SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Meng S) srt2:(2000-2004)"

Sökning: WFRF:(Meng S) > (2000-2004)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Fu, Q. X., et al. (författare)
  • Intermediate temperature fuel cells based on doped ceria-LiCl-SrCl2 composite electrolyte
  • 2002
  • Ingår i: Journal of Power Sources. - 0378-7753 .- 1873-2755. ; 104:1, s. 73-78
  • Tidskriftsartikel (refereegranskat)abstract
    • A new type of oxide-salt composite electrolyte, gadolinium-doped ceria (GDC)-LiCl-SrCl2, was developed and demonstrated its promising use for intermediate temperature (400-700 degreesC) fuel cells (ITFCs). The dc electrical conductivity of this composite electrolyte (0.09-0.13 S cm(-1) at 500-650 degreesC) was 3-10 times higher than that of the pure GDC electrolyte, indicating remarkable proton or oxygen ion conduction existing in the LiCl-SrCl2 chloride salts or at the interface between GDC and the chloride salts. Using this composite electrolyte, peak power densities of 260 and 510 mW cm(-2), with current densities of 650 and 1250 mA cm(-2) were achieved at 550 and 625 degreesC, respectively. This makes the new material a good candidate electrolyte for future low-cost ITFCs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy