Design and manufacture procedures of phantoms for hyperthermia QA guidelines
-
- de Lazzari, Mattia, 1996 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Napieralski, Wojtek (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Nguyen, Thien (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Ström, Anna, 1976 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Dobsicek Trefna, Hana, 1979 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- 2023
- 2023
- Engelska.
-
Ingår i: 17th European Conference on Antennas and Propagation, EuCAP 2023.
- Relaterad länk:
-
https://doi.org/10.2...
-
visa fler...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- Clinical outcome of hyperthermia therapy (HT) is strongly correlated with the thermal dose delivered into the tumor. Achieving of prescribed temperature distribution within the target area should therefore the primary objective of any HT treatment. The Quality Assurance (QA) guidelines developed in past decennium by ESHO-TC establish the physical characterization and prescribe the safeguards to ensure that the clinically used equipment is capable of achieving adequate temperatures. The direct implementation of these guidelines is however limited by the lack of suitable phantom materials. To address this issue, we propose (i) a novel material to mimic fat tissue and (ii) a standardized phantom verification of phased array applicators for deep HT in Head and Neck (H&N) and extremities. In particular, (i) a fat-phantom composed of an ethylcellulose based oleogel exhibit equivalent dielectric and thermal properties with the required mechanical stability even at elevated temperatures, while (ii) the standardized phantom provides the means to capture the thermal profiles to evaluate the performance indicators in reproducible manner. Both phantoms thus bears a great potential for their extensive use in QA procedures.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Modelling
- Hyperthermia
- Quality Assurance