SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindecrantz Kaj) srt2:(2010-2014)"

Sökning: WFRF:(Lindecrantz Kaj) > (2010-2014)

  • Resultat 1-10 av 42
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abtahi, Farhad, 1981- (författare)
  • Aspects of Electrical Bioimpedance Spectrum Estimation
  • 2014
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Electrical bioimpedance spectroscopy (EBIS) has been used to assess the status or composition of various types of tissue, and examples of EBIS include body composition analysis (BCA) and tissue characterisation for skin cancer detection. EBIS is a non-invasive method that has the potential to provide a large amount of information for diagnosis or monitoring purposes, such as the monitoring of pulmonary oedema, i.e., fluid accumulation in the lungs. However, in many cases, systems based on EBIS have not become generally accepted in clinical practice. Possible reasons behind the low acceptance of EBIS could involve inaccurate models; artefacts, such as those from movements; measurement errors; and estimation errors. Previous thoracic EBIS measurements aimed at pulmonary oedema have shown some uncertainties in their results, making it difficult to produce trustworthy monitoring methods. The current research hypothesis was that these uncertainties mostly originate from estimation errors. In particular, time-varying behaviours of the thorax, e.g., respiratory and cardiac activity, can cause estimation errors, which make it tricky to detect the slowly varying behaviour of this system, i.e., pulmonary oedema.The aim of this thesis is to investigate potential sources of estimation error in transthoracic impedance spectroscopy (TIS) for pulmonary oedema detection and to propose methods to prevent or compensate for these errors.   This work is mainly focused on two aspects of impedance spectrum estimation: first, the problems associated with the delay between estimations of spectrum samples in the frequency-sweep technique and second, the influence of undersampling (a result of impedance estimation times) when estimating an EBIS spectrum. The delay between frequency sweeps can produce huge errors when analysing EBIS spectra, but its effect decreases with averaging or low-pass filtering, which is a common and simple method for monitoring the time-invariant behaviour of a system. The results show the importance of the undersampling effect as the main estimation error that can cause uncertainty in TIS measurements.  The best time for dealing with this error is during the design process, when the system can be designed to avoid this error or with the possibility to compensate for the error during analysis. A case study of monitoring pulmonary oedema is used to assess the effect of these two estimation errors. However, the results can be generalised to any case for identifying the slowly varying behaviour of physiological systems that also display higher frequency variations.  Finally, some suggestions for designing an EBIS measurement system and analysis methods to avoid or compensate for these estimation errors are discussed.
  •  
2.
  • Abtahi, Farhad, et al. (författare)
  • Biosignal PI, an Affordable Open-Source ECG and Respiration Measurement System
  • 2014
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 15:1, s. 93-109
  • Tidskriftsartikel (refereegranskat)abstract
    • Bioimedical pilot projects e.g., telemedicine, homecare, animal and human trials usually involve several physiological measurements. Technical development of these projects is time consuming and in particular costly. A versatile but affordable biosignal measurement platform can help to reduce time and risk while keeping the focus on the important goal and making an efficient use of resources. In this work, an affordable and open source platform for development of physiological signals is proposed. As a first step an 8–12 leads electrocardiogram (ECG) and respiration monitoring system is developed. Chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 for patient safety. The result shows the potential of this platform as a base for prototyping compact, affordable, and medically safe measurement systems. Further work involves both hardware and software development to develop modules. These modules may require development of front-ends for other biosignals or just collect data wirelessly from different devices e.g., blood pressure, weight, bioimpedance spectrum, blood glucose, e.g., through Bluetooth. All design and development documents, files and source codes will be available for non-commercial use through project website, BiosignalPI.org.
  •  
3.
  • Abtahi, Farhad, 1981-, et al. (författare)
  • Development and preliminary evaluation of an Android based heart rate variability biofeedback system
  • 2014
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE. - : IEEE. - 9781424479290 ; 2014, s. 3382-5
  • Konferensbidrag (refereegranskat)abstract
    • The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.
  •  
4.
  • Abtahi, Farhad, et al. (författare)
  • Electrical bioimpedance spectroscopy in time-variant systems : Is undersampling always a problem?
  • 2014
  • Ingår i: Journal of Electrical Bioimpedance. - : Walter de Gruyter GmbH. - 1891-5469. ; 5:1, s. 28-33
  • Tidskriftsartikel (refereegranskat)abstract
    • During the last decades, Electrical Bioimpedance Spectroscopy (EBIS) has been applied mainly by using the frequency-sweep technique, across a range of many different applications. Traditionally, the tissue under study is considered to be time-invariant and dynamic changes of tissue activity are ignored by treating the changes as a noise source. A new trend in EBIS is simultaneous electrical stimulation with several frequencies, through the application of a multi-sine, rectangular or other waveform. This method can provide measurements fast enough to sample dynamic changes of different tissues, such as cardiac muscle. This high sampling rate comes at a price of reduction in SNR and the increase in complexity of devices. Although the frequency-sweep technique is often inadequate for monitoring the dynamic changes in a variant system, it can be used successfully in applications focused on the time-invariant or slowly-variant part of a system. However, in order to successfully use frequency-sweep EBIS for monitoring time-variant systems, it is paramount to consider the effects of aliasing and especially the folding of higher frequencies, on the desired frequency e.g. DC level. This paper discusses sub-Nyquist sampling of thoracic EBIS measurements and its application in the case of monitoring pulmonary oedema. It is concluded that by considering aliasing, and with proper implementation of smoothing filters, as well as by using random sampling, frequency-sweep EBIS can be used for assessing time-invariant or slowly-variant properties of time-variant biological systems, even in the presence of aliasing. In general, undersampling is not always a problem, but does always require proper consideration.
  •  
5.
  • Abtahi, Farhad, et al. (författare)
  • Elimination of ECG Artefacts in Foetal EEG Using Ensemble Average Subtraction and Wavelet Denoising Methods : A Simulation
  • 2014
  • Ingår i: XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013. - Cham : Springer. - 9783319008455 ; , s. 551-554
  • Konferensbidrag (refereegranskat)abstract
    • Biological signals recorded from surface electrodes contain interference from other signals which are not desired and should be considered as noise. Heart activity is especially present in EEG and EMG recordings as a noise. In this work, two ECG elimination methods are implemented; ensemble average subtraction (EAS) and wavelet denoising methods. Comparison of these methods has been done by use of simulated signals achieved by adding ECG to neonates EEG. The result shows successful elimination of ECG artifacts by using both methods. In general EAS method which remove estimate of all ECG components from signal is more trustable but it is also harder for implementation due to sensitivity to noise. It is also concluded that EAS behaves like a high-pass filter while wavelet denoising method acts as low-pass filter and hence the choice of one method depends on application.
  •  
6.
  •  
7.
  • Abtahi, Farhad, et al. (författare)
  • Software tool for analysis of breathing-related errors in transthoracic electrical bioimpedance spectroscopy measurements
  • 2012
  • Ingår i: Journal of Physics, Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 407:1, s. 012028-
  • Tidskriftsartikel (refereegranskat)abstract
    • During the last decades, Electrical Bioimpedance Spectroscopy (EBIS) has been applied in a range of different applications and mainly using the frequency sweep-technique. Traditionally the tissue under study is considered to be timeinvariant and dynamic changes of tissue activity are ignored and instead treated as a noise source. This assumption has not been adequately tested and could have a negative impact and limit the accuracy for impedance monitoring systems. In order to successfully use frequency-sweeping EBIS for monitoring time-variant systems, it is paramount to study the effect of frequency-sweep delay on Cole Model-based analysis. In this work, we present a software tool that can be used to simulate the influence of respiration activity in frequency-sweep EBIS measurements of the human thorax and analyse the effects of the different error sources. Preliminary results indicate that the deviation on the EBIS measurement might be significant at any frequency, and especially in the impedance plane. Therefore the impact on Cole-model analysis might be different depending on method applied for Cole parameter estimation.
  •  
8.
  • Atefi, Seyed Reza, 1985-, et al. (författare)
  • Cole Function and Conductance-Based Parasitic Capacitance Compensation for Cerebral Electrical Bioimpedance Measurements
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - San Diego : IEEE press. ; 2012, s. 3368-71
  • Konferensbidrag (refereegranskat)abstract
    • One of the most common measurement artifacts present in Electrical Bioimpedance Spectroscopy measurements (EBIS) comes from the capacitive leakage effect resulting from parasitic stray capacitances. This artifact produces a deviation in the measured impedance spectrum that is most noticeable at higher frequencies. The artifact taints the spectroscopy measurement increasing the difficulty of producing reliable EBIS measurements at high frequencies. In this work, an approach for removing such capacitive influence from the spectral measurement is presented making use of a novel method to estimate the value of the parasitic capacitance equivalent that causes the measurement artifact. The proposed method has been tested and validated theoretically and experimentally and it gives a more accurate estimation of the value of the parasitic capacitance than the previous methods. Once a reliable value of parasitic capacitance has been estimated the capacitive influence can be easily compensated in the EBIS measured data. Thus enabling analysis of EBIS data at higher frequencies, i.e. in the range of 300-500 kHz like measurements intended for cerebral monitoring, where the characteristic frequency is remarkably higher than EBIS measurements i.e. within the range 30 to 50 kHz, intended for body composition assessment.
  •  
9.
  • Atefi, Seyed Reza, 1985-, et al. (författare)
  • Electrical Bioimpedance cerebral monitoring. Preliminary results from measurements on stroke patients
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 126-9
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance Spectroscopy (EBIS) is currently used in different tissue characterization applications. In this work we aim to use EBIS to study changes in electrical properties of the cerebral tissues after an incident of hemorrhage/ischemic stroke. To do so a case-control study was conducted using six controls and three stroke cases. The preliminary results of this study show that by using Cole-based analysis on EBIS measurements and analyzing the Cole parameters R0 and R∞, it is possible to detect changes on electrical properties of cerebral tissue after stroke. 
  •  
10.
  • Atefi, Seyed Reza, et al. (författare)
  • Stroke Damage Detection Using Classification Trees on Electrical Bioimpedance Cerebral Spectroscopy Measurements
  • 2013
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 13:8, s. 10074-10086
  • Tidskriftsartikel (refereegranskat)abstract
    • After cancer and cardio-vascular disease, stroke is the third greatest cause of death worldwide. Given the limitations of the current imaging technologies used for stroke diagnosis, the need for portable non-invasive and less expensive diagnostic tools is crucial. Previous studies have suggested that electrical bioimpedance (EBI) measurements from the head might contain useful clinical information related to changes produced in the cerebral tissue after the onset of stroke. In this study, we recorded 720 EBI Spectroscopy (EBIS) measurements from two different head regions of 18 hemispheres of nine subjects. Three of these subjects had suffered a unilateral haemorrhagic stroke. A number of features based on structural and intrinsic frequency-dependent properties of the cerebral tissue were extracted. These features were then fed into a classification tree. The results show that a full classification of damaged and undamaged cerebral tissue was achieved after three hierarchical classification steps. Lastly, the performance of the classification tree was assessed using Leave-One-Out Cross Validation (LOO-CV). Despite the fact that the results of this study are limited to a small database, and the observations obtained must be verified further with a larger cohort of patients, these findings confirm that EBI measurements contain useful information for assessing on the health of brain tissue after stroke and supports the hypothesis that classification features based on Cole parameters, spectral information and the geometry of EBIS measurements are useful to differentiate between healthy and stroke damaged brain tissue.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 42
Typ av publikation
konferensbidrag (15)
tidskriftsartikel (15)
bokkapitel (4)
licentiatavhandling (4)
doktorsavhandling (3)
patent (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (29)
övrigt vetenskapligt/konstnärligt (12)
populärvet., debatt m.m. (1)
Författare/redaktör
Lindecrantz, Kaj (24)
Seoane, Fernando (18)
Lindecrantz, Kaj, 19 ... (12)
Seoane, Fernando, 19 ... (7)
Lindecrantz, Kaj, Pr ... (6)
Abtahi, Farhad (5)
visa fler...
Kjellmer, Ingemar, 1 ... (3)
Thordstein, Magnus (3)
Buendia, Ruben, 1983 ... (3)
Buendia, Ruben (3)
Seoane Martinez, Fer ... (3)
Flisberg, Anders, 19 ... (3)
Abtahi, Farhad, 1981 ... (2)
Abtahi, Shirin (2)
Sjöqvist, Bengt-Arne ... (2)
Löfgren, Nils, 1969 (2)
Atefi, Seyed Reza, 1 ... (2)
Atefi, Seyed Reza (2)
Seoane Martinéz, Fer ... (2)
Abtahi, F. (1)
Ferreira, J (1)
Aslamy, Benjamin (1)
Seoane, Fernando, As ... (1)
Min, Mart, Professor (1)
Snäll, Jonatan (1)
Berndtsson, Andreas (1)
Löfgren, Nils (1)
Gyllesten, I. C. (1)
Gyllensten, Illapha ... (1)
Johannsson, Gudmundu ... (1)
Bosaeus, Ingvar, 195 ... (1)
Patel, Harshida, 195 ... (1)
Macías, R. (1)
Kjellmer, I (1)
Ellegård, Lars, 1958 (1)
Thordstein, M. (1)
Brodin, Lars-Åke, Pr ... (1)
Wigert, Helena, 1960 (1)
Thorlin, Thorleif (1)
Gil-Pita, R (1)
Bry, Kristina, 1953 (1)
Schaufelberger, Mari ... (1)
Smith, Richard, Prof ... (1)
Sturm, Dennis (1)
Hentz, Elisabet (1)
Buendía López, Rubén ... (1)
Rosell-Ferrer, Javie ... (1)
Buendia, Ruben, 1982 (1)
Ward, L. C. (1)
Löfgren, N. (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (36)
Högskolan i Borås (27)
Karolinska Institutet (20)
Chalmers tekniska högskola (11)
Göteborgs universitet (7)
Linköpings universitet (1)
Språk
Engelska (41)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Teknik (35)
Medicin och hälsovetenskap (17)
Naturvetenskap (2)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy