SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Månsson Viktor)
 

Sökning: WFRF:(Månsson Viktor) > (2015) > Identification of H...

Identification of Haemophilus influenzae type b isolates by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry

Månsson, Viktor (författare)
Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
Resman, Fredrik (författare)
Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
Kostrzewa, Markus (författare)
Bruker Daltonik GmbH
visa fler...
Nilson, Bo (författare)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
Riesbeck, Kristian (författare)
Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: Journal of Clinical Microbiology. - 1098-660X. ; 53:7, s. 2215-2224
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Haemophilus influenzae type b (Hib) is, in contrast to non-b H. influenzae, associated with severe invasive disease such as meningitis and epiglottitis in small children. To date accurate H. influenzae capsule typing requires PCR, a time-consuming and cumbersome method. MALDI-TOF MS provides rapid bacterial diagnostics and is increasingly used in clinical microbiology laboratories. Here MALDI-TOF MS was evaluated as a novel approach to separate Hib from other H. influenzae. PCR-verified Hib and non-Hib reference isolates were selected based on genetic and spectral characteristics. Mass spectra of reference isolates were acquired, and used to generate different classification algorithms for Hib/non-Hib separation using both ClinProTools and MALDI Biotyper software. A test series of mass spectra from 33 Hib and 77 non-Hib isolates, all characterized by PCR, was used to evaluate the algorithms. Several algorithms yielded good results but the two best were a ClinProTools model based on 22 separating peaks and a subtyping main spectra (MSP) model using MALDI Biotyper. The ClinProTools model had a sensitivity of 100%, a specificity of 99% and the results were 98% reproducible using a different MALDI-TOF MS instrument. The Biotyper subtyping MSPs had a sensitivity of 97%, a specificity of 100% and 93% reproducibility. Our results suggest that it is possible to use MALDI-TOF MS to differentiate Hib from other H. influenzae. This is a promising method to rapidly identify Hib in unvaccinated populations, and for screening or surveillance of Hib carriage in vaccinated populations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Mikrobiologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Microbiology in the medical area (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy