SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lambert R) srt2:(2005-2009)"

Sökning: WFRF:(Lambert R) > (2005-2009)

  • Resultat 1-10 av 29
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Santee, M.L., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder HNO3 Measurements
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D24
  • Tidskriftsartikel (refereegranskat)abstract
    • [1] We assess the quality of the version 2.2 (v2.2) HNO(3) measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO(3) product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO(3) data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of similar to 0.7 ppbv throughout. Vertical resolution is 3-4 km in the upper troposphere and lower stratosphere, degrading to similar to 5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO(3) measurements biases that vary with altitude between +/- 0.5 and +/- 2 ppbv and multiplicative errors of +/- 5-15% throughout the stratosphere, rising to similar to +/- 30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO(3) measurements from ground- based, balloon- borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO(3) mixing ratios are uniformly low by 10-30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO(3) values are low in this region as well, but are useful for scientific studies (with appropriate averaging).
  •  
3.
  • Bhattacharya, S, et al. (författare)
  • Public health. The cholera crisis in Africa.
  • 2009
  • Ingår i: Science (New York, N.Y.). - : American Association for the Advancement of Science (AAAS). - 1095-9203 .- 0036-8075. ; 324:5929
  • Forskningsöversikt (refereegranskat)abstract
    • Long-lasting cholera outbreaks in Africa suggest limitations in the current strategy of disease control.
  •  
4.
  • Lambert, A., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder middle atmosphere water vapor and nitrous oxide measurements
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D24
  • Tidskriftsartikel (refereegranskat)abstract
    • The quality of the version 2.2 (v2.2) middle atmosphere water vapor and nitrous oxide measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System (EOS) Aura satellite is assessed. The impacts of the various sources of systematic error are estimated by a comprehensive set of retrieval simulations. Comparisons with correlative data sets from ground-based, balloon and satellite platforms operating in the UV/ visible, infrared and microwave regions of the spectrum are performed. Precision estimates are also validated, and recommendations are given on the data usage. The v2.2 H 2 O data have been improved over v1.5 by providing higher vertical resolution in the lower stratosphere and better precision above the stratopause. The single-profile precision is ∼0.2-0.3 ppmv (4-9%), and the vertical resolution is ∼3-4 km in the stratosphere. The precision and vertical resolution become worse with increasing height above the stratopause. Over the pressure range 0.1-0.01 hPa the precision degrades from 0.4 to 1.1 ppmv (6-34%), and the vertical resolution degrades to ∼12-16 km. The accuracy is estimated to be 0.2-0.5 ppmv (4-11%) for the pressure range 68-0.01 hPa. The scientifically useful range of the H 2 O data is from 316 to 0.002 hPa, although only the 82-0.002 hPa pressure range is validated here. Substantial improvement has been achieved in the v2.2 N 2 O data over v1.5 by reducing a significant low bias in the stratosphere and eliminating unrealistically high biased mixing ratios in the polar regions. The single-profile precision is ∼13-25 ppbv (7-38%), the vertical resolution is ∼4-6 km and the accuracy is estimated to be 3-70 ppbv (9-25%) for the pressure range 100-4.6 hPa. The scientifically useful range of the N 2 O data is from 100 to 1 hPa. Copyright 2007 by the American Geophysical Union.
  •  
5.
  • Santee, M.L., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder ClO Measurements
  • 2008
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 113:D15
  • Tidskriftsartikel (refereegranskat)abstract
    • We assess the quality of the version 2.2 (v2.2) ClO measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS v2.2 ClO data are scientifically useful over the range 100 to 1 hPa, with a single- profile precision of similar to 0.1 ppbv throughout most of the vertical domain. Vertical resolution is similar to 3-4 km. Comparisons with climatology and correlative measurements from a variety of different platforms indicate that both the amplitude and the altitude of the peak in the ClO profile in the upper stratosphere are well determined by MLS. The latitudinal and seasonal variations in the ClO distribution in the lower stratosphere are also well determined, but a substantial negative bias is present in both daytime and nighttime mixing ratios at retrieval levels below (i. e., pressures larger than) 22 hPa. Outside of the winter polar vortices, this negative bias can be eliminated by subtracting gridded or zonal mean nighttime values from the individual daytime measurements. In studies for which knowledge of lower stratospheric ClO mixing ratios inside the winter polar vortices to better than a few tenths of a ppbv is needed, however, day - night differences are not recommended and the negative bias must be corrected for by subtracting the estimated value of the bias from the individual measurements at each affected retrieval level.
  •  
6.
  •  
7.
  •  
8.
  • Goedecke, Julia H, et al. (författare)
  • Differential effects of abdominal adipose tissue distribution on insulin sensitivity in black and white South African women
  • 2009
  • Ingår i: Obesity. - : Wiley. - 1930-7381 .- 1930-739X. ; 17:8, s. 1506-1512
  • Tidskriftsartikel (refereegranskat)abstract
    • Black South African women are more insulin resistant than BMI-matched white women. The objective of the study was to characterize the determinants of insulin sensitivity in black and white South African women matched for BMI. A total of 57 normal-weight (BMI 18-25 kg/m(2)) and obese (BMI > 30 kg/m(2)) black and white premenopausal South African women underwent the following measurements: body composition (dual-energy X-ray absorptiometry), body fat distribution (computerized tomography (CT)), insulin sensitivity (S(I), frequently sampled intravenous glucose tolerance test), dietary intake (food frequency questionnaire), physical activity (Global Physical Activity Questionnaire), and socioeconomic status (SES, demographic questionnaire). Black women were less insulin sensitive (4.4 +/- 0.8 vs. 9.5 +/- 0.8 and 3.0 +/- 0.8 vs. 6.0 +/- 0.8 x 10(-5)/min/(pmol/l), for normal-weight and obese women, respectively, P < 0.001), but had less visceral adipose tissue (VAT) (P = 0.051), more abdominal superficial subcutaneous adipose tissue (SAT) (P = 0.003), lower SES (P < 0.001), and higher dietary fat intake (P = 0.001) than white women matched for BMI. S(I) correlated with deep and superficial SAT in both black (R = -0.594, P = 0.002 and R = 0.495, P = 0.012) and white women (R = -0.554, P = 0.005 and R = -0.546, P = 0.004), but with VAT in white women only (R = -0.534, P = 0.005). In conclusion, body fat distribution is differentially associated with insulin sensitivity in black and white women. Therefore, the different abdominal fat depots may have varying metabolic consequences in women of different ethnic origins.
  •  
9.
  • Goedecke, Julia H, et al. (författare)
  • Insulin response in relation to insulin sensitivity : an appropriate beta-cell response in black South African women.
  • 2009
  • Ingår i: Diabetes Care. - : American Diabetes Association. - 0149-5992 .- 1935-5548. ; 32:5, s. 860-855
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The purpose of this study was to characterize differences in the acute insulin response to glucose (AIR(g)) relative to insulin sensitivity (S(I)) in black and white premenopausal normoglycemic South African women matched for body fatness. RESEARCH DESIGN AND METHODS: Cross-sectional analysis including 57 black and white South African women matched for BMI, S(I), AIR(g), and the disposition index (AIR(g) x S(I)) were performed using a frequently sampled intravenous glucose tolerance test with minimal model analysis, and similar measures were analyzed using an oral glucose tolerance test (OGTT). Body composition was assessed by dual-energy X-ray absorptiometry and computed tomography. RESULTS: S(I) was significantly lower (4.4 +/- 0.8 vs. 9.4 +/- 0.8 and 2.9 +/- 0.8 vs. 6.0 +/- 0. 8 x 10(-5) min(-1)/[pmol/l], P < 0.001) and AIR(g) was significantly higher (1,028 +/- 255 vs. 352 +/- 246 and 1,968 +/- 229 vs. 469 +/- 246 pmol/l, P < 0.001), despite similar body fatness (30.9 +/- 1.4 vs. 29.7 +/- 1.3 and 46.8 +/- 1.2 vs. 44.4 +/- 1.3%) in the normal-weight and obese black women compared with their white counterparts, respectively. Disposition index, a marker of beta-cell function, was not different between ethnic groups (3,811 +/- 538 vs. 2,966 +/- 518 and 3,646 +/- 485 vs. 2,353 +/- 518 x 10(-5) min, P = 0.10). Similar results were obtained for the OGTT-derived measures. CONCLUSIONS: Black South African women are more insulin resistant than their white counterparts but compensate by increasing their insulin response to maintain normal glucose levels, suggesting an appropriate beta-cell response for the level of insulin sensitivity.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 29
Typ av publikation
tidskriftsartikel (20)
konferensbidrag (5)
bokkapitel (2)
proceedings (redaktörskap) (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (26)
övrigt vetenskapligt/konstnärligt (2)
populärvet., debatt m.m. (1)
Författare/redaktör
Fischer, H. (4)
Kumar, R. (4)
Ryk, C. (4)
Murtagh, Donal, 1959 (4)
Urban, Joachim, 1964 (4)
Froidevaux, L. (4)
visa fler...
Livesey, N.J. (4)
Waters, J.W. (4)
LAMBERT, B (4)
Lambert, A (4)
Santee, M. L. (3)
Bernath, P. F. (3)
Daffer, W.H. (3)
Walker, K. A. (3)
De Angelis, M. (3)
Lambert, F. (3)
Boone, C. D. (3)
Read, W.G. (3)
Bigler, M. (3)
Wolff, E. W. (3)
Udisti, R. (3)
Drouin, B. J. (3)
Hou, S. (2)
Tanaka, S. (2)
Fujii, T. (2)
Mori, M. (2)
Jaramillo, E (2)
Larsson, P (2)
Matsuda, T. (2)
Hemminki, K (2)
Olsson, Tommy (2)
Rubio, CA (2)
Triadafilopoulos, G (2)
Seckl, Jonathan R (2)
Walker, Brian R (2)
Berggren, P. (2)
Fujii, H. (2)
Vieth, M (2)
Watanabe, H (2)
Van Gossum, A (2)
Lambert, R. (2)
Shimoda, T (2)
Kahn, Steven E. (2)
Jass, JR (2)
Levitt, Naomi S (2)
Wild, CP (2)
Goedecke, Julia H. (2)
Jung, M. (2)
Masson-Delmotte, V. (2)
Kootstra, Gert, 1978 ... (2)
visa färre...
Lärosäte
Karolinska Institutet (9)
Chalmers tekniska högskola (5)
Stockholms universitet (4)
Umeå universitet (3)
Kungliga Tekniska Högskolan (3)
Göteborgs universitet (2)
visa fler...
Uppsala universitet (2)
Lunds universitet (2)
Luleå tekniska universitet (1)
visa färre...
Språk
Engelska (28)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (7)
Teknik (4)
Medicin och hälsovetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy