SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindau M) srt2:(2015-2019)"

Sökning: WFRF:(Lindau M) > (2015-2019)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Curbis, F., et al. (författare)
  • Status of the soft X-ray laser (SXL) project at the Max IV laboratory
  • 2019
  • Ingår i: Proceedings of the 39th International Free-Electron Laser Conference, FEL 2019. - : JACoW Publishing. - 9783954502103 ; , s. 749-752
  • Konferensbidrag (refereegranskat)abstract
    • A Soft X-ray Laser project (the SXL) aiming to produce FEL radiation in the range of 1 to 5 nm is currently in a conceptual design phase and a report on the design is expected to be delivered by March 2021. The FEL will be driven by the existing 3 GeV linac at MAX IV laboratory, which also serves as injector for the two storage rings. The science case has been pushed by a large group of mainly Swedish users and consists of experiments ranging from AMO physics to condensed matter, chemistry and imaging in life science. In this contribution, we will present the current conceptual design of the accelerator and the FEL operation modes together with a general overview of the beamline and experimental station. In particular design options for the FEL will be discussed in conjunction with the features of the electron beam from the MAX IV linac and the connection with the proposed experiments. 
  •  
2.
  • Andersen, J., et al. (författare)
  • The soft X-ray laser project at MAX IV
  • 2017
  • Ingår i: IPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference. - : Joint Accelerator Conferences Website - JACoW. - 9783954501823 ; , s. 2760-2762
  • Konferensbidrag (refereegranskat)abstract
    • A Soft X-ray Laser (SXL) beamline utilising FEL technology is being designed for the Short Pulse Facility (SPF) at the MAX IV Laboratory. A conceptual design study has been started following on the scientific case already prepared in collaboration between several Swedish Universities and driven by a strong (Swedish) user demand. The baseline goal of the SXL beamline is to generate intense and short pulses in the range 1-5 nm (0.2-1 keV). The system is building on the MAX IV linac system, already today providing 100 fs 3 GeV and pulses compressed to 100 fs for other applications within the SPF. As a special feature we foresee a variety of pump-probe capabilities. 
  •  
3.
  • Kotur, M, et al. (författare)
  • PHOTOCATHODE LASER PULSE SHAPING FOR IMPROVED EMITTANCE
  • 2018
  • Ingår i: Proceedings of the 29th Linear Accelerator Conference, LINAC 2018. - 9783954501946 ; , s. 84-86
  • Konferensbidrag (refereegranskat)abstract
    • We present a setup for producing and characterizing picosecond ultraviolet laser pulses for use in the MAX IV photocathode electron gun preinjector. Frequency-tripled laser pulses from a commercial laser system are shaped directly in the ultraviolet domain using a Fourier-domain pulse shaper. The pulses were characterized using a transient grating FROG. We discuss a proposed upgrade of the pulse shaper, as well as its limitations.
  •  
4.
  • Kotur, M, et al. (författare)
  • Pulse shaping at the MAX IV photoelectron gun laser
  • 2017
  • Ingår i: IPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference. - 9783954501823 - 9783954501823 ; , s. 1541-1543
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • A motivation for the development of a versatile, programmable source of shaped picosecond pulses for use in photocathode electron gun preinjectors is presented. We present the experimental setup for arbitrary longitudinal pusle shaping of the MAX IV photocathode gun laser. The setup consists of a grating-based Fourier-domain shaper capable of stretching the pulses directly in the UV domain. Preliminary results are presented and discussed.
  •  
5.
  • Lindau, F, et al. (författare)
  • MAX IV Photocathode Gun Laser System Specification and Diagnostics
  • 2017
  • Ingår i: IPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference. - 9783954501823 - 9783954501823 ; , s. 1544-1546
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The MAXIV injector has two guns - a thermionic used for ring injections, and a photocathode used for short pulse facility operation. A commercial Ti:sapphire laser from KMLabs drives the copper based photocathode gun. It has been running without major issues for more than 3 years. The laser delivers up to §I{500}{\textmu J} on the cathode at the third harmonic, §I{263}{nm}, via a vacuum laser transport system. To achieve the desired pulse duration of 2–§I10{ps} the laser pulses, originally ~§I{100}{fs} long, are stretched with a prism pair and the resulting §I{1.5}{ps} pulses stacked by a series of birefringent \textalpha -BBO crystals. Diagnostics consist of photodiodes, spectrometers, and cameras. Longitudinal pulse characterization is done with a cross correlator and a UV FROG.
  •  
6.
  • Andersson, J, et al. (författare)
  • Emittance improvements in the MAX IV photocathode injector
  • 2017
  • Ingår i: IPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference. - 9783954501823 - 9783954501823 ; , s. 1533-1536
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The MAX IV injector design predicts a beam with 100 pC of charge and an emittance lower than 1 mm mrad. The photocathode pre-injector is based on the now close to standard 1.6-cell gun adapted to 2.9985 GHz, in combination with a Ti:Sapphire laser system. This system reaches the requirements of the injector operation for the SPF, but can be tuned beyond specifications to open up new operation modes. During 2016 and 2017 several aspects where investigated to improve the emittance from the current gun, the goal was to meet the SPF specifications. In this paper we report on the progress, discuss the steps taken leading to a final emittance of 1 mm mrad and beyond.
  •  
7.
  • Andersson, J, et al. (författare)
  • The New MAX IV Gun Test Stand
  • 2017
  • Ingår i: IPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference. - 9783954501823 - 9783954501823 ; , s. 1537-1540
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The gun test stand from MAX-Lab has been upgraded and moved to a new facility at the MAX IV Laboratory. The new test stand will reuse parts of the equipment from the old test stand but a number of improvements to the setup are be made. In this paper we report on the design of the new gun test stand, research plans in the near future as well as planned and possible future research topics..
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy