SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kassapidou Maria)
 

Sökning: WFRF:(Kassapidou Maria) > (2022) > Cobalt-Chromium all...

Cobalt-Chromium alloys in fixed prosthodontics

Kassapidou, Maria (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
 (creator_code:org_t)
ISBN 9789180095952
Göteborgs universitet, 2022
Engelska.
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Gold and its alloys have been the dominant framework materials in metal-ceramic constructions when substantial loss of tooth substance or missing teeth needs to be replaced. However, base metal alloys, such as cobalt-chromium (Co-Cr), have been introduced due to increased gold price. Co-Cr alloys possess beneficial mechanical properties because the alloys can, even with small dimensions, resist high chewing forces and exhibit an acceptable bond to the surface porcelain layer. Yet, the biocompatibility of Co-Cr alloys has been questioned. The overall aim of the present thesis is to increase our knowledge about Co-Cr alloys that are used in fixed prosthodontics. Results from Study I, which was a survey directed to all dental laboratories in Sweden, demonstrated that more than thirty different Co-Cr alloys were reported to be used in fixed prosthodontics. Besides the various chemical composition among the reported alloys, they were also manufactured by four different techniques; cast, milled, laser melted and pre-sintered milled. Based on the results from Study I, five Co-Cr alloys manufactured by four techniques, together with commercially pure titanium (c.p. Ti) grade 4 and Ti6Al4V ELI, were further included in Studies II-IV. In vitro studies were conducted in order to evaluate ion release, cell viability and inflammatory response. The effect of material combinations was also investigated. The mechanical properties and material structure with regards to yield strength, elongation after fracture, hardness, elastic modulus, surface roughness and microstructure were evaluated. The effect of heat treatment was also investigated on the above-mentioned parameters. The total ion release from all materials was extremely low, yet highest for the cast Co-Cr alloys in acidic conditions. The combination of Co-Cr, Ti6Al4V ELI and c.p. Ti showed lower total ion release compared with the non-presence of c.p. Ti. All tested materials demonstrated non-cytotoxic effects, although the highest inflammatory response from cells exposed to the materials was observed for the cast and pre-sintered milled Co-Cr materials. Overall, the laser melted Co-Cr demonstrated the highest values in mechanical properties. Conclusion: In vitro biological aspects and mechanical properties are influenced by the choice of manufacturing technique, heat treatment and microstructure of the materials. In order to evaluate these findings, more clinical studies are needed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

prosthodontics
cobalt-chromium
manufacturing techniques

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kassapidou, Mari ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy