SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nemeth Artur) srt2:(2020-2024)"

Sökning: WFRF:(Nemeth Artur) > (2020-2024)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dray, Xavier, et al. (författare)
  • Feasibility and diagnostic yield of small-bowel capsule endoscopy in patients with surgically altered gastric anatomy : the SAGA study
  • 2021
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 0016-5107. ; 94:3, s. 1-597
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy. Methods: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates. Results: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate,.4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%). Conclusions: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.
  •  
2.
  • Elli, Luca, et al. (författare)
  • Nomenclature and Definition of Atrophic Lesions in Small Bowel Capsule Endoscopy : A Delphi Consensus Statement of the International CApsule endoscopy REsearch (I-CARE) Group
  • 2022
  • Ingår i: Diagnostics. - : MDPI AG. - 2075-4418. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • (1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.
  •  
3.
  • Leenhardt, Romain, et al. (författare)
  • Nomenclature and semantic descriptions of ulcerative and inflammatory lesions seen in Crohn’s disease in small bowel capsule endoscopy : An international Delphi consensus statement
  • 2020
  • Ingår i: United European Gastroenterology Journal. - : Wiley. - 2050-6406 .- 2050-6414. ; 8:1, s. 99-107
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In the medical literature, the nomenclature and descriptions (ND) of small bowel (SB) ulcerative and inflammatory (U-I) lesions in capsule endoscopy (CE) are scarce and inconsistent. Inter-observer variability in interpreting these findings remains a major limitation in the assessment of the severity of mucosal lesions, which can impact negatively on clinical care, training and research on SB-CE. Objective: Focusing on SB-CE in Crohn’s disease (CD), our aim is to establish a consensus on the ND of U-I lesions. Methods: An international panel of experienced SB-CE readers was formed during the 2016 United European Gastroenterology Week meeting. A core group of five CE and inflammatory bowel disease (IBD) experts established an Internet-based, three-round Delphi consensus but did not participate in the voting process. The core group built illustrated questionnaires, including SB-CE still frames of U-I lesions from patients with documented CD. Twenty-seven other experts were asked to rate and comment on the different proposals for the ND of the most frequent SB U-I lesions. For each round, we used a 6-point rating scale (varying from ‘strongly disagree’ to ‘strongly agree’). The consensus was reached when at least 80 % of the voting members scored the statement within the ‘agree’ or ‘strongly agree’ categories. Results: A 100% participation rate was obtained for all the rounds. Consensual ND were reached for the following seven U-I lesions: aphthoid erosion, deep ulceration, superficial ulceration, stenosis, edema, hyperemia and denudation. Conclusion: Considering the most frequent SB U-I lesions seen in CE in CD, a consensual ND was reached by the international group of experts. These descriptions and names are useful not only for daily practice and medical education, but also for medical research.
  •  
4.
  • Spada, Cristiano, et al. (författare)
  • AI-assisted capsule endoscopy reading in suspected small bowel bleeding : a multicentre prospective study
  • 2024
  • Ingår i: The Lancet Digital Health. - 2589-7500. ; 6:5, s. 345-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. Methods: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. Findings: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6–19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). Interpretation: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. Funding: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy