SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kertesz A.) srt2:(2005-2009)"

Sökning: WFRF:(Kertesz A.) > (2005-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aguer, P, et al. (författare)
  • Skin morphology and layer identification using different STIM geometries
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 231:1-4, s. 292-299
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of on-axis geometry in scanning transmission ion microscopy (STIM) has been widely used for thin biological sample structure identification. In this configuration, the lateral resolution is optimised so that micron or submicron beam spots are easily achieved even for classic microbeam lines. Off-axis STIM was more particularly employed for rapid imaging, and also (when associated to a scattering set-up) for normalising elemental contents obtained by other ion beam analysis techniques in organic thin samples. Due to the very small beam current required, on-axis STIM is a stand-alone technique. Off-axis STIM can be advantageous as it enables the simultaneous utilisation of PIXE and RBS techniques. In this paper, the STIM images obtained with an on-axis geometry, a standard off-axis geometry and a recently developed on-off geometry are presented and discussed. Data from skin samples are used for comparison purposes aiming at studying skin permeability to sunscreens. Skin is a stratified tissue and the precise identification of skin layers is needed to ascertain the penetration depth of the physical filter from the formulation. In addition to the intrinsic difference in image quality due to the beam resolution, the influence of the detector type, implanted silicon detector versus Si pin diode, is discussed on the basis of their energy resolution.. their resistance to beam damage as well as the effect
  •  
2.
  • Lekki, J., et al. (författare)
  • On the follicular pathway of percutaneous uptake of nanoparticles: Ion microscopy and autoradiography studies
  • 2007
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 260:1, s. 174-177
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the visualization of the penetration of sunscreen formulations containing TiO2 nanoparticles (about 20 nm primary particle size) into hair follicles of both human and porcine skin using the complementary methods of ion microscopy (PIXE, RBS, STIM) and autoradiography. Particles were found as deep as approx. 400 pin in the follicle, obviously introduced mechanically rather than by a diffusive process. No particles were observed in vital tissue nor in sebaceous glands. (c) 2007 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy