SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Löf Liza) srt2:(2016)"

Sökning: WFRF:(Löf Liza) > (2016)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Löf, Liza (författare)
  • Applications of in situ proximity ligation assays for cancer research and diagnostics
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • In the field of cancer research and diagnostics it is crucial to have reliable methods for detecting molecules involved in the disease. New and better methods for diagnostics, prognostics and drug delivery therefore remain a permanent aim. In this thesis applications of the in situ proximity ligation assay (in situ PLA) were developed for diagnostics and research. Two new methods were developed, one more cost effective proximity assay without the use of enzymes and one method for loading pharmaceuticals in lipid rafts made from detergent resistant membranes (DRMs) to be used as a drug delivery platform.In Paper I the aim was to develop a flow cytometric detection method of the fusion protein BCR-ABL that is the hallmark of chronic myeloid leukemia (CML). By using in situ PLA the malignant cells carrying the fusion protein could be detected in patients in a convenient workflow.Paper II describes an application of multiplex in situ PLA, where extracellular vesicles (EVs) are detected and identified using flow cytometry. Up to five different antigens are targeted on the EVs, reflected in three different colors during detection in the flow cytometer. By using antibodies targeting proteins specific for prostasomes a population of prostasomes could be identified in human blood plasma.In Paper III a new method is described for using lipid raft for drug delivery. In this method, lipid rafts, derived from prostasomes or erythrocytes, are loaded with pharmaceuticals. The vehicles were loaded with doxorubicin, added to cells and counted. Cells that received the vehicle with doxorubicin stopped proliferating and died, while controls that received the lipid raft vehicle without doxorubicin were not affected, suggesting that the vehicles are effectively loaded with the drug and that they are safe. This lipid raft vehicle could provide a safe drug delivery system.     Paper IV investigates the crosstalk between the two major signal pathways Hippo and Wnt, and how these are affected in gastric cancer. When looking at different colon cancer tumor stages, we found that the cellular localization of TAZ/β-catenin interactions were different. We also found that protein complexes involved in the crosstalk increased in sparsely growing cells compared to more densely growing cells. On the basis of these results the protein E-cadherin, involved in maintenance of the epithelial integrity, was investigated and was found to have a probable role in regulating the crosstalk between Hippo and Wnt.    A new method for localized protein detection is described in paper V. Here a proximity assay, based on the hybridization chain reaction (HCR), was developed. This assay, proxHCR, is more cost effective than in situ PLA because no enzymes are required. ProxHCR successfully detects protein interactions and can be used together with both fluorescence microscopy and flow cytometry.  
  •  
2.
  • Löf, Liza, et al. (författare)
  • Detecting individual extracellular vesicles using a multicolor in situ proximity ligation assay with flow cytometric readout
  • 2016
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Flow cytometry is a powerful method for quantitative and qualitative analysis of individual cells. However, flow cytometric analysis of extracellular vesicles (EVs), and the proteins present on their surfaces has been hampered by the small size of the EVs - in particular for the smallest EVs, which can be as little as 40 nm in diameter, the limited number of antigens present, and their low refractive index. We addressed these limitations for detection and characterization of EV by flow cytometry through the use of multiplex and multicolor in situ proximity ligation assays (in situ PLA), allowing each detected EV to be easily recorded over background noise using a conventional flow cytometer. By targeting sets of proteins on the surface that are specific for distinct classes of EVs, the method allows for selective recognition of populations of EVs in samples containing more than one type of EVs. The method presented herein opens up for analyses of EVs using flow cytometry for their characterization and quantification.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy