SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lamb B) srt2:(2005-2009)"

Sökning: WFRF:(Lamb B) > (2005-2009)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Achterberg, A., et al. (författare)
  • The search for muon neutrinos from northern hemisphere gamma-ray bursts with AMANDA
  • 2008
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 674:1, s. 357-370
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the results of the analysis of neutrino observations by the Antarctic Muon and Neutrino Detector Array (AMANDA) correlated with photon observations of more than 400 gamma-ray bursts (GRBs) in the northern hemisphere from 1997 to 2003. During this time period, AMANDA's effective collection area for muon neutrinos was larger than that of any other existing detector. After the application of various selection criteria to our data, we expect similar to 1 neutrino event and <2 background events. Based on our observations of zero events during and immediately prior to the GRBs in the data set, we set the most stringent upper limit on muon neutrino emission correlated with GRBs. Assuming a Waxman-Bahcall spectrum and incorporating all systematic uncertainties, our flux upper limit has a normalization at 1 PeV of E-2 Phi(nu) <= 6.3 x 10(-9) GeV cm(-2) s(-1) sr(-1), with 90% of the events expected within the energy range of similar to 10 TeV to similar to 3 PeV. The impact of this limit on several theoretical models of GRBs is discussed, as well as the future potential for detection of GRBs by next-generation neutrino telescopes. Finally, we briefly describe several modifications to this analysis in order to apply it to other types of transient point sources.
  •  
2.
  •  
3.
  • Szatmari, Peter, et al. (författare)
  • Mapping autism risk loci using genetic linkage and chromosomal rearrangements.
  • 2007
  • Ingår i: Nature Genetics. - : Springer Science and Business Media LLC. - 1061-4036 .- 1546-1718. ; 39:3, s. 319-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Autism spectrum disorders (ASDs) are common, heritable neurodevelopmental conditions. The genetic architecture of ASDs is complex, requiring large samples to overcome heterogeneity. Here we broaden coverage and sample size relative to other studies of ASDs by using Affymetrix 10K SNP arrays and 1,168 families with at least two affected individuals, performing the largest linkage scan to date while also analyzing copy number variation in these families. Linkage and copy number variation analyses implicate chromosome 11p12-p13 and neurexins, respectively, among other candidate loci. Neurexins team with previously implicated neuroligins for glutamatergic synaptogenesis, highlighting glutamate-related genes as promising candidates for contributing to ASDs.
  •  
4.
  • Carrero, J.J., et al. (författare)
  • Telomere attrition is associated with inflammation, low fetuin : A levels and high mortality in prevalent haemodialysis patients
  • 2008
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 263:3, s. 302-312
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Chronic kidney disease (CKD) predisposes to a 10- to 20-fold increased cardiovascular risk. Patients undergo accelerated atherogenesis and vascular ageing. We investigated whether telomere attrition, a marker of cell senescence, contributes to this increased mortality risk. METHODS: This is a cross-sectional study in prevalent haemodialysis patients [n = 175; 98 Males; median (range) age: 66 (23-86) years]. Biochemical markers of oxidative stress and inflammatory status were measured in relation to the patient's leucocyte telomere length. Overall mortality was assessed after a median of 31 (range 2-42) months. RESULTS: Telomere length was shorter in CKD men, despite women being older (average +/- SD 6.41 +/- 1.23 vs. 6.96 +/- 1.48 kb, P = 0.002). Telomere length was associated with age (rho = -0.18, P = 0.01), fetuin-A (rho = 0.26, P = 0.0004), high-sensitivity C-reactive protein (rho = -0.21, P = 0.005) and IL-6 (rho = -0.17, P = 0.02). In a multivariate logistic regression (pseudo r(2) = 0.14), telomere length was associated with age >65 years (odds ratio: 2.11; 95% CI: 1.10, 4.06), sex (2.01; 1.05, 3.86), fetuin-A (1.85; 0.97, 3.50) and white blood cell count (2.04; 1.02, 4.09). Receiver operating characteristic curves identified a telomere length < 6.28 kb as a fair predictor of mortality. Finally, reduced telomere length was associated with increased mortality, independently of age, gender and inflammation (likelihood ratio 41.6, P < 0.0001), but dependently on fetuin-A levels. CONCLUSION: Age and male gender seem to be important contributors to reduced telomere length in CKD patients, possibly via persistent inflammation. Reduced telomere length also contributes to the mortality risk of these patients through pathways that could involve circulating levels of fetuin-A.
  •  
5.
  • Carroll, M. A., et al. (författare)
  • Reactive nitrogen oxide fluxes to a mixed hardwood forest
  • 2008
  • Ingår i: International Geosphere-Biosphere Programme, Congress in May 2008.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Measurements of NOx (nitric oxide and nitrogen dioxide) mixing ratios and fluxes (20 May – 1 September) and NOy mixing ratios and fluxes (9 August – 1 September) were made at a northern mixed hardwood forest located at the University of Michigan Biological Station in northern Michigan, USA (45.5 deg N, 84.7 deg W, elevation 238 m) in 2005. During the 15-week period of NOx measurements, the site received flow from two dominant flow regimes: the north-northwest (ozone 20 – 40 ppbv) and the south-southwest (ozone 40 – 100 ppbv) approximately 26% and 27% of the time, respectively. Typical ambient NOx and NOy levels ranged from 0.5 – 2.4 ppbv and 0.5 to 3 ppbv, respectively. NO and NOy fluxes were found to be strongly diurnal with mid-day maximum downward fluxes of 0.5 – 2 and 1 – 2 μmole per square meter per hour, respectively, and nighttime fluxes at or near zero. In contrast, NO2 fluxes were small and upward during the morning, small and downward during the afternoon, and at or near zero at night. NOx fluxes were found to be essentially zero throughout the day and night. If all of the NOy deposition in this study were in the form of nitric acid, it would increase the available nutrient nitrate input to the forest by 8% over measured wet nitrate deposition.
  •  
6.
  • Hogg, A., et al. (författare)
  • Multi-year measurements of stomatal and non-stomatal fluxes
  • 2007
  • Ingår i: American Geophysical Union, Meeting in San Francisco, 10–14 December 2007.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Measurements of ozone, sensible heat, and latent heat fluxes, as well as relative humidity, temperature, pressure, wind speed, leaf area index, ambient ozone, and plant physiological parameters were made at a northern mixed hardwood forest located at the University of Michigan Biological Station (UMBS) in northern Michigan during the growing seasons 2002 through 2005. The ozone measurements were used to calculate total ozone flux and partitioning between stomatal and non-stomatal sinks. Total ozone flux varied diurnally with downward flux reaching -100 μmol m-2 h-1 at midday, at or near zero at night. Mean daytime canopy conductance varied over the four years: 0.39 mol m-2 s-1 (2002), 0.41 mol m-2 s-1 (2003), 0.52 mol m-2 s-1 (2004), and 0.43 mol m-2 s-1 (2005). Stomatal conductance showed expected patterns of behavior with respect to photosynthetic photon flux density (PPFD) and vapor pressure deficit (VPD). Estimated peak growing season stomatal ozone burden (flux) was 2.9 x105 nmol m-2 in 2002, 5.6 x105 nmol m-2 in 2003, 6.6 x105 nmol m-2 in 2004, and 4.1 x105 nmol m-2 in 2005. Non-stomatal conductance for ozone increased monotonically with increasing PPFD, and increased with temperature before falling off again at high temperature. Daytime non-stomatal ozone sinks were large and varied with time and environmental drivers. Daytime non-stomatal ozone conductance accounted for as much as 61% (2002), 31% (2003), 36% (2004), or 57% (2005) of canopy conductance, with the non-stomatal partition representing 4.2x105 nmol m-2 (2002), 2.0x105 nmol m-2 (2003), 3.5x105 nmol m-2 (2004), 3.5x105 nmol m-2 (2005) of the flux. Non-stomatal ozone conductance was strongly diurnal and a significant proportion of total canopy conductance.
  •  
7.
  • Hogg, A., et al. (författare)
  • Stomatal and non-stomatal fluxes of ozone to a northern mixed hardwood forest
  • 2007
  • Ingår i: Tellus Series B-Chemical and Physical Meteorology. - 0280-6509. ; 59:3, s. 514-525
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements of ozone, sensible heat, and latent heat fluxes and plant physiological parameters were made at a northern mixed hardwood forest located at the University of Michigan Biological Station in northern Michigan from June 27 to September 28, 2002. These measurements were used to calculate total ozone flux and partitioning between stomatal and non-stomatal sinks. Total ozone flux varied diurnally with maximum values reaching 100 mu mol m(-2) h(-1) at midday and minimums at or near zero at night. Mean daytime canopy conductance was 0.5 mol m(-2) s(-1). During daytime, non-stomatal ozone conductance accounted for as much as 66% of canopy conductance, with the non-stomatal sink representing 63% of the ozone flux. Stomatal conductance showed expected patterns of behaviour with respect to photosynthetic photon flux density (PPFD) and vapour pressure defecit (VPD). Non-stomatal conductance for ozone increased monotonically with increasing PPFD, increased with temperature (T) before falling off again at high T, and behaved similarly for VPD. Day-time non-stomatal ozone sinks are large and vary with time and environmental drivers, particularly PPFD and T. This information is crucial to deriving mechanistic models that can simulate ozone uptake by different vegetation types.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy