SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Komorowska K) srt2:(2020-2023)"

Sökning: WFRF:(Komorowska K) > (2020-2023)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Illana, A., et al. (författare)
  • Coulomb excitation of 74,76Zn
  • 2023
  • Ingår i: Physical Review C. - 2469-9985. ; 108:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The first experiment using radioactive beams post-accelerated by the HIE-ISOLDE facility has enabled to obtain a precise set of B(E2) transition probabilities in neutron-rich 74,76Zn isotopes. The resulting B(E2; 2+1→0+1) values are consistent with those determined in earlier REX-ISOLDE measurements. While the B(E2; 4+1→2+1) transition probability in 76Zn is also in agreement with earlier Coulomb-excitation results, the value obtained for 74Zn is considerably lower. For the first time, a spectroscopic quadrupole moment of the 2+1 state was measured for an exotic nucleus in this mass region. A detailed comparison is presented with large-scale shell-model and Monte Carlo shell-model calculations.
  •  
2.
  •  
3.
  • Butler, P. A., et al. (författare)
  • Evolution of Octupole Deformation in Radium Nuclei from Coulomb Excitation of Radioactive ^{222}Ra and ^{228}Ra Beams
  • 2020
  • Ingår i: Physical Review Letters. - 1079-7114. ; 124:4
  • Tidskriftsartikel (refereegranskat)abstract
    • There is sparse direct experimental evidence that atomic nuclei can exhibit stable "pear" shapes arising from strong octupole correlations. In order to investigate the nature of octupole collectivity in radium isotopes, electric octupole (E3) matrix elements have been determined for transitions in ^{222,228}Ra nuclei using the method of sub-barrier, multistep Coulomb excitation. Beams of the radioactive radium isotopes were provided by the HIE-ISOLDE facility at CERN. The observed pattern of E3 matrix elements for different nuclear transitions is explained by describing ^{222}Ra as pear shaped with stable octupole deformation, while ^{228}Ra behaves like an octupole vibrator.
  •  
4.
  • Spagnoletti, P., et al. (författare)
  • Coulomb excitation of Rn 222
  • 2022
  • Ingår i: Physical Review C. - 2469-9985. ; 105:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The nature of quadrupole and octupole collectivity in Rn222 was investigated by determining the electric-quadrupole (E2) and octupole (E3) matrix elements using subbarrier, multistep Coulomb excitation. The radioactive Rn222 beam, accelerated to 4.23 MeV/u, was provided by the HIE-ISOLDE facility at CERN. Data were collected in the Miniball γ-ray spectrometer following the bombardment of two targets, Sn120 and Ni60. Transition E2 matrix elements within the ground-state and octupole bands were measured up to 10ℏ and the results were consistent with a constant intrinsic electric-quadrupole moment, 518(11)efm2. The values of the intrinsic electric-octupole moment for the 0+→3- and 2+→5- transitions were found to be respectively 2360-210+300efm3 and 2300-500+300efm3 while a smaller value, 1200-900+500efm3, was found for the 2+→1- transition. In addition, four excited non-yrast states were identified in this work via γ-γ coincidences.
  •  
5.
  • Andresen Bergström, Moa, 1978, et al. (författare)
  • Rethinking Drug Analysis in Health Care: High-Throughput Analysis of 71 Drugs of Abuse in Oral Fluid Using Ion Mobility-High-Resolution Mass Spectrometry
  • 2022
  • Ingår i: Journal of Analytical Toxicology. - : Oxford University Press (OUP). - 0146-4760 .- 1945-2403. ; 46:7, s. 765-775
  • Tidskriftsartikel (refereegranskat)abstract
    • We have identified a clinical need for a sensitive, specific, flexible, comprehensive and affordable analytical technology to efficiently detect polydrug use. In addition, the current standard practice of surveilled urine sampling is uncomfortable for the patient; hence, more patient-friendly sample collection methods are requested. To fill these needs, we have developed and validated a high-throughput liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method for the analysis of drugs of abuse (DoA) in oral fluid (OF). The method covers a panel of 71 substances including traditional DoA, prescription narcotics and new psychoactive substances (NPS), with a guaranteed limit of identification of <3 mu g/L for 87% of the analytes. Method validation showed high accuracy (>99.7%), sensitivity (>99.7%) and specificity (100%). Most analytes had a high process efficiency during the salting-out liquid-liquid extraction sample preparation and no or only a minor matrix effect during the analysis. We have implemented this method in clinical routine and present data from 18,579 OF samples collected during routine patient treatment in mainly psychiatric and addiction clinics in West Sweden between September 2020 and June 2021. Seventy-one percent of the samples were positive and a total of 41,472 DoA findings were detected. Amphetamine (27%), buprenorphine (25%), nordiazepam (18%) and alprazolam (16%) were most prevalent. New psychoactive substances were detected in 189 samples (1.0%). The occurrence of polydrug use was common; 34% of the positive samples contained three analytes or more and 12% six or more. To the best of our knowledge, this is the first method for comprehensive analysis of DoA in OF using LC-HRMS and the largest dataset published on the detection of DoA in OF. With the current complex and variable drug use pattern, this broad, cost-effective and reliable method has largely replaced immunoassay screening in urine in our laboratory.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy