SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindstrom L.) srt2:(1991-1994)"

Sökning: WFRF:(Lindstrom L.) > (1991-1994)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blad, B., et al. (författare)
  • A current injecting device for electrical impedance tomography
  • 1994
  • Ingår i: Physiological Measurement. - 0967-3334. ; 15:2A
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrical impedance tomography (EIT) has to be improved in order to become an accepted diagnostic technique in clinical use. The aim of this study is to improve the hardware of this technique and preferably upgrade the current injecting device. Instead of using a constant current generator the idea is to implement a voltage source and measure current accurately, in order to improve the resolution in the image. The performance of such a device is analysed, particularly concerning theoretical and practical limitations. The amplitude and phase accuracy, noise and settling time are measured and presented in diagrams. The results show that improvements are possible to achieve and that such a device will improve the stability of an EIT system and the image quality.
  •  
2.
  • Bodlund, Owe, et al. (författare)
  • Axis V--Global Assessment of Functioning Scale. Evaluation of a self-report version
  • 1994
  • Ingår i: Acta Psychiatr Scand. - : Wiley. - 0001-690X .- 0001-690X .- 1600-0447. ; 90:5
  • Tidskriftsartikel (refereegranskat)abstract
    • The present study examines a self-report version of the Global Assessment of Functioning Scale according to Axis V (GAF self-report). The sample (n = 73) was a psychiatric outpatient population from a catchment area clinic. Patients with psychotic and organic mental disorders were not included. The diagnostic distribution on Axis I was similar to the findings from previous studies. Axis II disorders were identified among 47%, of whom a majority also had a concomitant Axis I disorder. The mean GAF expert score was 66.5 (range: 48-86). High complexity and severity of disorders and a high number of fulfilled Axis II criteria were significantly associated with low GAF scores. Independent expert ratings on GAF were correlated with the GAF self-report overall at r = 0.62, varying from 0.45 to 0.91 between different diagnostic groups. In general, the patients scored themselves lower (mean: -4.4 units) than expert ratings. Patients with depressive symptoms from an adjustment disorder or mood disorder were most prone to underestimation. Women also tended to score themselves lower than experts did. Conclusively, the GAF self-report turned out to be a valid and reliable unidimensional instrument measuring psychological, social and occupational functioning. The GAF is easy to handle, and with a self-report version as a complement, Axis V could be more frequently used in future clinical practice and research.
  •  
3.
  • Sandstrom, T, et al. (författare)
  • Inflammatory cell response in bronchoalveolar lavage fluid after nitrogen dioxide exposure of healthy subjects: a dose-response study
  • 1991
  • Ingår i: European Respiratory Journal. - 1399-3003. ; 4:3, s. 332-339
  • Tidskriftsartikel (refereegranskat)abstract
    • The combination of environmental chamber exposure and bronchoalveolar lavage (BAL) was used to study the effects of the common air pollutant nitrogen dioxide (NO2). Eighteen healthy nonsmokers were exposed to NO2 during 20 min in an exposure chamber during light bicycle ergometer work. All subjects were examined with BAL at least 3 wks before exposure, as a reference. The subjects were re-examined with BAL, in groups of eight, 24 h after exposure to 4, 7 and 10 mg NO2.m.3 (2.25, 4.0 and 5.5 ppm), respectively. An inflammatory cell response was found after exposure to all concentrations. An increase in the number of lymphocytes in BAL fluid was observed after 7 and 10 mg.m.3 (p less than 0.05 and 0.02, respectively). An increase in the number of mast cells, that appears to be dose-dependent, was found after exposure to all concentrations. The proportion of lysozyme positive alveolar macrophages was elevated after exposure to 7 mg.m.3. The inflammatory mediators fibronectin, hyaluronan, angiotensin converting enzyme (ACE) and beta 2-microglobulin were unchanged by exposure. Due to the findings of inflammatory cell changes far below the peak exposure limits for work places in industrialized countries, 9-18 mg.m.3, the safety of these limits is questioned. Studies are in progress in our laboratory using BAL to evaluate the effects of repeated NO2 exposure.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy