SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Michel S) srt2:(2005-2009)"

Sökning: WFRF:(Michel S) > (2005-2009)

  • Resultat 1-10 av 31
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Aguilar, J A, et al. (författare)
  • Transmission of light in deep sea water at the site of the ANTARES neutrino telescope
  • 2005
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 23:1, s. 131-155
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length;,ab, and an effective scattering length lambda(sct)(eff). The values for blue (UV) light are found to be lambda(abs) similar or equal to 60(26) m, lambda(sct)(eff similar or equal to) 265(122) m, with significant (similar to15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented. (C) 2004 Elsevier B.V. All rights reserved.
  •  
3.
  • Klionsky, Daniel J., et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring autophagy in higher eukaryotes
  • 2008
  • Ingår i: Autophagy. - : Landes Bioscience. - 1554-8627 .- 1554-8635. ; 4:2, s. 151-175
  • Forskningsöversikt (refereegranskat)abstract
    • Research in autophagy continues to accelerate,1 and as a result many new scientists are entering the field. Accordingly, it is important to establish a standard set of criteria for monitoring macroautophagy in different organisms. Recent reviews have described the range of assays that have been used for this purpose.2,3 There are many useful and convenient methods that can be used to monitor macroautophagy in yeast, but relatively few in other model systems, and there is much confusion regarding acceptable methods to measure macroautophagy in higher eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers of autophagosomes versus those that measure flux through the autophagy pathway; thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from fully functional autophagy that includes delivery to, and degradation within, lysosomes (in most higher eukaryotes) or the vacuole (in plants and fungi). Here, we present a set of guidelines for the selection and interpretation of the methods that can be used by investigators who are attempting to examine macroautophagy and related processes, as well as by reviewers who need to provide realistic and reasonable critiques of papers that investigate these processes. This set of guidelines is not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to verify an autophagic response.
  •  
4.
  • Ahrens, J, et al. (författare)
  • Intermediate resonance excitation in the gamma p -> p pi(0)pi(0) reaction
  • 2005
  • Ingår i: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 624:3-4, s. 173-180
  • Tidskriftsartikel (refereegranskat)abstract
    • The helicity dependence of the total cross section for the (gamma) over right arrow(p) over right arrow -> p pi(0)pi(0) reaction has been measured for the first time at incident photon energies from 400 to 800 MeV. The measurement, performed at the tagged photon beam facility of the MAMI accelerator in Mainz, used the large acceptance detector DAPHNE and a longitudinally polarized frozen-spin target. This channel is found to be excited predominantly when the photon and proton have a parallel spin orientation, most likely due to the intermediate production of the D-13(1520) resonance. However, the contribution of the antiparallel spin configuration, arising from other reaction mechanisms, is also not negligible. This result gives important new information to resolve the existing model discrepancies in the identification of the nucleon resonances contributing to this channel.
  •  
5.
  • Dutz, H, et al. (författare)
  • Measurement of helicity-dependent photoabsorption cross sections on the neutron from 815 to 1825 MeV
  • 2005
  • Ingår i: Physical Review Letters. - 1079-7114. ; 94
  • Tidskriftsartikel (refereegranskat)abstract
    • Helicity-dependent total photoabsorption cross sections on the deuteron have been measured for the first time at ELSA (Bonn) in the photon energy range from 815 to 1825 MeV. Circularly polarized tagged photons impinging on a longitudinally polarized LiD target have been used together with a highly efficient 4 pi detector system. The data around 1 GeV are not compatible with predictions from existing multipole analyses. From the measured energy range an experimental contribution to the GDH integral on the neutron of [33.9 +/- 5.5(stat)+/- 4.5(syst)] mu b is extracted.
  •  
6.
  •  
7.
  • Pham, M. K., et al. (författare)
  • A new Certified Reference Material for radionuclides in Irish sea sediment (IAEA-385)
  • 2008
  • Ingår i: APPLIED RADIATION AND ISOTOPES. - : Elsevier BV. - 1872-9800 .- 0969-8043. ; 66:11, s. 1711-1717
  • Konferensbidrag (refereegranskat)abstract
    • A new Certified Reference Material (CRM) for radionuclides in sediment (IAEA-385) is described and the results of the certification process are presented. Eleven radionuclides (K-40, Cs-137, Ra-226, Ra-228, Th-230, Th-232, U-234, U-238, Pu-238, Pu239+240 and Am-241) have been certified and information mass activities with 95% confidence intervals are given for seven other radionuclides (Sr-90, Pb-210(Po-210), U-235, Pu-239, Pu-240 and Pu-241). Results for less frequently reported radionuclides (Co-60, Tc-99, Cs-134, Eu-155, Ra-224 and Np-239) and information on some activity and mass ratios are also reported. The CRM can be used for quality assurance/quality control of the analysis of radionuclides in sediment samples, for the development and validation of analytical methods and for training purposes. (C) 2008 IAEA. Published by Elsevier Ltd. All rights reserved.
  •  
8.
  • de Jong, Michel P, et al. (författare)
  • Femtosecond charge transfer in assemblies of discotic liquid crystals
  • 2008
  • Ingår i: The Journal of Physical Chemistry C. - : American Chemical Society (ACS). - 1932-7447 .- 1932-7455. ; 112:40, s. 15784-15790
  • Tidskriftsartikel (refereegranskat)abstract
    • The electronic coupling strength within columns of discotic liquid crystals is investigated using core-level resonant photoemission spectroscopy. Coexisting well-ordered and disordered regions are identified in thin films of tetra-alkoxy-substituted phthalocyanines with the aid of near edge X-ray absorption fine structure and photoelectron spectroscopies. These different regions are used to derive a lower limit for the intermolecular charge transfer bandwidth within the framework of the core-hole clock principle. We find average charge transfer times on the order of a few femtoseconds, that is, significantly faster than the C(ls) core-hole lifetime, which indicates a surprisingly strong electronic coupling between the phthalocyanine units as compared to what is expected from the charge transport characteristics of this material. © 2008 American Chemical Society.
  •  
9.
  • Maisel, Alan, et al. (författare)
  • State of the art : Using natriuretic peptide levels in clinical practice
  • 2008
  • Ingår i: European Journal of Heart Failure. - : Wiley. - 1388-9842 .- 1879-0844. ; 10:9, s. 824-839
  • Tidskriftsartikel (refereegranskat)abstract
    • Natriuretic peptide (NP) levels (B-type natriuretic peptide (BNP) and N-terminal proBNP) are now widely used in clinical practice and cardiovascular research throughout the world and have been incorporated into most national and international cardiovascular guidelines for heart failure. The role of NP levels in state-of-the-art clinical practice is evolving rapidly. This paper reviews and highlights ten key messages to clinicians:•NP levels are quantitative plasma biomarkers of heart failure (HF).•NP levels are accurate in the diagnosis of HF.•NP levels may help risk stratify emergency department (ED) patients with regard to the need for hospital admission or direct ED discharge.•NP levels help improve patient management and reduce total treatment costs in patients with acute dyspnoea.•NP levels at the time of admission are powerful predictors of outcome in predicting death and re-hospitalisation in HF patients.•NP levels at discharge aid in risk stratification of the HF patient.•NP-guided therapy may improve morbidity and/or mortality in chronic HF.•The combination of NP levels together with symptoms, signs and weight gain assists in the assessment of clinical decompensation in HF.•NP levels can accelerate accurate diagnosis of heart failure presenting in primary care.•NP levels may be helpful to screen for asymptomatic left ventricular dysfunction in high-risk patients.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 31

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy