1.
  • Mondlane, Gracinda, 1987- (författare)
  • Comparative study of Radiation Therapy of Targets in the Upper Abdomen with Photon- or Scanned Proton-beams
  • 2017
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Recently, there has been an increase in the number of proton beam therapy (PBT) centers operating worldwide. For certain cases, proton beams have been shown to provide dosimetric and radiobiological advantages when used for cancer treatment, compared to the regular photon-beam based treatments. Under ideal circumstances, the dose given to the tissues surrounding a target can be reduced with PBT. The risk for side effects following treatment is then expected to decrease. Until present, mainly stationary targets, e.g. targets in the brain, have been treated with PBT. There is currently a growing interest to treat also target volumes in other parts of the body with PBT. However, there are sources of uncertainties, which must be more carefully considered when PBT is used, especially for PBT carried out with scanned proton beams. PBT is more sensitive to anatomical changes, e.g. organ motion or a variable gas content in the intestines, which requires that special precautions are taken prior to treating new tumour sites. In photon beam radiotherapy (RT) of moving targets, the main consequence of organ motion is the loss of sharpness of the dose gradients (dose smearing). When scanned proton beams are used, dose deformation caused by the fluctuations in the proton beam range, due to varying tissue heterogeneities (e.g., the ribs moving in and out of the beam path) and the so-called interplay effect, can be expected to impact the dose distributions in addition to the dose smearing. The dosimetric uncertainties, if not accounted for, may cause the planned and accurately calculated dose distribution to be distorted, compromising the main goal of RT of achieving the maximal local disease control while accepting certain risks for normal tissue complications.Currently there is a lack of clinical follow-up data regarding the outcome of PBT for different tumour sites, in particular for extra-cranial tumour sites in moving organs. On the other hand, the use of photon beams for this kind of cancer treatment is well-stablished. A treatment planning comparison between RT carried out with photons and with protons may provide guidelines for when PBT could be more suitable. New clinical applications of particle beams in cancer therapy can also be transferred from photon-beam treatments, for which there is a vast clinical experience. The evaluation of the different uncertainties influencing RT of different tumour sites carried out with photon- and with proton-beams, will hopefully create an understanding for the feasibility of treating cancers with scanned proton beams instead of photon beams. The comparison of two distinct RT modalities is normally performed by studying the dosimetric values obtained from the dose volume histograms (DVH). However, in dosimetric evaluations, the outcome of the treatments in terms of local disease control and healthy tissue toxicity are not estimated. In this regard, radiobiological models can be an indispensable tool for the prediction of the outcome of cancer treatments performed with different types of ionising radiation. In this thesis, different factors that should be taken into consideration in PBT, for treatments influenced by organ motion and density heterogeneities, were studied and their importance quantified.This thesis consists of three published articles (Articles I, II and III). In these reports, the dosimetric and biological evaluations of photon-beam and scanned proton-beam RT were performed and the results obtained were compared. The studies were made for two tumour sites influenced by organ motion and density changes, gastric cancer (GC) and liver metastases. For the GC cases, the impact of changes in tissue density, resulting from variable gas content (which can be observed inter-fractionally), was also studied. In this thesis, both conventional fractionations (implemented in the planning for GC treatments) and hypofractionated regimens (implemented in the planning for the liver metastases cases) were considered. In this work, it was found that proton therapy provided the possibility to reduce the irradiations of the normal tissue located near the target volumes, compared to photon beam RT. However, the effects of density changes were found to be more pronounced in the plans for PBT. Furthermore, with proton beams, the reduction of the integral dose given to the OARs resulted in reduced risks of treatment-induced secondary malignancies.
  •  
2.
  • Mondlane, Gracinda, 1987-, et al. (författare)
  • Comparative study of the calculated risk of radiation-induced cancer after photon- and proton-beam based radiosurgery of liver metastases
  • 2017
  • Ingår i: Physica medica (Testo stampato). - : Elsevier BV. - 1120-1797 .- 1724-191X. ; 42, s. 263-270
  • Tidskriftsartikel (refereegranskat)abstract
    • IntroductionThe potential of proton therapy to improve the sparing of the healthy tissue has been demonstrated in several studies. However, even small doses delivered to the organs at risk (OAR) may induce long-term detriments after radiotherapy. In this study, we investigated the possibility to reduce the risk of radiation-induced secondary cancers with intensity modulated proton therapy (IMPT), when used for radiosurgery of liver metastases.Material and methodsTen patients, previously treated for liver metastases with photon-beam based stereotactic body radiation therapy (SBRT) were retrospectively planned for radiosurgery with IMPT. A treatment plan comparison was then performed in terms of calculated risk of radiation-induced secondary cancer. The risks were estimated using two distinct models (Dasu et al., 2005; Schneider et al., 2005, 2009). The plans were compared pairwise with a two-sided Wilcoxon signed-rank test with a significance level of 0.05.ResultsReduced risks for induction of fatal and other types of cancers were estimated for the IMPT plans (p < 0.05) with the Dasu et al. model. Using the Schneider et al. model, lower risks for carcinomainduction with IMPT were estimated for the skin, lungs, healthy part of the liver, esophagus and the remaining part of the body (p < 0.05). The risk of observing sarcomas in the bone was also reduced with IMPT (p < 0.05).ConclusionThe findings of this study indicate that the risks of radiation-induced secondary cancers after radiosurgery of liver metastases may be reduced, if IMPT is used instead of photon-beam based SBRT.
  •  
3.
  • Mondlane, Gracinda, 1987-, et al. (författare)
  • Comparison of gastric-cancer radiotherapy performed with volumetric modulated arc therapy or single-field uniform-dose proton therapy
  • 2017
  • Ingår i: Acta Oncologica. - 0284-186X .- 1651-226X. ; 56:6, s. 832-838
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Proton-beam therapy of large abdominal cancers has been questioned due to the large variations in tissue density in the abdomen. The aim of this study was to evaluate the importance of these variations for the dose distributions produced in adjuvant radiotherapy of gastric cancer (GC), implemented with photon-based volumetric modulated arc therapy (VMAT) or with proton-beam single-field uniform-dose (SFUD) method. Material and methods: Eight GC patients were included in this study. For each patient, a VMAT- and an SFUD-plan were created. The prescription dose was 45 Gy (IsoE) given in 25 fractions. The plans were prepared on the original CT studies and the doses were thereafter recalculated on two modified CT studies (one with extra water filling and the other with expanded abdominal air-cavity volumes). Results: Compared to the original VMAT plans, the SFUD plans resulted in reduced median values for the V18 of the left kidney (26%), the liver mean dose (14.8 Gy (IsoE)) and the maximum dose given to the spinal cord (26.6 Gy (IsoE)). However, the PTV coverage decreased when the SFUD plans were recalculated on CT sets with extra air- (86%) and water-filling (87%). The added water filling only led to minor dosimetric changes for the OARs, but the extra air caused significant increases of the median values of V18 for the right and left kidneys (10% and 12%, respectively) and of V10 for the liver (12%). The density changes influenced the dose distributions in the VMAT plans to a minor extent. Conclusions: SFUD was found to be superior to VMAT for the plans prepared on the original CT sets. However, SFUD was inferior to VMAT for the modified CT sets.
  •  