SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Musso R.) srt2:(2005-2009)"

Sökning: WFRF:(Musso R.) > (2005-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
2.
  • Brignole, M., et al. (författare)
  • Comparative assessment of right, left, and biventricular pacing in patients with permanent atrial fibrillation
  • 2005
  • Ingår i: Eur Heart J. - 0195-668X. ; 26:7, s. 712-22
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Left ventricular (LV) and biventricular (BiV) pacing are potentially superior to right ventricular (RV) apical pacing in patients undergoing atrioventricular (AV) junction ablation and pacing for permanent atrial fibrillation. METHODS AND RESULTS: Prospective randomized, single-blind, 3-month crossover comparison between RV and LV pacing (phase 1) and between RV and BiV pacing (phase 2) performed in 56 patients (70+/-8 years, 34 males) affected by severely symptomatic permanent atrial fibrillation, uncontrolled ventricular rate, or heart failure. Primary endpoints were quality of life and exercise capacity. Compared with RV pacing, the Minnesota Living with Heart Failure Questionnaire (LHFQ) score improved by 2 and 10% with LV and BiV pacing, respectively, the effort dyspnoea item of the Specific Symptom Scale (SSS) changed by 0 and 2%, the Karolinska score by 6 and 14% (P<0.05 for BiV), the New York Heart Association (NYHA) class by 5 and 11% (P<0.05 for BiV), the 6-min walked distance by 12 (+4%) and 4 m (+1%), and the ejection fraction by 5 and 5% (P<0.05 for both). BiV pacing but not LV pacing was slightly better than RV pacing in the subgroup of patients with preserved systolic function and absence of native left bundle branch block. Compared with pre-ablation measures, the Minnesota LHFQ score improved by 37, 39, and 49% during RV, LV, and BiV pacing, respectively, the effort dyspnoea item of the SSS by 25, 25, and 39%, the Karolinska score by 39, 42, and 54%, the NYHA class by 21, 25, and 30%, the 6-min walking distance by 35 (12%), 47 (16%), and 51 m (19%) and the ejection fraction by 5, 10, and 10% (all differences P<0.05). CONCLUSIONS: Rhythm regularization achieved with AV-junction ablation improved quality of life and exercise capacity with all modes of pacing. LV and BiV pacing provided modest or no additional favourable effect compared with RV pacing.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy