SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Maguire K.)
 

Sökning: WFRF:(Maguire K.) > (1995-1999) > Warping CT scans fr...

Warping CT scans from nontreatment to treatment position

Galvin, J. M. (författare)
New York University
Han, K. (författare)
Noz, Marilyn E. (författare)
New York University
visa fler...
Vaccaro, T. (författare)
Cooper, J. (författare)
New York University
Reddy, David P. (författare)
Maguire Jr., Gerald Q. (författare)
KTH,Teleinformatik
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Radiation oncology investigations (Print). - 1065-7541 .- 1520-6823. ; 5:4, s. 206-212
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper describes a cost-effective technique that optimally utilizes all available diagnostic studies for three-dimensional treatment planning. A simulator unit modified to produce cross-sectional images {(simulator-CT} unit) is used to create a reference data set with the patient in the treatment position. Registration software (qsh) brings other diagnostic studies into agreement with this reference data set. Two cases are presented as examples of the use of this technique. Registration of abdominal scans from the same patient demonstrates the warping of a nontreatment position study to the treatment position. The second case is based on paired data sets through the head, in which the diagnostic study was obtained by using a gantry tilt to follow the base of the skull and to avoid sections passing through the teeth. The registration software provides a method for combining diagnostic studies into a single "master" data set. The success of the transformation depends on the operator's ability to identify corresponding anatomic landmarks for different data sets and on the magnitude of the variation in the patient's position from one procedure to the next. Limitations in image quality and the number of cross-sections obtainable from a {simulator-CT} unit can be partially overcome by using the described technique. Thus, the information contained in nontreatment position diagnostic tests can be used accurately for treatment planning at limited cost.

Nyckelord

CT simulation
Image warping
Simulation CT
Three-dimensional treatment planning
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy