SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kalbfleisch Sebastian) srt2:(2022)"

Sökning: WFRF:(Kalbfleisch Sebastian) > (2022)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carbone, Dina, et al. (författare)
  • Design and performance of a dedicated coherent X-ray scanning diffraction instrument at beamline NanoMAX of MAX IV
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 29, s. 876-887
  • Tidskriftsartikel (refereegranskat)abstract
    • The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick-Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.
  •  
2.
  • Kahnt, Maik, et al. (författare)
  • Complete alignment of a KB-mirror system guided by ptychography
  • 2022
  • Ingår i: Optics Express. - 1094-4087. ; 30:23, s. 42308-42322
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate how the individual mirrors of a high-quality Kirkpatrick-Baez (KB) mirror system can be aligned to each other to create an optimally focused beam, through minimizing aberrations in the phase of the ptychographically reconstructed pupil function. Different sources of misalignment and the distinctive phase artifacts they create are presented via experimental results from the alignment of the KB mirrors at the NanoMAX diffraction endstation. The catalog of aberration artifacts can be used to easily identify which parameter requires further tuning in the alignment of any KB mirror system.
  •  
3.
  • Kalbfleisch, Sebastian, et al. (författare)
  • X-ray in-line holography and holotomography at the NanoMAX beamline
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - : International Union of Crystallography (IUCr). - 0909-0495 .- 1600-5775. ; 29, s. 224-229
  • Tidskriftsartikel (refereegranskat)abstract
    • Coherent X-ray imaging techniques, such as in-line holography, exploit the high brilliance provided by diffraction-limited storage rings to perform imaging sensitive to the electron density through contrast due to the phase shift, rather than conventional attenuation contrast. Thus, coherent X-ray imaging techniques enable high-sensitivity and low-dose imaging, especially for low-atomic-number (Z) chemical elements and materials with similar attenuation contrast. Here, the first implementation of in-line holography at the NanoMAX beamline is presented, which benefits from the exceptional focusing capabilities and the high brilliance provided by MAX IV, the first operational diffractionlimited storage ring up to approximately 300 eV. It is demonstrated that in-line holography at NanoMAX can provide 2D diffraction-limited images, where the achievable resolution is only limited by the 70 nm focal spot at 13 keV X-ray energy. Also, the 3D capabilities of this instrument are demonstrated by performing holotomography on a chalk sample at a mesoscale resolution of around 155 nm. It is foreseen that in-line holography will broaden the spectra of capabilities of MAX IV by providing fast 2D and 3D electron density images from mesoscale down to nanoscale resolution.
  •  
4.
  • Sala, Simone, et al. (författare)
  • Dose-efficient multimodal microscopy of human tissue at a hard X-ray nanoprobe beamline
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 29:3
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray fluorescence microscopy performed at nanofocusing synchrotron beamlines produces quantitative elemental distribution maps at unprecedented resolution (down to a few tens of nanometres), at the expense of relatively long measuring times and high absorbed doses. In this work, a method was implemented in which fast low-dose in-line holography was used to produce quantitative electron density maps at the mesoscale prior to nanoscale X-ray fluorescence acquisition. These maps ensure more efficient fluorescence scans and the reduction of the total absorbed dose, often relevant for radiation-sensitive (e.g. biological) samples. This multimodal microscopy approach was demonstrated on human sural nerve tissue. The two imaging modes provide complementary information at a comparable resolution, ultimately limited by the focal spot size. The experimental setup presented allows the user to swap between them in a flexible and reproducible fashion, as well as to easily adapt the scanning parameters during an experiment to fine-tune resolution and field of view.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy