SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Morell Arvid)
 

Sökning: WFRF:(Morell Arvid) > (2008-2009) > Quantitative renal ...

Quantitative renal cortical perfusion in human subjects with magnetic resonance imaging using iron-oxide nanoparticles: influence of T1 shortening

Morell, Arvid, 1973- (författare)
Uppsala universitet,Enheten för radiologi
Ahlström, Håkan (författare)
Uppsala universitet,Enheten för radiologi
Schoenberg, Stefan (författare)
University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine
visa fler...
Abildgaard, Andreas (författare)
Rikshospitalet University Hospital, Department of Radiology
Bock, Michael (författare)
German Cancer Research Center (DKFZ), Department of Medical Physics in Radiology
Bjørnerud, Atle (författare)
Uppsala universitet,Enheten för radiologi
visa färre...
 (creator_code:org_t)
2008-10-01
2008
Engelska.
Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 49:8, s. 955-62
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Using conventional contrast agents, the technique of quantitative perfusion by observing the transport of a bolus with magnetic resonance imaging (MRI) is limited to the brain due to extravascular leakage. PURPOSE: To perform quantitative perfusion measurements in humans with an intravascular contrast agent, and to estimate the influence of the T1 relaxivity of the contrast agent on the first-pass response. MATERIAL AND METHODS: Renal cortical perfusion was measured quantitatively in six patients with unilateral renal artery stenosis using a rapid gradient double-echo sequence in combination with an intravenous bolus injection of NC100150 Injection, an intravascular contrast agent based on iron-oxide nanoparticles. The influence of T1 relaxivity was measured by comparing perfusion results based on single- and double-echo data. RESULTS: The mean values of cortical blood flow, cortical blood volume, and mean transit time in the normal kidneys were measured to 339+/-60 ml/min/100 g, 41+/-8 ml/100 g, and 7.3+/-1.0 s, respectively, based on double-echo data. The corresponding results based on single-echo data, which are not compensated for the T1 relaxivity, were 254+/-47 ml/min/100 g, 27+/-3 ml/100 g, and 6+/-1.2 s, respectively. CONCLUSION: The use of a double-echo sequence enabled elimination of confounding T1 effects and consequent systematic underestimation of the perfusion.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Radiology
Radiologi
Radiology
Radiologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy