereegranskat)abstract
    • During sequence determination of a structural protein from the cuticle of the migratory locust, Locusta migratoria, a discrepancy was found between the molecular weight calculated from the sequence data (15 323) and that estimated by SDS-gel electrophoresis (21 600). The protein contains several repeated sequences, and the discrepancy might indicate that part of the sequence was missing or that the protein contained a large prosthetic group. The molecular weight of the protein was determined by 127I-plasma desorption mass spectrometry to be 15 329±50 which confirms the sequence data and shows the molecular weight determination based on SDS-electrophoresis to be too high.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy