SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kishimoto M) srt2:(2005-2009)"

Sökning: WFRF:(Kishimoto M) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kanai, Y., et al. (författare)
  • Beam test of a prototype phoswich detector assembly for the PoGOLite astronomical soft gamma-ray polarimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 570:1, s. 61-71
  • Tidskriftsartikel (refereegranskat)abstract
    • We report about the beam test on a prototype of the balloon-based astronomical soft gamma-ray polarimeter, PoGOLite (Polarized Gamma-ray Observer-Light Version) conducted at KEK Photon Factory, a synchrotron radiation facility in Japan. The synchrotron beam was set at 30, 50, and 70 keV and its polarization was monitored by a calibrated polarimeter. The goal of the experiment was to validate the flight design of the polarimeter. PoGOLite is designed to measure polarization by detecting a Compton scattering and the subsequent photo-absorption in an array of 217 well-type phoswich detector cells (PDCs). The test setup included a first flight model PDC and a front-end electronics to select and reconstruct valid Compton scattering events. The experiment has verified that the flight PDC can detect recoil electrons and select valid Compton scattering events down to 30 keV from background. The measure azimuthal modulations (34.4%, 35.8% and 37.2% at 30, 50, and 70 keV, respectively) agreed within 10% (relative) with the predictions by Geant4 implemented with dependence on the initial and final photon polarizations.
  •  
2.
  •  
3.
  • Kitano, M, et al. (författare)
  • Ischemia of rat stomach mobilizes ECL cell histamine
  • 2005
  • Ingår i: American Journal of Physiology: Gastrointestinal and Liver Physiology. - : American Physiological Society. - 1522-1547 .- 0193-1857. ; 288:5, s. 1084-1090
  • Tidskriftsartikel (refereegranskat)abstract
    • Microdialysis was used to study how ischemia-evoked gastric mucosal injury affects rat stomach histamine, which resides in enterochromaffin-like (ECL) cells and mast cells. A microdialysis probe was inserted into the gastric submucosa, and the celiac artery was clamped (30 min), followed by removal of the clamp. Microdialysate histamine was determined by enzyme-linked immunosorbent assay. In addition, we studied the long-term effects of ischemia on the oxyntic mucosal histidine decarboxylase activity in omeprazole-treated rats. Gastric mucosal lesions induced by the ischemia were enlarged on removal of the clamp. The microdialysate histamine concentration increased immediately on clamping (50-fold rise within 30 min) and declined promptly after the clamp was removed. In contrast, histidine decarboxylase activity of the ECL cells was lowered by the ischemia and returned to preischemic values 9 days later. Mast cell-deficient rats responded to ischemia-reperfusion much like wild-type rats with respect to histamine mobilization. Pretreatment with the irreversible inhibitor of histidine decarboxylase, alpha-fluoromethylhistidine, which is known to eliminate histamine from ECL cells, prevented the rise in microdialysate histamine. Pharmacological blockade of acid secretion (cimetidine or omeprazole) prevented the lesions induced by ischemia-reperfusion insult but not the mobilization of histamine. In conclusion, ischemia of the celiac artery mobilizes large amounts of histamine from ECL cells, which occurs independently of the gross mucosal lesions. The prompt reduction of the mucosal histidine decarboxylase activity in response to ischemia probably reflects ECL cell damage. The lesions develop not because of mobilization of histamine per se but because of ischemia plus reperfusion plus gastric acid.
  •  
4.
  • Mizuno, T., et al. (författare)
  • A Monte Carlo method for calculating the energy response of plastic scintillators to polarized photons below 100 keV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 600:3, s. 609-617
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy response of plastic scintillators (Eljen Technology EJ-204) to polarized soft gamma-ray photons below 100 keV has been studied, primarily for the balloon-borne polarimeter, PoGOLite. The response calculation includes quenching effects due to low-energy recoil electrons and the position dependence of the light collection efficiency in a 20 cm long scintillator rod. The broadening of the pulse-height spectrum, presumably caused by light transportation processes inside the scintillator, as well as the generation and multiplication of photoelectrons in the photomultiplier tube, were studied experimentally and have also been taken into account. A Monte Carlo simulation based on the Geant4 toolkit was used to model photon interactions in the scintillators. When using the polarized Compton/Rayleigh scattering processes previously corrected by the authors, scintillator spectra and angular distributions of scattered polarized photons could clearly be reproduced, in agreement with the results obtained at a synchrotron beam test conducted at the KEK Photon Factory. Our simulation successfully reproduces the modulation factor, defined as the ratio of the amplitude to the mean of the distribution of the azimuthal scattering angles, within similar to 5% (relative). Although primarily developed for the PoGOLite mission, the method presented here is also relevant for other missions aiming to measure polarization from astronomical objects using plastic scintillator scatterers. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy