SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Krieger T) srt2:(2020-2023)"

Sökning: WFRF:(Krieger T) > (2020-2023)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
2.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Stroth, U., et al. (författare)
  • Progress from ASDEX Upgrade experiments in preparing the physics basis of ITER operation and DEMO scenario development
  • 2022
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 62:4
  • Tidskriftsartikel (refereegranskat)abstract
    • An overview of recent results obtained at the tokamak ASDEX Upgrade (AUG) is given. A work flow for predictive profile modelling of AUG discharges was established which is able to reproduce experimental H-mode plasma profiles based on engineering parameters only. In the plasma center, theoretical predictions on plasma current redistribution by a dynamo effect were confirmed experimentally. For core transport, the stabilizing effect of fast ion distributions on turbulent transport is shown to be important to explain the core isotope effect and improves the description of hollow low-Z impurity profiles. The L-H power threshold of hydrogen plasmas is not affected by small helium admixtures and it increases continuously from the deuterium to the hydrogen level when the hydrogen concentration is raised from 0 to 100%. One focus of recent campaigns was the search for a fusion relevant integrated plasma scenario without large edge localised modes (ELMs). Results from six different ELM-free confinement regimes are compared with respect to reactor relevance: ELM suppression by magnetic perturbation coils could be attributed to toroidally asymmetric turbulent fluctuations in the vicinity of the separatrix. Stable improved confinement mode plasma phases with a detached inner divertor were obtained using a feedback control of the plasma β. The enhanced D α H-mode regime was extended to higher heating power by feedback controlled radiative cooling with argon. The quasi-coherent exhaust regime was developed into an integrated scenario at high heating power and energy confinement, with a detached divertor and without large ELMs. Small ELMs close to the separatrix lead to peeling-ballooning stability and quasi continuous power exhaust. Helium beam density fluctuation measurements confirm that transport close to the separatrix is important to achieve the different ELM-free regimes. Based on separatrix plasma parameters and interchange-drift-Alfvén turbulence, an analytic model was derived that reproduces the experimentally found important operational boundaries of the density limit and between L- and H-mode confinement. Feedback control for the X-point radiator (XPR) position was established as an important element for divertor detachment control. Stable and detached ELM-free phases with H-mode confinement quality were obtained when the XPR was moved 10 cm above the X-point. Investigations of the plasma in the future flexible snow-flake divertor of AUG by means of first SOLPS-ITER simulations with drifts activated predict beneficial detachment properties and the activation of an additional strike point by the drifts.
  •  
8.
  •  
9.
  •  
10.
  • Broberg, C. S., et al. (författare)
  • Long-Term Outcomes After Atrial Switch Operation for Transposition of the Great Arteries
  • 2022
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097. ; 80:10, s. 951-963
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: For patients with d-loop transposition of the great arteries (d-TGA) with a systemic right ventricle after an atrial switch operation, there is a need to identify risks for end-stage heart failure outcomes. Objectives: The authors aimed to determine factors associated with survival in a large cohort of such individuals. Methods: This multicenter, retrospective cohort study included adults with d-TGA and prior atrial switch surgery seen at a congenital heart center. Clinical data from initial and most recent visits were obtained. The composite primary outcome was death, transplantation, or mechanical circulatory support (MCS). Results: From 1,168 patients (38% female, age at first visit 29 ± 7.2 years) during a median 9.2 years of follow-up, 91 (8.8% per 10 person-years) met the outcome (66 deaths, 19 transplantations, 6 MCS). Patients experiencing sudden/arrhythmic death were younger than those dying of other causes (32.6 ± 6.4 years vs 42.4 ± 6.8 years; P < 0.001). There was a long duration between sentinel clinical events and end-stage heart failure. Age, atrial arrhythmia, pacemaker, biventricular enlargement, systolic dysfunction, and tricuspid regurgitation were all associated with the primary outcome. Independent 5-year predictors of primary outcome were prior ventricular arrhythmia, heart failure admission, complex anatomy, QRS duration >120 ms, and severe right ventricle dysfunction based on echocardiography. Conclusions: For most adults with d-TGA after atrial switch, progress to end-stage heart failure or death is slow. A simplified prediction score for 5-year adverse outcome is derived to help identify those at greatest risk.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy