SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Moszynski M) srt2:(2015-2019)"

Sökning: WFRF:(Moszynski M) > (2015-2019)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jaworski, G., et al. (författare)
  • The New Neutron Multiplicity Filter NEDA and Its First Physics Campaign with AGATA
  • 2019
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 50:3, s. 585-590
  • Tidskriftsartikel (refereegranskat)abstract
    • A new neutron multiplicity filter NEDA, after a decade of design, R&D and construction, was employed in its first physics campaign with the AGATA spectrometer. Properties and performance of the array are discussed.
  •  
2.
  • Valiente-Dobon, J. J., et al. (författare)
  • NEDA-NEutron Detector Array
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 927, s. 81-86
  • Tidskriftsartikel (refereegranskat)abstract
    • The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with gamma-ray arrays, such as the tracking-array AGATA, to aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-gamma discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1 pi was realised at GANIL. This manuscript reviews the various aspects of NEDA.
  •  
3.
  • Egea Canet, F. J., et al. (författare)
  • A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1056-1062
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
  •  
4.
  • Egea Canet, F. J., et al. (författare)
  • Digital Front-End Electronics for the Neutron Detector NEDA
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1063-1069
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
  •  
5.
  • Luo, X. L., et al. (författare)
  • Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
  • 2018
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 897, s. 59-65
  • Tidskriftsartikel (refereegranskat)abstract
    • The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or gamma rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-gamma discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
  •  
6.
  • Modamio, V., et al. (författare)
  • Digital pulse-timing technique for the neutron detector array NEDA
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 775, s. 71-76
  • Tidskriftsartikel (refereegranskat)abstract
    • A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
  •  
7.
  • Swiderski, L., et al. (författare)
  • Scintillation response to gamma-rays measured at wide temperature range for Tl doped CsI with SiPM readout
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 916, s. 32-36
  • Tidskriftsartikel (refereegranskat)abstract
    • A custom design cryostat was constructed to study the temperature dependence of relative light yield and non-proportionality trends of scintillators between -182 degrees C and +152 degrees C. CsI:Tl crystal response to gamma-rays and X-rays was investigated between 14 keV and 662 keV. Scintillation light was detected by a SiPM device, which was installed on a copper frame separated from the crystal and the cooling rod to enable operating the device at room temperature. The scintillation efficiency of CsI:Tl is peaked at about room temperature. The light yield of CsI:Tl at temperature close to liquid nitrogen boiling point is reduced by a factor of 15 in comparison to room temperature conditions. The non-proportionality of CsI:Tl scintillation response is high at low temperatures and is getting more proportional with increasing temperature.
  •  
8.
  • Swiderski, L., et al. (författare)
  • Temperature Dependence of CsI:T1 Scintillation Pulse Shapes from-183 degrees C to+90 degrees C Measured with a SiPM Readout
  • 2017
  • Ingår i: 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC). - : IEEE. - 9781538622827
  • Konferensbidrag (refereegranskat)abstract
    • A custom designed cryostat was constructed to measure the response of a CsI:T1 scintillator in temperature range from -183 degrees C up to +90 degrees C. The light readout was realized using a SiPM developed by FBK in near ultraviolet high density (NUV-HD) technology. The crystal and the SiPM were installed on separated copper frames. The crystal was cooled down by liquid nitrogen, while the SiPM was kept at temperature close to room temperature. A separation of 1 mm was kept between the crystal and the photodetector to ensure thermal isolation. The temperature of the crystal could be varied by heaters on the scintillator frame and was continuously monitored using a coil shaped resistance thermometer. The CsI:T1 scintillation decay profiles were recorded in the entire temperature range provided by the cryostat.
  •  
9.
  • Swiderski, L., et al. (författare)
  • Temperature Dependence of CsI:Tl Scintillation Pulse Shapes from -183°C to +90°C Measured with a SiPM Readout
  • 2018
  • Ingår i: 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2017 - Conference Proceedings. - : Institute of Electrical and Electronics Engineers Inc.. - 9781538622827
  • Konferensbidrag (refereegranskat)abstract
    • A custom designed cryostat was constructed to measure the response of a CsI:Tl scintillator in temperature range from - 183 ^{circ}\mathrm {C} up to +90 ^{circ}\mathrm {C}. The light readout was realized using a SiPM developed by FBK in near ultraviolet high density (NUV-HD) technology. The crystal and the SiPM were installed on separated copper frames. The crystal was cooled down by liquid nitrogen, while the SiPM was kept at temperature close to room temperature. A separation of 1 mm was kept between the crystal and the photodetector to ensure thermal isolation. The temperature of the crystal could be varied by heaters on the scintillator frame and was continuously monitored using a coil shaped resistance thermometer. The CsI:Tl scintillation decay profiles were recorded in the entire temperature range provided by the cryostat.
  •  
10.
  • Söderström, Pär-Anders, 1980-, et al. (författare)
  • Neutron detection and gamma-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 916, s. 238-245
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we present a comparison between the two liquid scintillators BC-501A and BC-537 in terms of their performance regarding the pulse-shape discrimination between neutrons and gamma rays. Special emphasis is put on the application of artificial neural networks. The results show a systematically higher gamma-ray rejection ratio for BC-501A compared to BC-537 applying the commonly used charge comparison method. Using the artificial neural network approach the discrimination quality was improved to more than 95% rejection efficiency of gamma rays over the energy range 150 to 1000 keV for both BC-501A and BC-537. However, due to the larger light output of BC-501A compared to BC-537, neutrons could be identified in BC-501A using artificial neural networks down to a recoil proton energy of 800 keV compared to a recoil deuteron energy of 1200 keV for BC-537. We conclude that using artificial neural networks it is possible to obtain the same gamma-ray rejection quality from both BC-501A and BC-537 for neutrons above a low-energy threshold. This threshold is, however, lower for BC-501A, which is important for nuclear structure spectroscopy experiments of rare reaction channels where low-energy interactions dominates.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy