SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Korecka M.) srt2:(2020-2023)"

Sökning: WFRF:(Korecka M.) > (2020-2023)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Vogel, Jacob W., et al. (författare)
  • Four distinct trajectories of tau deposition identified in Alzheimer’s disease
  • 2021
  • Ingår i: Nature Medicine. - : Springer Science and Business Media LLC. - 1078-8956 .- 1546-170X. ; 27:5, s. 871-881
  • Tidskriftsartikel (refereegranskat)abstract
    • Alzheimer’s disease (AD) is characterized by the spread of tau pathology throughout the cerebral cortex. This spreading pattern was thought to be fairly consistent across individuals, although recent work has demonstrated substantial variability in the population with AD. Using tau-positron emission tomography scans from 1,612 individuals, we identified 4 distinct spatiotemporal trajectories of tau pathology, ranging in prevalence from 18 to 33%. We replicated previously described limbic-predominant and medial temporal lobe-sparing patterns, while also discovering posterior and lateral temporal patterns resembling atypical clinical variants of AD. These ‘subtypes’ were stable during longitudinal follow-up and were replicated in a separate sample using a different radiotracer. The subtypes presented with distinct demographic and cognitive profiles and differing longitudinal outcomes. Additionally, network diffusion models implied that pathology originates and spreads through distinct corticolimbic networks in the different subtypes. Together, our results suggest that variation in tau pathology is common and systematic, perhaps warranting a re-examination of the notion of ‘typical AD’ and a revisiting of tau pathological staging. © 2021, The Author(s), under exclusive licence to Springer Nature America, Inc.
  •  
2.
  • Pannee, Josef, 1979, et al. (författare)
  • The global Alzheimer's Association round robin study on plasma amyloid beta methods
  • 2021
  • Ingår i: Alzheimer's & Dementia. - : Wiley. - 1552-5260 .- 1552-5279. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Blood-based assays to measure brain amyloid beta (A beta) deposition are an attractive alternative to the cerebrospinal fluid (CSF)-based assays currently used in clinical settings. In this study, we examined different blood-based assays to measure A beta and how they compare among centers and assays. Methods Aliquots from 81 plasma samples were distributed to 10 participating centers. Seven immunological assays and four mass-spectrometric methods were used to measure plasma A beta concentrations. Results Correlations were weak for A beta 42 while A beta 40 correlations were stronger. The ratio A beta 42/A beta 40 did not improve the correlations and showed weak correlations. Discussion The poor correlations for A beta 42 in plasma might have several potential explanations, such as the high levels of plasma proteins (compared to CSF), sensitivity to pre-analytical sample handling and specificity, and cross-reactivity of different antibodies. Different methods might also measure different pools of plasma A beta 42. We, however, hypothesize that greater correlations might be seen in future studies because many of the methods have been refined during completion of this study.
  •  
3.
  • Boulo, S., et al. (författare)
  • First amyloid β1-42 certified reference material for re-calibrating commercial immunoassays
  • 2020
  • Ingår i: Alzheimer's and Dementia. - : Wiley. - 1552-5260 .- 1552-5279. ; 16:11, s. 1493-1503
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aβ)1-42 (Aβ42). They are intended to be used to calibrate diagnostic assays for Aβ42. Methods: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. Results: The certified Aβ42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22μg/L, respectively, with expanded uncertainties (k=2) of 0.07, 0.11, and 0.18μg/L, respectively. Before re-calibration, a good correlation (Pearson's r>0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to<5%. Discussion: The Aβ42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aβ42. © 2020 the Alzheimer's Association
  •  
4.
  •  
5.
  • Korecka, Magdalena, et al. (författare)
  • Analytical and Clinical Performance of Amyloid-Beta Peptides Measurements in CSF of ADNIGO/2 Participants by an LC-MS/MS Reference Method.
  • 2020
  • Ingår i: Clinical chemistry. - : Oxford University Press (OUP). - 1530-8561 .- 0009-9147. ; 66:4, s. 587-597
  • Tidskriftsartikel (refereegranskat)abstract
    • Cerebrospinal fluid (CSF) amyloid-β1-42 (Aβ42) reliably detects brain amyloidosis based on its high concordance with plaque burden at autopsy and with amyloid positron emission tomography (PET) ligand retention observed in several studies. Low CSF Aβ42 concentrations in normal aging and dementia are associated with the presence of fibrillary Aβ across brain regions detected by amyloid PET imaging.An LC-MS/MS reference method for Aβ42, modified by adding Aβ40 and Aβ38 peptides to calibrators, was used to analyze 1445 CSF samples from ADNIGO/2 participants. Seventy runs were completed using 2 different lots of calibrators. For preparation of Aβ42 calibrators and controls spiking solution, reference Aβ42 standard with certified concentration was obtained from EC-JRC-IRMM (Belgium). Aβ40 and Aβ38 standards were purchased from rPeptide. Aβ42 calibrators' accuracy was established using CSF-based Aβ42 Certified Reference Materials (CRM).CRM-adjusted Aβ42 calibrator concentrations were calculated using the regression equation Y (CRM-adjusted) = 0.89X (calibrators) + 32.6. Control samples and CSF pools yielded imprecision ranging from 6.5 to 10.2% (Aβ42) and 2.2 to 7.0% (Aβ40). None of the CSF pools showed statistically significant differences in Aβ42 concentrations across 2 different calibrator lots. Comparison of Aβ42 with Aβ42/Aβ40 showed that the ratio improved concordance with concurrent [18F]-florbetapir PET as a measure of fibrillar Aβ (n=766) from 81 to 88%.Long-term performance assessment substantiates our modified LC-MS/MS reference method for 3 Aβ peptides. The improved diagnostic performance of the CSF ratio Aβ42/Aβ40 suggests that Aβ42 and Aβ40 should be measured together and supports the need for an Aβ40 CRM.
  •  
6.
  • Li, Yan, et al. (författare)
  • Validation of Plasma Amyloid-β 42/40 for Detecting Alzheimer Disease Amyloid Plaques
  • 2022
  • Ingår i: Neurology. - 0028-3878. ; 98:7, s. 688-699
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Objectives To determine the diagnostic accuracy of a plasma Aβ42/Aβ40 assay in classifying amyloid PET status across global research studies using samples collected by multiple centers that utilize different blood collection and processing protocols.MethodsPlasma samples (n = 465) were obtained from 3 large Alzheimer disease (AD) research cohorts in the United States (n = 182), Australia (n = 183), and Sweden (n = 100). Plasma Aβ42/Aβ40 was measured by a high precision immunoprecipitation mass spectrometry (IPMS) assay and compared to the reference standards of amyloid PET and CSF Aβ42/Aβ40.ResultsIn the combined cohort of 465 participants, plasma Aβ42/Aβ40 had good concordance with amyloid PET status (receiver operating characteristic area under the curve [AUC] 0.84, 95% confidence interval [CI] 0.80-0.87); concordance improved with the inclusion of APOE ϵ4 carrier status (AUC 0.88, 95% CI 0.85-0.91). The AUC of plasma Aβ42/Aβ40 with CSF amyloid status was 0.85 (95% CI 0.78-0.91) and improved to 0.93 (95% CI 0.89-0.97) with APOE ϵ4 status. These findings were consistent across the 3 cohorts, despite differences in protocols. The assay performed similarly in both cognitively unimpaired and impaired individuals.DiscussionPlasma Aβ42/Aβ40 is a robust measure for detecting amyloid plaques and can be utilized to aid in the diagnosis of AD, identify those at risk for future dementia due to AD, and improve the diversity of populations enrolled in AD research and clinical trials.Classification of EvidenceThis study provides Class II evidence that plasma Aβ42/Aβ40, as measured by a high precision IPMS assay, accurately diagnoses brain amyloidosis in both cognitively unimpaired and impaired research participants.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy