SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mauri F) srt2:(2005-2009)"

Sökning: WFRF:(Mauri F) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Pittori, C., et al. (författare)
  • First AGILE catalog of high-confidence gamma-ray sources
  • 2009
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 506:3, s. 1563-1574
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first catalog of high-confidence gamma-ray sources detected by the AGILE satellite during observations performed from July 9, 2007 to June 30, 2008. Cataloged sources were detected by merging all the available data over the entire time period. AGILE, launched in April 2007, is an ASI mission devoted to gamma-ray observations in the 30 MeV-50 GeV energy range, with simultaneous X-ray imaging capability in the 18-60 keV band. This catalog is based on Gamma-Ray Imaging Detector (GRID) data for energies greater than 100 MeV. For the first AGILE catalog, we adopted a conservative analysis, with a high-quality event filter optimized to select gamma-ray events within the central zone of the instrument field of view (radius of 40 degrees). This is a significance-limited (4 sigma) catalog, and it is not a complete flux-limited sample due to the non-uniform first-year AGILE sky coverage. The catalog includes 47 sources, 21 of which are associated with confirmed or candidate pulsars, 13 with blazars (7 FSRQ, 4 BL Lacs, 2 unknown type), 2 with HMXRBs, 2 with SNRs, 1 with a colliding-wind binary system, and 8 with unidentified sources.
  •  
2.
  • Battistoni, G., et al. (författare)
  • The FLUKA code and its use in hadron therapy
  • 2008
  • Ingår i: Nuovo Cimento della Societa Italiana di Fisica C. - Italian Physical Society. - 1124-1896. ; 31:1, s. 69-75
  • Tidskriftsartikel (refereegranskat)abstract
    • FLUKA is a multipurpose Monte Carto code describing transport and interaction with matter of a, large variety of particles over a wide energy range ill complex geometries. FLUKA is successfully applied ill several fields, including, but not only particle physics, cosmic-ray physics, dosimetry, radioprotection, hadron therapy. space radiation, accelerator design and neutronics. Here we briefly review recent model developments and provide examples of applications to hadron therapy, including calculation of physical and biological dose for comparison with analytical treatment planning engines as well as beta(+)-activation for therapy monitoring by means of positron emission tomography.
  •  
3.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy