SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Moberg T) srt2:(2020-2024)"

Sökning: WFRF:(Moberg T) > (2020-2024)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Gadelshin, V. M., et al. (författare)
  • First laser ions at the CERN-MEDICIS facility
  • 2020
  • Ingår i: Hyperfine Interactions. - : Springer Science and Business Media LLC. - 0304-3843 .- 1572-9540. ; 241:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The CERN-MEDICIS facility aims to produce emerging medical radionuclides for the theranostics approach in nuclear medicine with mass separation of ion beams. To enhance the radioisotope yield and purity of collected samples, the resonance ionization laser ion source MELISSA was constructed, and provided the first laser ions at the facility in 2019. Several operational tests were accomplished to investigate its performance in preparation for the upcoming production of terbium radioisotopes, which are of particular interest for medical applications. © 2020, The Author(s).
  •  
4.
  • Visanuyanont, T., et al. (författare)
  • AUTOMATED QC FOR INTERVENTIONAL SYSTEMS AND MAMMOGRAPHY SYSTEMS
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 399-406
  • Tidskriftsartikel (refereegranskat)abstract
    • Quality control (QC) of X-ray equipment is an important task for patient safety. Periodic QC should not take long to perform, especially in a stressful clinical environment where downtime should be minimised. DOSESTAT-QC (R) is a new quick QC software with automatic image analysis that has been developed into a quality-assured and user-friendly tool for daily use. Trained X-ray personnel can easily perform the QC with selected image phantoms and immediately approve the results onsite before the equipment is used clinically. Image analysis includes visibility of contrast detail groups, homogeneity, signal-to-noise ratio and contrast-to-noise ratio. In the event of unapproved QC, a message is automatically sent to medical physicists and/or medical engineers. The results are stored over time and are available for trend analysis. The present paper describes the DOSESTAT-QC (R) software and its application in QC of interventional X-ray systems and mammography systems.
  •  
5.
  • Ballof, J., et al. (författare)
  • A concept for the extraction of the most refractory elements at CERN-ISOLDE as carbonyl complex ions
  • 2022
  • Ingår i: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-6001 .- 1434-601X. ; 58:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We introduce a novel thick-target concept tailored to the extraction of refractory 4d and 5d transition metal radionuclides of molybdenum, technetium, ruthenium and tungsten for radioactive ion beam production. Despite the more than 60-year old history of thick-target ISOL mass-separation facilities like ISOLDE, the extraction of these most refractory elements as radioactive ion beam has so far not been successful. In ordinary thick ISOL targets, their radioisotopes produced in the target are stopped within the condensed target material. Here, we present a concept which overcomes limitations associated with this method. We exploit the recoil momentum of nuclear reaction products for their release from the solid target material. They are thermalized in a carbon monoxide-containing atmosphere, in which volatile carbonyl complexes form readily at ambient temperature and pressure. This compound serves as volatile carrier for transport to the ion source. Excess carbon monoxide is removed by cryogenic gas separation to enable low pressures in the source region, in which the species are ionized and hence made available for radioactive ion beam formation. The setup is operated in batch mode. Initially, we investigate the feasibility of the approach with isotopes of more than 35s half-life. At the cost of reduced efficiency, the concept could also be applied to isotopes with half-lives of at least one to 10s. We report parameter studies of the key processes of the method, which validate this concept and which define the parameters for the setup. This would allow for the first time the extraction of radioactive molybdenum, tungsten and several other transition metals at thick-target ISOL facilities.
  •  
6.
  • Bitar, C., et al. (författare)
  • 11-Year outcomes in patients with metal-on-metal ASR hip arthroplasty
  • 2022
  • Ingår i: Journal of Orthopaedics. - : Elsevier BV. - 0972-978X .- 2589-9082. ; 32, s. 98-103
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: We analysed the long-term revision rate, clinical outcomes and metal ion concentrations in blood over time in patients who had undergone metal-on metal Articular Surface Replacement (ASR) hip arthroplasty. Methods: A total of 38 patients (43 hips) were included: 24 patients (28 hips) underwent large-head total hip arthroplasty (XL THA), and 14 patients (15 hips) underwent hip resurfacing arthroplasty (HRA). The median follow-up time was 11 (range 7-12) years. Results: None of 15 HRA implants were revised. Nine of 28 XL THA implants (32%) in 8 patients were revised. The Co ion levels significantly increased in the XL THA group (p=0.009) over a median time period of 84 (25-97) months. Conclusion: The levels of Co ions in blood were higher in the patients who had undergone XL THA and increased significantly over time.
  •  
7.
  • FitzGerald, Edward A., et al. (författare)
  • Multiplexed experimental strategies for fragment library screening using SPR biosensors
  • 2020
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Surface plasmon resonance biosensor technology (SPR) is ideally suited for fragment-based lead discovery. However, generally suitable experimental procedures or detailed protocols are lacking, especially for structurally or physico-chemically challenging targets or when tool compounds are lacking. Success depends on accounting for the features of both the target and the chemical library, purposely designing screening experiments for identification and validation of hits with desired specificity and mode-of-action, and availability of orthogonal methods capable of confirming fragment hits. By adopting a multiplexed strategy, the range of targets and libraries amenable to an SPR biosensor-based approach for identifying hits is considerably expanded. We here illustrate innovative strategies using five challenging targets and variants thereof. Two libraries of 90 and 1056 fragments were screened using two different flow-based SPR biosensor systems, allowing different experimental approaches. Practical considerations and procedures accounting for the characteristics of the proteins and libraries, and that increase robustness, sensitivity, throughput and versatility are highlighted.Competing Interest StatementAnna Moberg, Maria T. Lindgren and Claes Holmgren work for Cytiva, which produce Biacore systems.
  •  
8.
  • FitzGerald, Edward, et al. (författare)
  • Multiplexed experimental strategies for fragment library screening against challenging drug targets using SPR biosensors
  • 2024
  • Ingår i: SLAS Discovery. - : Elsevier. - 2472-5560 .- 2472-5552. ; :1, s. 40-51
  • Tidskriftsartikel (refereegranskat)abstract
    • Surface plasmon resonance (SPR) biosensor methods are ideally suited for fragment-based lead discovery.  However, generally applicable experimental procedures and detailed protocols are lacking, especially for structurally or physico-chemically challenging targets or when tool compounds are not available. Success depends on accounting for the features of both the target and the chemical library, purposely designing screening experiments for identification and validation of hits with desired specificity and mode-of-action, and availability of orthogonal methods capable of confirming fragment hits. The range of targets and libraries amenable to an SPR biosensor-based approach for identifying hits is considerably expanded by adopting multiplexed strategies, using multiple complementary surfaces or experimental conditions. Here we illustrate principles and multiplexed approaches for using flow-based SPR biosensor systems for screening fragment libraries of different sizes (90 and 1056 compounds) against a selection of challenging targets. It shows strategies for the identification of fragments interacting with 1) large and structurally dynamic targets, represented by acetyl choline binding protein (AChBP), a Cys-loop receptor ligand gated ion channel homologue, 2) targets in multi protein complexes, represented by lysine demethylase 1 and a corepressor (LSD1/CoREST), 3) structurally variable or unstable targets, represented by farnesyl pyrophosphate synthase (FPPS), 4) targets containing intrinsically disordered regions, represented by protein tyrosine phosphatase 1B  (PTP1B), and 5) aggregation-prone proteins, represented by an engineered form of human tau  (tau K18M). Practical considerations and procedures accounting for the characteristics of the proteins and libraries, and that increase robustness, sensitivity, throughput and versatility are highlighted. The study shows that the challenges for addressing these types of targets is not identification of potentially useful fragments per se, but establishing methods for their validation and evolution into leads.
  •  
9.
  • Meth, Elisa M. S., et al. (författare)
  • A weighted blanket increases pre-sleep salivary concentrations of melatonin in young, healthy adults
  • 2023
  • Ingår i: Journal of Sleep Research. - : John Wiley & Sons. - 0962-1105 .- 1365-2869. ; 32:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Weighted blankets have emerged as a potential non-pharmacological intervention to ease conditions such as insomnia and anxiety. Despite a lack of experimental evidence, these alleged effects are frequently attributed to a reduced activity of the endogenous stress systems and an increased release of hormones such as oxytocin and melatonin. Thus, the aim of the present in-laboratory crossover study (26 young and healthy participants, including 15 men and 11 women) was to investigate if using a weighted blanket (~12% of body weight) at bedtime resulted in higher salivary concentrations of melatonin and oxytocin compared with a light blanket (~2.4% of body weight). We also examined possible differences in salivary concentrations of the stress hormone cortisol, salivary alpha-amylase activity (as an indicative metric of sympathetic nervous system activity), subjective sleepiness, and sleep duration. When using a weighted blanket, the 1 hour increase of salivary melatonin from baseline (i.e., 22:00) to lights off (i.e., 23:00) was about 32% higher (p = 0.011). No other significant differences were found between the blanket conditions, including subjective sleepiness and total sleep duration. Our study is the first to suggest that using a weighted blanket may result in a more significant release of melatonin at bedtime. Future studies should investigate whether the stimulatory effect on melatonin secretion is observed on a nightly basis when frequently using a weighted blanket over weeks to months. It remains to be determined whether the observed increase in melatonin may be therapeutically relevant for the previously described effects of the weighted blanket on insomnia and anxiety.
  •  
10.
  • Ringvall-Moberg, Annie, 1988, et al. (författare)
  • Time-of-Flight study of molecular beams extracted from the ISOLDE RFQ cooler and buncher
  • 2020
  • Ingår i: Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 463, s. 522-524
  • Tidskriftsartikel (refereegranskat)abstract
    • Molecular beams injected into the ISOLDE Radio-Frequency Quadrupole cooler and buncher (RFQcb), ISCOOL, have been studied under varying conditions using a new Time-of-Flight (ToF) detector. When a beam of molecules is injected into the RFQcb and interacts with the buffer gas, collisional dissociation processes may occur. In this study, two different beams of molecules, CO+ and Ni-2(+), were separately injected into ISCOOL, and two different buffer gases (pure helium or a 90:10 mixture of helium and neon) were used. The radio-frequency of the RFQcb was varied as the molecules, along with the fragments from the dissociation processes, were extracted from ISCOOL and studied using the new Time-of-Flight detector. The main finding of this work is that the rates for molecular dissociation within ISCOOL were very small for both CO+ and Ni-2(+), with the largest rates found for CO+.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy