SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Koglin Jason)
 

Sökning: WFRF:(Koglin Jason) > (2023) > Speckle contrast of...

Speckle contrast of interfering fluorescence X-rays

Trost, Fabian (författare)
Ayyer, Kartik (författare)
Oberthuer, Dominik (författare)
visa fler...
Yefanov, Oleksandr (författare)
Bajt, Saša (författare)
Caleman, Carl (författare)
Uppsala universitet,Kemisk och biomolekylär fysik,Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
Weimer, Agnes (författare)
Feld, Artur (författare)
Weller, Horst (författare)
Boutet, Sébastien (författare)
Koglin, Jason (författare)
Timneanu, Nicusor (författare)
Uppsala universitet,Kemisk och biomolekylär fysik
von Zanthier, Joachim (författare)
Röhlsberger, Ralf (författare)
Chapman, Henry N. (författare)
Uppsala universitet,Kemisk och biomolekylär fysik,Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany; The Hamburg Center for Ultrafast Imaging, Universität Hamburg; Department of Physics, Universität Hamburg
visa färre...
 (creator_code:org_t)
2023-01-01
2023
Engelska.
Ingår i: Journal of Synchrotron Radiation. - : International Union Of Crystallography. - 0909-0495 .- 1600-5775. ; 30:1, s. 11-23
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focusedX-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

speckle contrast estimation
X-ray fluorescence
incoherent diffraction imaging
XPCS

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy