SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(List A) srt2:(2015-2019)"

Sökning: WFRF:(List A) > (2015-2019)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bergman, A. S., et al. (författare)
  • 280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
  • 2018
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 193:5-6, s. 1075-1084
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be similar to 3 pW at 300 mK with a less than 6% variation across each array at 1 sigma. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
  •  
2.
  • Gualtieri, R., et al. (författare)
  • SPIDER : CMB Polarimetry from the Edge of Space
  • 2018
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 193:5-6, s. 1112-1121
  • Tidskriftsartikel (refereegranskat)abstract
    • SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. Spider targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first long-duration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled transition-edge sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.
  •  
3.
  • Nagy, J. M., et al. (författare)
  • A New Limit on CMB Circular Polarization from SPIDER
  • 2017
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 844:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a new upper limit on cosmic microwave background (CMB) circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for B-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the nonzero circular-to-linear polarization coupling of the half-wave plate polarization modulators, data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes V at 95 and 150 GHz in the range 33 < l < 307. No other limits exist over this full range of angular scales, and SPIDER improves on the previous limit by several orders of magnitude, providing 95% C.L. constraints on l (l + 1)C-l(VV) /(2 pi) ranging from 141 to 255 mu K-2 at 150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments become increasingly sensitive, the techniques described in this paper can be applied to obtain even stronger constraints on circular polarization.
  •  
4.
  • Moortgat-Pick, G., et al. (författare)
  • Physics at the e(+) e(-) linear collider
  • 2015
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 75:8
  • Forskningsöversikt (refereegranskat)abstract
    • A comprehensive review of physics at an e(+) e(-) linear collider in the energy range of root s = 92 GeV-3 TeV is presented in view of recent and expected LHC results, experiments from low-energy as well as astroparticle physics. The report focusses in particular on Higgs-boson, top-quark and electroweak precision physics, but also discusses several models of beyond the standard model physics such as super-symmetry, little Higgs models and extra gauge bosons. The connection to cosmology has been analysed as well.
  •  
5.
  •  
6.
  • Benjamin, Daniel J., et al. (författare)
  • Redefine statistical significance
  • 2018
  • Ingår i: Nature Human Behaviour. - : Nature Research (part of Springer Nature). - 2397-3374. ; 2:1, s. 6-10
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
7.
  •  
8.
  •  
9.
  • Al-Harthy, Mohammad, et al. (författare)
  • Influence of culture on pain comorbidity in women with and without temporomandibular disorder-pain
  • 2017
  • Ingår i: Journal of Oral Rehabilitation. - : John Wiley & Sons. - 1365-2842 .- 0305-182X. ; 44:6, s. 415-425
  • Tidskriftsartikel (refereegranskat)abstract
    • Evidence on cultural differences in prevalence and impact of common chronic pain conditions, comparing individuals with temporomandibular disorders (TMD) versus individuals without TMD, is limited. The aim was to assess cross-cultural comorbid pain conditions in women with chronic TMD pain. Consecutive women patients (n = 122) with the index condition of chronic TMD pain diagnosed per the research diagnostic criteria for TMD and TMD-free controls (n = 121) matched for age were recruited in Saudi Arabia, Italy and Sweden. Self-report questionnaires assessed back, chest, stomach and head pain for prevalence, pain intensity and interference with daily activities. Logistic regression was used for binary variables, and ancova was used for parametric data analysis, adjusting for age and education. Back pain was the only comorbid condition with a different prevalence across cultures; Swedes reported a lower prevalence compared to Saudis (P < 001). Saudis reported higher prevalence of work reduced >50% due to back pain compared to Italians or Swedes (P < 001). Headache was the most common comorbid condition in all three cultures. The total number of comorbid conditions did not differ cross-culturally but were reported more by TMD-pain cases than TMD-free controls (P < 001). For both back and head pain, higher average pain intensities (P < 001) and interference with daily activities (P < 001) were reported by TMD-pain cases, compared to TMD-free controls. Among TMD-pain cases, Italians reported the highest pain-related disability (P < 001). Culture influences the associated comorbidity of common pain conditions. The cultural influence on pain expression is reflected in different patterns of physical representation.
  •  
10.
  • Al-Harthy, Mohammad, et al. (författare)
  • The effect of culture on pain sensitivity
  • 2016
  • Ingår i: Journal of Oral Rehabilitation. - : John Wiley & Sons. - 1365-2842 .- 0305-182X. ; 43:2, s. 81-88
  • Tidskriftsartikel (refereegranskat)abstract
    • Cross-cultural differences in pain sensitivity have been identified in pain-free subjects as well as in chronic pain patients. The aim was to assess the impact of culture on psychophysical measures using mechanical and electrical stimuli in patients with temporomandibular disorder (TMD) pain and pain-free matched controls in three cultures. This case-control study compared 122 female cases of chronic TMD pain (39 Saudis, 41 Swedes and 42 Italians) with equal numbers of age- and gender-matched TMD-free controls. Pressure pain threshold (PPT) and tolerance (PPTo) were measured over one hand and two masticatory muscles. Electrical perception threshold and electrical pain threshold (EPT) and tolerance (EPTo) were recorded between the thumb and index fingers. Italian females reported significantly lower PPT in the masseter muscle than other cultures (P < 0001) and in the temporalis muscle than Saudis (P = 0003). Swedes reported significantly higher PPT in the thenar muscle than other cultures (P = 0017). Italians reported significantly lower PPTo in all muscles than Swedes (P 0006) and in the masseter muscle than Saudis (P < 0001). Italians reported significantly lower EPTo than other cultures (P = 001). Temporomandibular disorder cases, compared to TMD-free controls, reported lower PPT and PPTo in all the three muscles (P < 0001). This study found cultural differences between groups in the PPT, PPTo and EPTo. Overall, Italian females reported the highest sensitivity to both mechanical and electrical stimulation, while Swedes reported the lowest sensitivity. Mechanical pain thresholds differed more across cultures than did electrical pain thresholds. Cultural factors may influence response to type of pain test.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy