SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Neil Mark A. A.) srt2:(2005-2009)"

Sökning: WFRF:(Neil Mark A. A.) > (2005-2009)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Önfelt, Björn, et al. (författare)
  • Structurally distinct membrane nanotubes between human macrophages support long-distance vesicular traffic or surfing of bacteria
  • 2006
  • Ingår i: Journal of Immunology. - : The American Association of Immunologists. - 0022-1767 .- 1550-6606. ; 177:12, s. 8476-8483
  • Tidskriftsartikel (refereegranskat)abstract
    • We report that two classes of membrane nanotubes between human monocyte-derived macrophages can be distinguished by their cytoskeletal structure and their functional properties. Thin membrane nanotubes contained only F-actin, whereas thicker nanotubes, i.e., those > similar to 0.7 mu m in diameter, contained both F-actin and microtubules. Bacteria could be trapped and surf along thin, but not thick, membrane nanotubes toward connected macrophage cell bodies. Once at the cell body, bacteria could then be phagocytosed. The movement of bacteria is aided by a constitutive flow of the nanotube surface because streptavidin-coated beads were similarly able to traffic along nanotubes between surface-biotinylated macrophages. Mitochondria. and intracellular vesicles, including late endosomes and lysosomes, could be detected within thick, but not thin, membrane nanotubes. Analysis from kymographs demonstrated that vesicles moved in a stepwise, bidirectional manner at similar to 1 mu m/s, consistent with their traffic being mediated by the microtubules found only in thick nanotubes. Vesicular traffic in thick nanotubes and surfing of beads along thin nanotubes were both stopped upon the addition of azide, demonstrating that both processes require ATP. However, microtubule destabilizing agents colchicine or nocodazole abrogated vesicular transport but not the flow of the nanotube surface, confirming that distinct cytoskeletal structures of nanotubes give rise to different functional properties. Thus, membrane nanotubes between macrophages are more complex than unvarying ubiquitous membrane tethers and facilitate several means for distal interactions between immune cells.
  •  
2.
  •  
3.
  • Benninger, Richard K. P., et al. (författare)
  • Live Cell Linear Dichroism Imaging Reveals Extensive Membrane Ruffling within the Docking Structure of Natural Killer Cell Immune Synapses
  • 2009
  • Ingår i: Biophysical Journal. - : Elsevier BV. - 0006-3495 .- 1542-0086. ; 96:2, s. L13-L15
  • Tidskriftsartikel (refereegranskat)abstract
    • We have applied fluorescence imaging of two-photon linear dichroism to measure the subresolution organization of the cell membrane during formation of the activating (cytolytic) natural killer (NK) cell immune synapse (IS). This approach revealed that the NK cell plasma membrane is convoluted into ruffles at the periphery, but not in the center of a mature cytolytic NK cell IS. Time-lapse imaging showed that the membrane ruffles formed at the initial point of contact between NK cells and target cells and then spread radialy across the intercellular contact as the size of the IS increased, becoming absent from the center of the mature synapse. Understanding the role of such extensive membrane ruff ling in the assembly of cytolytic synapses is an intriguing new goal.
  •  
4.
  • McGrath, Patrick J., et al. (författare)
  • Core outcome domains and measures for pediatric acute and chronic/recurrent pain clinical trials : PedIMMPACT recommendations
  • 2008
  • Ingår i: Journal of Pain. - : Elsevier BV. - 1526-5900 .- 1528-8447. ; 9:9, s. 771-83
  • Tidskriftsartikel (refereegranskat)abstract
    • Under the auspices of the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT), 26 professionals from academia, governmental agencies, and the pharmaceutical industry participated in a 2-stage Delphi poll and a consensus meeting that identified core outcome domains and measures that should be considered in clinical trials of treatments for acute and chronic pain in children and adolescents. Consensus was refined by consultation with the international pediatric pain community through announcement of our recommendations on the Pediatric Pain List and inviting and incorporating comments from external sources. There was consensus that investigators conducting pediatric acute pain clinical trials should consider assessing outcomes in pain intensity; global judgment of satisfaction with treatment; symptoms and adverse events; physical recovery; emotional response; and economic factors. There was also agreement that investigators conducting pediatric clinical trials in chronic and recurrent pain should consider assessing outcomes in pain intensity; physical functioning; emotional functioning; role functioning; symptoms and adverse events; global judgment of satisfaction with treatment; sleep; and economic factors. Specific measures or measurement strategies were recommended for different age groups for each domain. PERSPECTIVE: Based on systematic review and consensus of experts, core domains and measures for clinical trials to treat pain in children and adolescents were defined. This will assist in comparison and pooling of data and promote evidence-based treatment, encourage complete reporting of outcomes, simplify the review of proposals and manuscripts, and facilitate clinicians making informed decisions regarding treatment.
  •  
5.
  •  
6.
  • Whale, Mark, et al. (författare)
  • Analysis of two ALMA Front End Receiver Channels using Physical Optics
  • 2008
  • Ingår i: Proc of SPIE, Terahertz Technology and Applications. ; 6893, s. 68930D-1
  • Konferensbidrag (refereegranskat)abstract
    • The Atacama Large Millimetre Array will be a single research instrument composed of up to 50 high precision antennas, located at the Chajnantor plain in the district of San Pedro de Atacama, 5000m above sea level. Each ALMA telescope will contain 10 frequency channels/bands, ranging from 30 to 950GHz. Radiation from the secondary reflector is collected to the receivers of each wavelength channel through their accompanying front end optics. We present a full electromagnetic treatment of the front end optics for band 5 (163 - 211 GHz) and band 9 (602 - 720 GHz). A full quasi optical and physical optics analysis of the band 5 front end optics, using the antenna analysis tool, GRASP9 [1] is presented. Potential optimisation for the system is presented, namely a reflector edge taper and a comparison of two surface geometries. A similar analysis of the band 9 system is presented. Full electromagnetic simulations are compared with cold beam pattern measurements made at the Space Research Organisation of the Netherlands [2, 3]. Analysis of the effect of the polarizing grid is presented, with suggested modifications to improve cross polar levels
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy