SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Meher R.) "

Sökning: WFRF:(Meher R.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jang, Seon-Kyeong, et al. (författare)
  • Rare genetic variants explain missing heritability in smoking.
  • 2022
  • Ingår i: Nature human behaviour. - : Springer Science and Business Media LLC. - 2397-3374. ; 6:11, s. 1577-1586
  • Tidskriftsartikel (refereegranskat)abstract
    • Common genetic variants explain less variation in complex phenotypes than inferred from family-based studies, and there is a debate on the source of this 'missing heritability'. We investigated the contribution of rare genetic variants to tobacco use with whole-genome sequences from up to 26,257 unrelated individuals of European ancestries and 11,743 individuals of African ancestries. Across four smoking traits, single-nucleotide-polymorphism-based heritability ([Formula: see text]) was estimated from 0.13 to 0.28 (s.e., 0.10-0.13) in European ancestries, with 35-74% of it attributable to rare variants with minor allele frequencies between 0.01% and 1%. These heritability estimates are 1.5-4 times higher than past estimates based on common variants alone and accounted for 60% to 100% of our pedigree-based estimates of narrow-sense heritability ([Formula: see text], 0.18-0.34). In the African ancestry samples, [Formula: see text] was estimated from 0.03 to 0.33 (s.e., 0.09-0.14) across the four smoking traits. These results suggest that rare variants are important contributors to the heritability of smoking.
  •  
2.
  • Berg, Johanna, et al. (författare)
  • Perceived usefulness of trauma audit filters in urban India: a mixed-methods multicentre Delphi study comparing filters from the WHO and low and middle-income countries
  • 2022
  • Ingår i: Bmj Open. - : BMJ. - 2044-6055. ; 12:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To compare experts' perceived usefulness of audit filters from Ghana, Cameroon, WHO and those locally developed; generate context-appropriate audit filters for trauma care in selected hospitals in urban India; and explore characteristics of audit filters that correlate to perceived usefulness. Design A mixed-methods approach using a multicentre online Delphi technique. Setting Two large tertiary hospitals in urban India. Methods Filters were rated on a scale from 1 to 10 in terms of perceived usefulness, with the option to add new filters and comments. The filters were categorised into three groups depending on their origin: low and middle-income countries (LMIC), WHO and New (locally developed), and their scores compared. Significance was determined using Kruskal-Wallis test followed by Wilcoxon rank-sum test. We performed a content analysis of the comments. Results 26 predefined and 15 new filter suggestions were evaluated. The filters had high usefulness scores (mean overall score 9.01 of 10), with the LMIC filters having significantly higher scores compared with those from WHO and those newly added. Three themes were identified in the content analysis relating to medical relevance, feasibility and specificity. Conclusions Audit filters from other LMICs were deemed highly useful in the urban India context. This may indicate that the transferability of defined trauma audit filters between similar contexts is high and that these can provide a starting point when implemented as part of trauma quality improvement programmes in low-resource settings.
  •  
3.
  • Lindner, Thomas, et al. (författare)
  • Current state and guidance on arterial spin labeling perfusion MRI in clinical neuroimaging.
  • 2023
  • Ingår i: Magnetic Resonance in Medicine. - : John Wiley & Sons. - 0740-3194 .- 1522-2594. ; 89:5, s. 2024-2047
  • Tidskriftsartikel (refereegranskat)abstract
    • This article focuses on clinical applications of arterial spin labeling (ASL) and is part of a wider effort from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group to update and expand on the recommendations provided in the 2015 ASL consensus paper. Although the 2015 consensus paper provided general guidelines for clinical applications of ASL MRI, there was a lack of guidance on disease-specific parameters. Since that time, the clinical availability and clinical demand for ASL MRI has increased. This position paper provides guidance on using ASL in specific clinical scenarios, including acute ischemic stroke and steno-occlusive disease, arteriovenous malformations and fistulas, brain tumors, neurodegenerative disease, seizures/epilepsy, and pediatric neuroradiology applications, focusing on disease-specific considerations for sequence optimization and interpretation. We present several neuroradiological applications in which ASL provides unique information essential for making the diagnosis. This guidance is intended for anyone interested in using ASL in a routine clinical setting (i.e., on a single-subject basis rather than in cohort studies) building on the previous ASL consensus review.
  •  
4.
  • Barquinero, J-F., et al. (författare)
  • RENEB Inter-Laboratory Comparison 2021 : The FISH-Based Translocation Assay
  • 2023
  • Ingår i: Radiation Research. - 0033-7587 .- 1938-5404. ; 199:6, s. 583-590
  • Tidskriftsartikel (refereegranskat)abstract
    • Translocation analysis using fluorescence in situ hybridization (FISH) is the method of choice for dose assessment in case of chronic or past exposures to ionizing radiation. Although it is a widespread technique, unlike dicentrics, the number of FISH-based inter-laboratory comparisons is small. For this reason, although the current Running the European Network of Biological and Physical retrospective Dosimetry (RENEB) inter-laboratory comparison 2021 was designed as a fast response to a real emergency scenario, it was considered a good opportunity to perform an inter-laboratory comparison using the FISH technique to gain further experience. The Bundeswehr Institute of Radiobiology provided peripheral blood samples from one healthy human volunteer. Three test samples were irradiated with blinded doses of 0, 1.2, and 3.5 Gy, respectively. Samples were then sent to the seven participating laboratories. The FISH technique was applied according to the standard procedure of each laboratory. Both, the frequency of translocations and the estimated dose for each sample were sent to the coordinator using a special scoring sheet for FISH. All participants sent their results in due time. However, although it was initially requested to send the results based on the full analysis, evaluating 500 equivalent cells, most laboratories only sent the results based on triage, with a smaller number of analyzed cells. In the triage analysis, there was great heterogeneity in the number of equivalent cells scored. On the contrary, for the full analysis, this number was more homogeneous. For all three samples, one laboratory showed outlier yields compared to the other laboratories. Excluding these results, in the triage analysis, the frequency of translocations in sample no. 1 ranged from 0 to 0.013 translocations per cell, and for samples no. 2 and no. 3 the genomic mean frequency were 0.27 +/- 0.03 and 1.47 +/- 0.14, with a coefficient of variation of 0.29 and 0.23 respectively. Considering only results obtained in the triage analysis for sample no. 1, all laboratories, except one, classified this sample as the non-irradiated one. For sample no. 2, excluding the outlier value, the mean reported dose was 1.74 +/- 0.16 Gy indicating a mean deviation of about 0.5 Gy to the delivered dose of 1.2 Gy. For sample no. 3 the mean dose estimated was 4.21 +/- 0.21 Gy indicating a mean deviation of about 0.7 Gy to the delivered dose of 3.5 Gy. In the frame of RENEB, this is the second FISH-based inter-laboratory comparison. The whole exercise was planned as a response to an emergency, therefore, a triage analysis was requested for all the biomarkers except for FISH. Although a full analysis was initially requested for FISH, most of the laboratories reported only a triage-based result. The main reason is that it was not clearly stated what was required before starting the exercise. Results show that most of the laboratories successfully discriminated unexposed and irradiated samples from each other without any overlap. A good agreement in the observed frequencies of translocations was observed but there was a tendency to overestimate the delivered doses. Efforts to improve the harmonization of this technique and subsequent exercises to elucidate the reason for this trend should be promoted. 
  •  
5.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy