SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lu Q M) srt2:(2005-2009)"

Sökning: WFRF:(Lu Q M) > (2005-2009)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
3.
  • Abazov, V. M., et al. (författare)
  • The upgraded DO detector
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 565:2, s. 463-537
  • Tidskriftsartikel (refereegranskat)abstract
    • The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO.
  •  
4.
  • Ablikim, M., et al. (författare)
  • Measurements of (XcJ)-> K+K-K+K- decays
  • 2006
  • Ingår i: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 642:3, s. 197-202
  • Tidskriftsartikel (refereegranskat)abstract
    • Using 14M psi(2S) events taken with the BESII detector, chi(cJ) -> 2(K+K-) decays are studied. For the four-kaon final state, the branching fractions are B(chi(c0,1,2) ->.2(K+K-)) = (3.48 +/- 0.23 +/- 0.47) x 10(-3), (0.70 +/- 0.13 +/- 0.10) x 10(-3), and (2.17 +/- 0.20 +/- 0.31) x 10(-3). For the phi K+K- final state, the branching fractions, which are measured for the first time, are B(chi(c0,1,2) -> phi K+K-) = (1.03 +/- 0.22 +/- 0.15) x 10(-3), (0.46 +/- 0.16 +/- 0.06) x 10(-3), and (1.67 +/- 0.26 +/- 0.24) x 10(-4). For the phi phi final state, B(chi(c0,2) -> phi phi) = (0.94 +/- 0.21 +/- 0.13) x 10(-3) and (1.70 +/- 0.30 +/- 0.25) x 10(-3).
  •  
5.
  • Lu, R, et al. (författare)
  • Genetic associations of LYN with systemic lupus erythematosus
  • 2009
  • Ingår i: Genes and Immunity. - : Springer Science and Business Media LLC. - 1466-4879 .- 1476-5470. ; 10:5, s. 397-403
  • Tidskriftsartikel (refereegranskat)abstract
    • We targeted LYN, a src-tyosine kinase involved in B-cell activation, in case-control association studies using populations of European-American, African-American and Korean subjects. Our combined European-derived population, consisting of 2463 independent cases and 3131 unrelated controls, shows significant association with rs6983130 in a female-only analysis with 2254 cases and 2228 controls (P=1.1 x 10(-4), odds ratio (OR)=0.81 (95% confidence interval: 0.73-0.90)). This single nucleotide polymorphism (SNP) is located in the 5' untranslated region within the first intron near the transcription initiation site of LYN. In addition, SNPs upstream of the first exon also show weak and sporadic association in subsets of the total European-American population. Multivariate logistic regression analysis implicates rs6983130 as a protective factor for systemic lupus erythematosus (SLE) susceptibility when anti-dsDNA, anti-chromatin, anti-52 kDa Ro or anti-Sm autoantibody status were used as covariates. Subset analysis of the European-American female cases by American College of Rheumatology classification criteria shows a reduction in the risk of hematological disorder with rs6983130 compared with cases without hematological disorders (P=1.5 x 10(-3), OR=0.75 (95% CI: 0.62-0.89)). None of the 90 SNPs tested show significant association with SLE in the African American or Korean populations. These results support an association of LYN with European-derived individuals with SLE, especially within autoantibody or clinical subsets.
  •  
6.
  • Hu, Q.M., et al. (författare)
  • Effect of Zr on the properties of (TiZr)Ni alloys from first-principles calculations
  • 2007
  • Ingår i: Physical Review B. - 0163-1829. ; 76:22, s. 224201-
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of Zr on the martensitic transformation (MT) behavior and mechanical properties of (Ti(0.5-x)Zr(x))Ni(0.5) alloys is investigated by calculating the elastic constants and elastic moduli in the B2 phase as a function of x for 0 <= x <= 0.2. The calculations are performed using the coherent potential approximation implemented within the framework of the exact muffin-tin orbitals method. We find that the theoretical elastic properties correlate well with the behavior of the MT. With increasing Zr concentration, the anisotropy of the alloy decreases, indicating that the nonbasal plane shear on which the modulus C(44) plays an important role, dominates and, therefore, a monoclinic martensitic phase should result. The experimental Zr content dependence of the MT temperature is paralleled with the calculated C(44) versus Zr content. The theoretical elastic moduli demonstrate that the (TiZr)Ni alloys, with Zr distributed randomly on the Ti sublattice, are intrinsically ductile, which suggests that the poor ductility of these alloys may be ascribed to some other factors, for example, impurities, precipitation, and grain boundaries.
  •  
7.
  • Qiu, X. Y., et al. (författare)
  • Room-temperature weak ferromagnetism of amorphous HfAlOx thin films deposited by pulsed laser deposition
  • 2006
  • Ingår i: Applied Physics Letters. - : American Institute of Physics (AIP). - 0003-6951 .- 1077-3118. ; 89:24, s. 242504-
  • Tidskriftsartikel (refereegranskat)abstract
    • The room-temperature weak ferromagnetism of amorphous HfAlOx thin films deposited by pulsed laser deposition on various substrates in oxygen-defective ambient is demonstrated. The magnetization is independent of film thickness, but depends on substrates and deposition temperatures. A magnetic moment of similar to 0.26 mu(B) per HfAlOx f.u. is recorded for HfAlOx films deposited under optimized conditions [deposited at 600 degrees C on (001) sapphire in high vacuum]. It is argued that interfacial defects are one of the possible sources of the weak ferromagnetism. (c) 2006 American Institute of Physics.
  •  
8.
  •  
9.
  • Niklaus, Frank, et al. (författare)
  • Effects of bonding process parameters on wafer-to-wafer alignment accuracy in benzocyclobutene (BCB) dielectric wafer bonding
  • 2005
  • Ingår i: Materials, Technology and Reliability of Advanced Interconnects-2005. - WARRENDALE, PA : MATERIALS RESEARCH SOCIETY. - 1558998160 ; , s. 393-398
  • Konferensbidrag (refereegranskat)abstract
    • Wafer-level three-dimensional (3D) integration is an emerging technology to increase the performance and functionality of integrated circuits (ICs). Aligned wafer-to-wafer bonding with dielectric polymer layers (e.g., benzocyclobutene (BCB)) is a promising approach for manufacturing of 3D ICs, with minimum bonding impact on the wafer-to-wafer alignment accuracy essential. In this paper we investigate the effects of thermal and mechanical bonding parameters on the achievable post-bonding wafer-to-wafer alignment accuracy for polymer wafer bonding with 200 trim diameter wafers. Our baseline wafer bonding process with soft-baked BCB (similar to 35% cross-linked) has been modified to use partially cured (similar to 43% crosslinked) BCB. The partially cured BCB layer does not reflow during bonding, minimizing the impact of inhomogeneities in BCB reflow under compression and/or slight shear forces at the bonding interface. As a result, the non-uniformity of the BCB layer thickness after wafer bonding is less than 0.5% of the nominal layer thickness and the wafer shift relative to each other during the wafer bonding process is less than 1 mu m (average) for 200 mm diameter wafers. The critical adhesion energy of a bonded wafer pair with the partially cured BCB wafer bonding process is similar to that with soft-baked BCB.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy