SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Moll V) srt2:(2005-2009)"

Sökning: WFRF:(Moll V) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bruzzi, M, et al. (författare)
  • Radiation-hard semiconductor detectors for SuperLHC
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 541:1-2, s. 189-201
  • Tidskriftsartikel (refereegranskat)abstract
    • An option of increasing the luminosity of the Large Hadron Collider (LHC) at CERN to 1035 cm-2 s-1 has been envisaged to extend the physics reach of the machine. An efficient tracking down to a few centimetres from the interaction point will be required to exploit the physics potential of the upgraded LHC. As a consequence, the semiconductor detectors close to the interaction region will receive severe doses of fast hadron irradiation and the inner tracker detectors will need to survive fast hadron fluences of up to above 1016cm-2. The CERN-RD50 project "Development of Radiation Hard Semiconductor Devices for Very High Luminosity Colliders" has been established in 2002 to explore detector materials and technologies that will allow to operate devices up to, or beyond, this limit. The strategies followed by RD50 to enhance the radiation tolerance include the development of new or defect engineered detector materials (SiC, GaN, Czochralski and epitaxial silicon, oxygen enriched Float Zone silicon), the improvement of present detector designs and the understanding of the microscopic defects causing the degradation of the irradiated detectors. The latest advancements within the RD50 collaboration on radiation hard semiconductor detectors will be reviewed and discussed in this work.
  •  
2.
  • Galluzzi, L, et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring cell death in higher eukaryotes.
  • 2009
  • Ingår i: Cell death and differentiation. - : Springer Science and Business Media LLC. - 1476-5403 .- 1350-9047. ; 16:8, s. 1093-107
  • Forskningsöversikt (refereegranskat)abstract
    • Cell death is essential for a plethora of physiological processes, and its deregulation characterizes numerous human diseases. Thus, the in-depth investigation of cell death and its mechanisms constitutes a formidable challenge for fundamental and applied biomedical research, and has tremendous implications for the development of novel therapeutic strategies. It is, therefore, of utmost importance to standardize the experimental procedures that identify dying and dead cells in cell cultures and/or in tissues, from model organisms and/or humans, in healthy and/or pathological scenarios. Thus far, dozens of methods have been proposed to quantify cell death-related parameters. However, no guidelines exist regarding their use and interpretation, and nobody has thoroughly annotated the experimental settings for which each of these techniques is most appropriate. Here, we provide a nonexhaustive comparison of methods to detect cell death with apoptotic or nonapoptotic morphologies, their advantages and pitfalls. These guidelines are intended for investigators who study cell death, as well as for reviewers who need to constructively critique scientific reports that deal with cellular demise. Given the difficulties in determining the exact number of cells that have passed the point-of-no-return of the signaling cascades leading to cell death, we emphasize the importance of performing multiple, methodologically unrelated assays to quantify dying and dead cells.
  •  
3.
  • Boisvert, V, et al. (författare)
  • Characterization of oxygen dimer-enriched silicon detectors
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 552:1-2, s. 49-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Various types of silicon material and silicon p(+)n diodes have been treated to increase the concentration of the oxygen dimer (02) defect. This was done by exposing the bulk material and the diodes to 6 MeV electrons at a temperature of about 350 degrees C. FTIR spectroscopy has been performed on the processed material confirming the formation of oxygen dimer defects in Czochralski silicon pieces. We also show results from TSC characterization on processed diodes. Finally, we investigated the influence of the dimer enrichment process on the depletion voltage of silicon diodes and performed 24 GeV/c proton irradiations to study the evolution of the macroscopic diode characteristics as a function of fluence.
  •  
4.
  • Norkus, A, et al. (författare)
  • Use of a hydrocapillary dressing in the management of highly exuding ulcers; a comparative study
  • 2005
  • Ingår i: Journal of Wound Care. - 0969-0700. ; 14:9, s. 129-432
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To evaluate the safety and performance of Alione Hydrocapillary dressing (Coloplast A/S) in the management of highly exuding chronic venous leg ulcers and compare it with two hydropolymer dressings, Tielle and Tielle Plus (Johnson & Johnson). Method: A comparative clinical trial was conducted on 97 patients with an ankle brachial pressure index ?0.8 and a highly exuding leg ulcer. Ulcer duration was at least four weeks. Treatment continued until healing or for a maximum of 12 months. Results: There was no statistically significant difference in healing time or wound area reduction between the two treatment protocols. The test dressing (Alione Hydrocapillary) had better absorption capacity and was more comfortable for the patients than the comparator dressings (Tielle/Tielle Plus) and adhered less to the wound bed. Also, more patients preferred the test dressing to their previous treatment. Although severe leakage and maceration were observed more frequently in the comparator group compared with the test group, this was not statistically significant. Conclusion: Both treatment protocols were safe and effective in treating highly exuding chronic venous leg ulcers. The test dressing performed as well as or better than the comparator dressings for all study parameters and more patients preferred the test dressing to their previous dressing compared with the comparator dressings.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy