Clinical and radiographic evaluation of early loaded narrow diameter implants - 1-year follow-up

Galindo-Moreno, Pablo (författare)
Nilsson, Peter (författare)
King, Paul (författare)
visa fler...
Becktor, Jonas P (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Speroni, Stefano (författare)
Schramm, Alexander (författare)
Maiorana, Carlo (författare)
visa färre...
 (creator_code:org_t)
2011-09-28
2012
Engelska.
Ingår i: Clinical Oral Implants Research. - : John Wiley & Sons. - 0905-7161 .- 1600-0501. ; 23:5, s. 609-616
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: To evaluate the clinical performance of Astra Tech OsseoSpeed™ TX 3.0S implants using one‐stage surgical procedure and early loading in the anterior region. Material and methods: This is a prospective, single arm, multi‐centre study. Patients missing teeth at positions 12, 22 and 32–42 were eligible to enter the study. The implants (OsseoSpeed™ TX 3.0S) used in the study were of 3 mm diameter and of different lengths. One‐stage surgery was performed, and healing abutments were used during the 6–10 weeks healing period. Clinical and radiographic examinations were assessed at implant installation, loading and at the 6‐ and 12‐month follow‐up visits. Results: Ninety‐seven implants were placed in 69 patients at six different study centres in Denmark, Germany, Italy, Spain, Sweden and the United Kingdom. The survival rate was 95.9%. No implants have been lost after loading (100% survival rate after loading). Mean marginal bone loss 1 year after installation was 0.065 mm (SD = 1.018). The frequency of bone loss ≥1 mm was 6.6% and 51.3% of the implants demonstrated no bone loss or even bone gain from the surgical visit to the first year follow‐up visit. Mean probing pocket depth and gingival zenith score were stable from crown placement to the 6‐ and 1‐year follow‐up visits. Conclusion: Treatment with OsseoSpeed™ TX 3.0S implants is a safe and predictable option in the anterior region where physical space is limited. Minimal marginal bone loss was observed during the first year follow‐up.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Adolescent
Adult
Aged
Alveolar Bone Loss
Antibiotic Prophylaxis
Dental Implants
Dental Prosthesis Design
Dental Restoration Failure
Female
Follow-Up Studies
Humans
Immediate Dental Implant Loading
Jaw
Edentulous
Partially
Male
Middle Aged
Prospective Studies
Radiography
Survival Rate
Treatment Outcome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy