SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kluck R) srt2:(2019)"

Sökning: WFRF:(Kluck R) > (2019)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bursill, D., et al. (författare)
  • Gout, Hyperuricaemia and Crystal-Associated Disease Network (G-CAN) consensus statement regarding labels and definitions of disease states of gout
  • 2019
  • Ingår i: Annals of the Rheumatic Diseases. - : BMJ. - 0003-4967 .- 1468-2060. ; 78:11, s. 1592-1600
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective There is a lack of standardisation in the terminology used to describe gout. The aim of this project was to develop a consensus statement describing the recommended nomenclature for disease states of gout. Methods A content analysis of gout-related articles from rheumatology and general internal medicine journals published over a 5-year period identified potential disease states and the labels commonly assigned to them. Based on these findings, experts in gout were invited to participate in a Delphi exercise and face-to-face consensus meeting to reach agreement on disease state labels and definitions. Results The content analysis identified 13 unique disease states and a total of 63 unique labels. The Delphi exercise (n=76 respondents) and face-to-face meeting (n=35 attendees) established consensus agreement for eight disease state labels and definitions. The agreed labels were as follows: 'asymptomatic hyperuricaemia', 'asymptomatic monosodium urate crystal deposition', 'asymptomatic hyperuricaemia with monosodium urate crystal deposition', 'gout', 'tophaceous gout', 'erosive gout', 'first gout flare' and 'recurrent gout flares'. There was consensus agreement that the label 'gout' should be restricted to current or prior clinically evident disease caused by monosodium urate crystal deposition (gout flare, chronic gouty arthritis or subcutaneous tophus). Conclusion Consensus agreement has been established for the labels and definitions of eight gout disease states, including 'gout' itself. The Gout, Hyperuricaemia and Crystal-Associated Disease Network recommends the use of these labels when describing disease states of gout in research and clinical practice.
  •  
2.
  • Abdelhameed, A. H., et al. (författare)
  • Geant4-based electromagnetic background model for the CRESST dark matter experiment
  • 2019
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 79:10
  • Tidskriftsartikel (refereegranskat)abstract
    • The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in CaWO4 crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to (68 +/- 16)% of the electromagnetic background in the energy range between 1 and 40 keV.
  •  
3.
  • Abdelhameed, A. H., et al. (författare)
  • First results from the CRESST-III low-mass dark matter program
  • 2019
  • Ingår i: Physical Review D. - 2470-0010 .- 2470-0029. ; 100:10
  • Tidskriftsartikel (refereegranskat)abstract
    • The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an Earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this paper we describe the analysis of one detector operated in the first run of CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1 eV. This result was obtained with a 23.6 g CaWO4 crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon (heat) signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at similar to 15 mK. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as 160 MeV/c(2).
  •  
4.
  • Abdelhameed, A. H., et al. (författare)
  • First results on sub-GeV spin-dependent dark matter interactions with Li-7
  • 2019
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 79:7
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li2MoO4 target crystal in an above-ground laboratory. Despite the high background environment, the detector sets a competitive limit on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 1.5 GeV/c(2).
  •  
5.
  • Angloher, G., et al. (författare)
  • Limits on dark matter effective field theory parameters with CRESST-II
  • 2019
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 79:1
  • Tidskriftsartikel (refereegranskat)abstract
    • CRESST is a direct dark matter search experiment, aiming for an observation of nuclear recoils induced by the interaction of dark matter particles with cryogenic scintillating calcium tungstate crystals. Instead of confining ourselves to standard spin-independent and spin-dependent searches, we re-analyze data from CRESST-II using a more general effective field theory (EFT) framework. On many of the EFT coupling constants, improved exclusion limits in the low-mass region (< 3–4 GeV/c2) are presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy