SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mirzai Maral) srt2:(2021)"

Sökning: WFRF:(Mirzai Maral) > (2021)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Meltzer, Carin, et al. (författare)
  • Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
  • 2021
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 62:3, s. 348-359
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Digital tomosynthesis (DTS) might be a low-dose/low-cost alternative to computed tomography (CT). Purpose To investigate DTS relative to CT for surveillance of incidental, solid pulmonary nodules. Material and Methods Recruited from a population study, 106 participants with indeterminate solid pulmonary nodules on CT underwent surveillance with concurrently performed CT and DTS. Nodule size on DTS was assessed by manual diameter measurements and semi-automatic nodule segmentations were independently performed on CT. Measurement agreement was analyzed according to Bland-Altman with 95% limits of agreement (LoA). Detection of nodule volume change > 25% by DTS in comparison to CT was evaluated with receiver operating characteristics (ROC). Results A total of 81 nodules (76%) were assessed as measurable on DTS by two independent observers. Inter- and intra-observer LoA regarding change in average diameter were +/- 2 mm. Calculation of relative volume change on DTS resulted in wide inter- and intra-observer LoA in the order of +/- 100% and +/- 50%. Comparing relative volume change between DTS and CT resulted in LoA of -58% to 67%. The area under the ROC curve regarding the ability of DTS to detect volumetric changes > 25% on CT was 0.58 (95% confidence interval [CI] = 0.40-0.76) and 0.50 (95% CI = 0.35-0.66) for the two observers. Conclusion The results of the present study show that measurement variability limits the agreement between DTS and CT regarding nodule size change for small solid nodules.
  •  
2.
  • Mirzai, Maral, et al. (författare)
  • The Effect of Dose Reduction on Overall Image Quality in Clinical Chest Tomosynthesis
  • 2021
  • Ingår i: Academic Radiology. - : Elsevier BV. - 1076-6332. ; 28:10, s. 289-296
  • Tidskriftsartikel (refereegranskat)abstract
    • Rationale and Objectives: To evaluate the effect of reduction in effective dose on the reproduction of anatomical structures in chest tomosynthesis (CTS). Materials and Methods: Twenty-four CTS examinations acquired at exposure settings resulting in an effective dose of 0.12 mSv for an average sized patient were included in the study. The examinations underwent simulated dose reduction to dose levels corresponding to 32%, 50%, and 70% of the original dose using a previously described and validated method. The image quality was evaluated by five thoracic radiologists who rated the fulfillment of specified image quality criteria in a visual grading study. The ratings for each image quality criterion in the dose-reduced images were compared to the corresponding ratings for the full-dose examinations using visual grading characteristics (VGC) analysis. The area under the resulting VGC curve (AUCVGC) provides a measure of the difference between the ratings, where an AUCVGC of 0.5 indicates no difference. Results: The dose reductions resulted in inferior reproduction of structures compared to the original dose level (AUCVGC <0.5). Structures in the central region of the lung obtained the lowest AUCVGC for each dose level whereas the reproduction of structures in the parenchyma was least affected by the dose reduction. Conclusion: Although previous studies have shown that dose reduction in CTS is possible without affecting the performance of certain clinical tasks, the reproduction of normal anatomical structures is significantly degraded even at small reductions. It is therefore important to consider the clinical purpose of the CTS examinations before deciding on a permanent dose reduction. © 2020 The Association of University Radiologists
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy