Validity, reliability, and feasibility of durometer measurements of scleroderma skin disease in a multicenter treatment trial

Merkel, Peter A (författare)
Silliman, Nancy P (författare)
Denton, Christopher P (författare)
visa fler...
Furst, Daniel E (författare)
Khanna, Dinesh (författare)
Emery, Paul (författare)
Hsu, Vivien M (författare)
Streisand, James B (författare)
Polisson, Richard P (författare)
Åkesson, Anita (författare)
Lund University,Lunds universitet,Reumatologi och molekylär skelettbiologi,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Rheumatology,Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Coppock, John (författare)
van den Hoogen, Frank (författare)
Herrick, Ariane (författare)
Mayes, Maureen D (författare)
Veale, Douglas (författare)
Seibold, James R (författare)
Black, Carol M (författare)
Korn, Joseph H (författare)
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: Arthritis and Rheumatism. - : Wiley. - 1529-0131 .- 0004-3591. ; 59:5, s. 699-705
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. To determine the validity, reliability, and feasibility of durometer measurements of skin hardness as an outcome measure in clinical trials of scleroderma. Methods. Skin hardness was measured during a multicenter treatment trial for scleroderma using handheld digital durometers with a continuous scale. Skin thickness was measured by modified Rodnan skin score (MRSS). Other outcome data collected included the Scleroderma Health Assessment Questionnaire. In a reliability exercise in advance of the trial, 9 investigators examined the same 5 scleroderma patients by MRSS and durometry. Results. Forty-three patients with early diffuse cutaneous systemic sclerosis were studied at 11 international centers (mean age 49 years [range 24-76], median disease duration 6.4 months [range 0.3-23], and median baseline MRSS 22 [range 11-38]). The reliability of durometer measurements was excellent, with high interobserver intraclass correlation coefficients (ICCs) (0.82-0.92), and each result was greater than the corresponding skin site ICCs for MRSS (0.54-0.85). Baseline durometer scores correlated well with MRSS (r = 0.69, P < 0.0001), patient self-assessments of skin disease (r = 0.69, P < 0.0001), and Health Assessment Questionnaire (HAQ) disability scores (r = 0.34, P = 0.03). Change in durometer scores correlated with change in MRSS (r = 0.70, P < 0.0001.), change in patient self-assessments of skin disease (r = 0.52, P = 0.003), and change in HAQ disability scores (r = 0.42, P = 0.017). The effect size was greater for durometry than for MRSS or patient self-assessment. Conclusion. Durometer measurements of skin hardness in patients with scleroderma are reliable, simple, accurate, demonstrate good sensitivity to change compared with traditional skin scoring, and reflect patients' self-assessments of their disease. Durometer measurements are valid, objective, and scalable, and should be considered for use as a complementary outcome measure to skin scoring in clinical trials of scleroderma.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy