1.
  • Xu, Xingxing, et al. (författare)
  • Revisiting the factors influencing gold electrodes prepared using cyclic voltammetry
  • 2019
  • Ingår i: Sensors and actuators. B, Chemical. - : Elsevier BV. - 0925-4005 .- 1873-3077. ; 283, s. 146-153
  • Tidskriftsartikel (refereegranskat)abstract
    • Gold is widely used as the electrode material in different chemi- and biosensing applications while cyclic voltammetry (CV) in sulfuric acid solutions is a commonly employed method for gold surface preparation and characterization. However, as shown herein, chloride leakage from the Ag/AgCl/sat. KCl reference electrode and platinum dissolution from the platinum counter electrode can severely compromise the reproducibility and hence the reliability of the prepared gold electrodes. The aim of this work is to obtain a comprehensive understanding of the separate and interdependent effects of the aforementioned factors on the voltammetric behavior of microfabricated polycrystalline gold electrodes. It is shown that the leakage of chloride gives rise to etching of both the gold working and the platinum counter electrodes and that the chloride concentration has a strong influence on the ratio between the obtained gold and platinum concentrations in the electrolyte. The dissolved gold and platinum are then re-deposited on the gold electrode on the cathodic voltammetric scan, changing the structure and properties of the electrode. It is also demonstrated that the changes in the properties of the gold electrode are determined by the ratio between the co-deposited platinum and gold rather than the absolute amount of platinum deposited on the gold electrode. In addition, the chloride and sulfate adsorption behavior on the gold electrode is carefully investigated. It is proposed that redox peaks due to the formation ofthe corresponding Au(I) complexes can be seen in the double layer region of the voltammogram. The results show that the chloride leakage from the reference electrode needs to be carefully controlled and that platinum counter electrodes should be avoided when developing gold sensing electrodes. The present comprehensive understanding of the electrochemical performance of gold electrodes prepared using CV should be of significant importance in conjunction with both fundamental investigations and practical applications.
  •  
2.
  • Xu, Xingxing, et al. (författare)
  • Structural Changes of Mercaptohexanol Self-assembled Monolayers on Gold and their Influence on Impedimetric Aptamer Sensors
  • 2019
  • Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 91:22, s. 14697-14704
  • Tidskriftsartikel (refereegranskat)abstract
    • Despite a large number of publications describing biosensors based on electrochemical impedance spectroscopy (EIS), little attention has been paid to the stability and reproducibility issues of the sensor interfaces. In this work, the stability and reproducibility of faradaic EIS analyses on the aptamer/mercaptohexanol (MCH) self-assembled monolayer (SAM) functionalized gold surfaces in ferri- and ferrocyanide solution were systematically evaluated prior to and after the aptamer-probe DNA hybridization. It is shown that the EIS data exhibited significant drift, and this significantly affected the reproducibility of the EIS signal of the hybridization. As a result, no significant difference between the charge transfer resistance (RCT) changes induced by the aptamer-target DNA hybridization and that caused by the drift could be identified. A conditioning of the electrode in the measurement solution for more than 12 hours was required to reach a stable RCT baseline prior to the aptamer-probe DNA hybridization. The monitored drift in RCT and CDL during the conditioning suggests that the MCH SAM on the gold surface reorganized to a thinner but more closely packed layer. We also observed that the hot binding buffer used in the following aptamer-probe DNA hybridization process could induce additional MCH and aptamer reorganization thus further drift in RCT. As a result, the RCT change caused by the aptamer-probe DNA hybridization was less than that caused by the hot binding buffer (blank control experiment). Therefore, it is suggested that the use of high temperature in the EIS measurement should be carefully evaluated or avoided. This work provides practical guidelines for the EIS measurements. Moreover, since SAM functionalized gold electrodes are widely used in biosensors, e.g., DNA sensors, an improved understanding of the origin of the observed drift is very important for the development of well-functioning and reproducible biosensors.
  •  