Sökning: WFRF:(Månsson Viktor)
> (2015) >
Identification of H...
Identification of Haemophilus influenzae type b isolates by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry
-
- Månsson, Viktor (författare)
- Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
-
- Resman, Fredrik (författare)
- Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
-
- Kostrzewa, Markus (författare)
- Bruker Daltonik GmbH
-
visa fler...
-
- Nilson, Bo (författare)
- Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
-
- Riesbeck, Kristian (författare)
- Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
-
visa färre...
-
(creator_code:org_t)
- 2015
- 2015
- Engelska.
-
Ingår i: Journal of Clinical Microbiology. - 1098-660X. ; 53:7, s. 2215-2224
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Haemophilus influenzae type b (Hib) is, in contrast to non-b H. influenzae, associated with severe invasive disease such as meningitis and epiglottitis in small children. To date accurate H. influenzae capsule typing requires PCR, a time-consuming and cumbersome method. MALDI-TOF MS provides rapid bacterial diagnostics and is increasingly used in clinical microbiology laboratories. Here MALDI-TOF MS was evaluated as a novel approach to separate Hib from other H. influenzae. PCR-verified Hib and non-Hib reference isolates were selected based on genetic and spectral characteristics. Mass spectra of reference isolates were acquired, and used to generate different classification algorithms for Hib/non-Hib separation using both ClinProTools and MALDI Biotyper software. A test series of mass spectra from 33 Hib and 77 non-Hib isolates, all characterized by PCR, was used to evaluate the algorithms. Several algorithms yielded good results but the two best were a ClinProTools model based on 22 separating peaks and a subtyping main spectra (MSP) model using MALDI Biotyper. The ClinProTools model had a sensitivity of 100%, a specificity of 99% and the results were 98% reproducible using a different MALDI-TOF MS instrument. The Biotyper subtyping MSPs had a sensitivity of 97%, a specificity of 100% and 93% reproducibility. Our results suggest that it is possible to use MALDI-TOF MS to differentiate Hib from other H. influenzae. This is a promising method to rapidly identify Hib in unvaccinated populations, and for screening or surveillance of Hib carriage in vaccinated populations.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Mikrobiologi inom det medicinska området (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Microbiology in the medical area (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas