SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Martini S. M. S.) srt2:(2005-2009)"

Sökning: WFRF:(Martini S. M. S.) > (2005-2009)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
2.
  • Lorenzini, R., et al. (författare)
  • Self-organized helical equilibria as a new paradigm for ohmically heated fusion plasmas
  • 2009
  • Ingår i: Nature Physics. - : Springer Science and Business Media LLC. - 1745-2473 .- 1745-2481. ; 5:8, s. 570-574
  • Tidskriftsartikel (refereegranskat)abstract
    • In the quest for new energy sources, the research on controlled thermonuclear fusion has been boosted by the start of the construction phase of the International Thermonuclear Experimental Reactor (ITER). ITER is based on the tokamak magnetic configuration, which is the best performing one in terms of energy confinement. Alternative concepts are however actively researched, which in the long term could be considered for a second generation of reactors. Here, we show results concerning one of these configurations, the reversed-field pinch (RFP). By increasing the plasma current, a spontaneous transition to a helical equilibrium occurs, with a change of magnetic topology. Partially conserved magnetic flux surfaces emerge within residual magnetic chaos, resulting in the onset of a transport barrier. This is a structural change and sheds new light on the potential of the RFP as the basis for a low-magnetic-field ohmic fusion reactor.
  •  
3.
  • Martin, P., et al. (författare)
  • Overview of RFX-mod results
  • 2009
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 49:10, s. 104019-
  • Tidskriftsartikel (refereegranskat)abstract
    • With the exploration of the MA plasma current regime in up to 0.5 s long discharges, RFX-mod has opened new and very promising perspectives for the reversed field pinch (RFP) magnetic configuration, and has made significant progress in understanding and improving confinement and in controlling plasma stability. A big leap with respect to previous knowledge and expectations on RFP physics and performance has been made by RFX-mod since the last 2006 IAEA Fusion Energy Conference. A new self-organized helical equilibrium has been experimentally achieved ( the Single Helical Axis-SHAx-state), which is the preferred state at high current. Strong core electron transport barriers characterize this regime, with electron temperature gradients comparable to those achieved in tokamaks, and by a factor of 4 improvement in confinement time with respect to the standard RFP. RFX-mod is also providing leading edge results on real-time feedback control of MHD instabilities, of general interest for the fusion community.
  •  
4.
  • Puiatti, M. E., et al. (författare)
  • Helical equilibria and magnetic structures in the reversed field pinch and analogies to the tokamak and stellarator
  • 2009
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 51:12, s. 124031-
  • Tidskriftsartikel (refereegranskat)abstract
    • The reversed field pinch configuration is characterized by the presence of magnetic structures both in the core and at the edge: in the core, at high plasma current the spontaneous development of a helical structure is accompanied by the appearance of internal electron transport barriers; at the edge strong pressure gradients, identifying an edge transport barrier, are observed too, related to the position of the field reversal surface. The aim of this paper is the experimental characterization of both the internal and edge transport barriers in relation to the magnetic topology, discussing possible analogies and differences with other confinement schemes.
  •  
5.
  • Ruperto, N., et al. (författare)
  • PRINTO/PRES international website for families of children with rheumatic diseases: www.pediatric-rheumatology.printo.it
  • 2005
  • Ingår i: Ann Rheum Dis. - : BMJ. - 0003-4967. ; 64:7, s. 1101-6
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To prepare a website for families and health professionals containing up to date information about paediatric rheumatic diseases (PRD). METHODS: Firstly, paediatric rheumatology centres and family self help associations were surveyed to characterise current clinical practice of physicians providing care for children with PRD, research activities, and training facilities of each centre. Secondly, international consensus was reached on the content of the website. Finally, the website was developed and the texts translated. RESULTS: The web page contains three main sections: (a) description for families of the characteristics of 15 PRD; (b) list of paediatric rheumatology centres; (c) contact information for family self help associations. A version for 45 countries in 52 languages (with another three in progress) is now available on the web. 291 surveys from 171 centres and 102 family associations were received from 42 countries. The median proportion of time spent in paediatric practice in the centres examined was 100%, with 70% of this time dedicated to paediatric rheumatology. 90% of the centres were willing to perform clinical trials in the future. CONCLUSIONS: The PRINTO/PRES website provides a well defined and competent set of information about PRD, with appropriate multiple translated versions and easy web navigational direction.
  •  
6.
  • Ruperto, N., et al. (författare)
  • The Pediatric Rheumatology International Trials Organization/American College of Rheumatology provisional criteria for the evaluation of response to therapy in juvenile systemic lupus erythematosus : prospective validation of the definition of improvement
  • 2006
  • Ingår i: Arthritis and Rheumatism. - : Wiley. - 0004-3591 .- 1529-0131. ; 55:3, s. 355-363
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To use the Pediatric Rheumatology International Trials Organization (PRINTO) core set of outcome measures to develop a validated definition of improvement for the evaluation of response to therapy in juvenile systemic lupus erythematosus (SLE).METHODS: Thirty-seven experienced pediatric rheumatologists from 27 countries, each of whom had specific experience in the assessment of juvenile SLE patients, achieved consensus on 128 patient profiles as being clinically improved or not improved. Using the physicians' consensus ratings as the gold standard measure, the chi-square, sensitivity, specificity, false-positive and false-negative rates, area under the receiver operating characteristic curve, and kappa level of agreement for 597 candidate definitions of improvement were calculated. Only definitions with a kappa value greater than 0.7 were retained. The top definitions were selected based on the product of the content validity score multiplied by its kappa statistic.RESULTS: The definition of improvement with the highest final score was at least 50% improvement from baseline in any 2 of the 5 core set measures, with no more than 1 of the remaining worsening by more than 30%.CONCLUSION: PRINTO proposes a valid and reproducible definition of improvement that reflects well the consensus rating of experienced clinicians and that incorporates clinically meaningful change in core set measures in a composite end point for the evaluation of global response to therapy in patients with juvenile SLE. The definition is now proposed for use in juvenile SLE clinical trials and may help physicians to decide whether a child with SLE responded adequately to therapy.
  •  
7.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of neutron detection efficiency in lead-scintillating fiber calorimeters
  • 2009
  • Ingår i: Nuclear physics B, Proceedings supplements. - : Elsevier BV. - 0920-5632 .- 1873-3832. ; 197:1, s. 353-357
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE lead-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range [5-175] MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 30% to 50%. This value largely exceeds the estimated 8-15% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. First data-MC comparisons are encouraging and allow to disentangle a neutron halo component in the beam.
  •  
8.
  • Anelli, M., et al. (författare)
  • Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 598:1, s. 244-247
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration.
  •  
9.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 581:1-2, s. 368-372
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range 5-175 MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 40% to 50%. This value largely exceeds the estimated 8-16% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented, as well as a first data Monte Carlo comparison. The results show an overall neutron efficiency of about 50%, when no trigger threshold is applied. The reasons of such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
10.
  • Ruperto, N., et al. (författare)
  • A randomized, placebo-controlled trial of infliximab plus methotrexate for the treatment of polyarticular-course juvenile rheumatoid arthritis
  • 2007
  • Ingår i: Arthritis Rheum. - : Wiley. - 0004-3591. ; 56:9, s. 3096-3106
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate the safety and efficacy of infliximab in the treatment of juvenile rheumatoid arthritis (JRA). METHODS: This was an international, multicenter, randomized, placebo-controlled, double-blind study. One hundred twenty-two children with persistent polyarticular JRA despite prior methotrexate (MTX) therapy were randomized to receive infliximab or placebo for 14 weeks, after which all children received infliximab through week 44. Patients received MTX plus infliximab 3 mg/kg through week 44, or MTX plus placebo for 14 weeks followed by MTX plus infliximab 6 mg/kg through week 44. RESULTS: Although a higher proportion of patients in the 3 mg/kg infliximab group than in the placebo group had achieved responses according to the American College of Rheumatology (ACR) Pediatric 30 (Pedi 30) criteria for improvement at week 14 (63.8% and 49.2%, respectively), the between-group difference in this primary efficacy end point was not statistically significant (P = 0.12). By week 16, after the crossover from placebo to infliximab 6 mg/kg when all patients were receiving infliximab, an ACR Pedi 30 response was achieved in 73.2% of all patients. By week 52, ACR Pedi 50 and ACR Pedi 70 responses had been reached in 69.6% and 51.8%, respectively, of patients. Infliximab was generally well tolerated, but the safety profile of infliximab 3 mg/kg appeared less favorable than that of infliximab 6 mg/kg, with more frequent occurrences of serious adverse events, infusion reactions, antibodies to infliximab, and newly induced antinuclear antibodies and antibodies to double-stranded DNA observed with the 3 mg/kg dose. CONCLUSION: While infliximab at 3 mg/kg and 6 mg/kg showed durable efficacy at 1 year, achievement of the primary efficacy end point at 3 months did not differ significantly between infliximab-treated and placebo-treated patients. Safety data indicated that the 6-mg/kg dose may provide a more favorable risk/benefit profile. These results warrant further investigation in children with JRA.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy