SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Leahy A.)
 

Sökning: WFRF:(Leahy A.) > (2002-2004) > Developments in las...

Developments in laser Doppler blood perfusion monitoring

Leahy, M.J. (författare)
Department of Physics, University of Limerick, Limerick, Ireland
De, Mul F.F.M. (författare)
De Mul, F.F.M., Department of Applied Physics, University of Twente, Enschede, Netherlands
Nilsson, G.E. (författare)
Department of Biomedical Engineering, University of Linkoping, Linkoping, Sweden
visa fler...
Maniewski, R. (författare)
Inst. of Biocybernet./Biomed. Eng., Warsaw, Poland
Liebert, A. (författare)
Inst. of Biocybernet./Biomed. Eng., Warsaw, Poland
visa färre...
Department of Physics, University of Limerick, Limerick, Ireland De Mul, FF.M., Department of Applied Physics, University of Twente, Enschede, Netherlands (creator_code:org_t)
SPIE, 2002
2002
Engelska.
Ingår i: Proceedings of SPIE, the International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. ; 4876:1, s. 128-139
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • This paper reviews the development and use of laser Doppler perfusion monitors and imagers. Despite their great success and almost universal applicability in microcirculation research, they have had great difficulty in converting to widespread clinical application. The enormous interest in microvascular blood perfusion coupled with the 'ease of use' of the technique has led to 2000+ publications citing its use. However, useful results can only be achieved with an understanding of the basic principles of the instrumentation and its application in the various clinical disciplines. The basic technical background is explored and definitions of blood perfusion and laser Doppler perfusion are established. The calibration method is then described together with potential routes to standardisation. A guide to the limitations in application of the technique gives the user a clear indication of what can be achieved in new studies as well as possible inadequacy in some published investigations. Finally some clinical applications have found acceptability and these will be explored.

Nyckelord

Biomedical Instrumentation
Blood Supply
Doppler Shift
Laser Doppler Flowmetry
Microcirculation
NATURAL SCIENCES
NATURVETENSKAP

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy